| 1 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) as per DSR-2023 S.I No. 6.1.2 |
| 2 | MS or Iron in Plain work in heavy size such as chokhat Trusses, Built up Gates, Door Frame, Grill including drilling holes, riveting, binding for proper shape and including supply of steel & its wastage, bend, hooks, steel bolt, Nuts etc and their fixing and including supply of all material, labour, tools and plants etc required for proper completion of the work. S.I.No. 503 |
| 3 | 12mm thick plaster with cement and coarse sand 2.20 F.M. in 1:4 cement mortar over brick work minimum thickness not to be less than 1 cm. including supply of all material, labour, tools & plants etc required for proper completion of the work. SINo 584 a |
| 4 | 12mm thick plaster with cement and coarse sand 2.20 F.M. in 1:4 cement mortar over brick work minimum thickness not to be less than 1 cm. including supply of all material, labour, tools & plants etc required for proper completion of the work. SINo for rough side |
| 5 | Three coat of Paiting or varnishing work in small area or new wood / iron wok with one coat (upto one square metre of ready mixed ) priming paint and one coat of approved superior quality ready mixed paint or varnish including supply of all material, labour, tools and plants etc required for proper completion of the work. Paint to be used should be conform the ISI No. 109-1950 . SINo 641+642 |
| 6 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface as per DSR 2023 S.I. No -13.80 |
| 7 | 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:With common burnt clay F.P.S.(non modular) brick tile of class designation 10 |
| 8 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per DSR-2023 S.I No. 13.46.1 Two Coats |
| 9 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. as per DSR(E&M)-2022 Sl no.1.10.3 Group-C |
| 10 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.as per DSR(E&M)-2022 Sl no.1.12 |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.as per DSR(E&M)-2022 Sl no.1.31 |
| 12 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.as per DSR(E&M)-2022 Sl no.2.10.1 Single pole |
| 13 | Add 18% Gst Please Enable Macros to View BoQ information |