| 1 | Appendix I-Pucca repair and maintenance to the thidappally |
| 2 | Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 3 | Providing and fixing on roof with 150mm square PVC rain water gutter pipes white including jointing with seal ring and fitting with pathy clamps at 1m interval etc.complete as per the direction of Engineer in charge. |
| 4 | Providing and fixing PVC moulded fittings/ accessories for PVC square rain gutter, including jointing with PVC solvent cement- square central drop (6'') |
| 5 | Providing and fixing PVC moulded fittings/ accessories for PVC square rain gutter, including jointing with PVC solvent cement- Square end drop (6\\") |
| 6 | Providing and fixing single scaffolding system (cup lock type) on the exterior side, upto 15m height made with 40 mm dia M.S. tube, 1.5 m centre to centre, horizontal& vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for workingplatform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. |
| 7 | Providing and fixing false ceiling with 8mm thick non asbestos fibre cement board (V board ) of approved quality in GI/Aluminium alloy frame work with necessary screws etc complete (GI/Aluminium alloy frame work shall be paid separately) |
| 8 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 9 | Supplying M P hip and ridge tiles 400 mm or nearest available size |
| 10 | Supplying Ist class M.P.roofing tiles of size 410 x 235 mm or nearest available size with single groove |
| 11 | Mason IInd class engaged for relaying the dislocated and damaged roofing tile in correct line and level. |
| 12 | Roofing with departmental (old and new) (400mm or nearest available size M.P hip & ridge tiles first class set in CM 1:4 including finishing the edges |
| 13 | Roofing with departmental (old and new) first class MP tiles (size 410X235 mm) or nearest available size |
| 14 | Supplying and fixing Anjily wood wrought and put up for roof members includingcost and conveyance of materials etc. complete . |
| 15 | Supplying and fixing Anjily wood reapers of size 50x25 mm with wire nails including cost and conveyance of materials etc. complete. |
| 16 | Supplying and fixing Dept. wood reapers of size 50x25 mm with wire nails including cost and conveyance of materials etc . complete. |
| 17 | Carpenter IInd class engaged for repairs and maintenance to the old dislocatedwrought and put up including re nailing etc. complete |
| 18 | Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:4:8 or leaner mix ( including equivalent design mix) |
| 19 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 20 | Carpenter IInd class engaged for repairs and maintenance to the doors and windows. |
| 21 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters andunder, including cutting the patch in proper shape, raking out joints and preparing andplastering the surface of the walls complete, including disposal of rubbish to thedumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : finesand) |
| 22 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Oneor more coat applied @ 0.90 ltr/10 sqm). |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade :One or more coats on old work |
| 24 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 25 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 26 | Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work Please Enable Macros to View BoQ information |