| 1 | Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins refixing the same as required. |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.:2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | Supply and fixing of T/W board with sunmica top (Material and Labour complete) of following sizes:8\\"x10\\"x2\\" |
| 4 | Supply and fixing of T/W board with sunmica top (Material and Labour complete) of following sizes:8\\"x6\\"x2\\" |
| 5 | Supply and fixing of T/W board with sunmica top (Material and Labour complete) of following sizes:7\\"x4\\"x2\\" |
| 6 | Supply and fixing of T/W board with sunmica top (Material and Labour complete) of following sizes:4\\"x4\\"x2\\" |
| 7 | Supply and fixing sunmica sheet (Material and Labour complete) of following sizes:8\\"x10\\" |
| 8 | Supply and fixing sunmica sheet (Material and Labour complete) of following sizes:8\\"x6\\" |
| 9 | Supply and fixing sunmica sheet (Material and Labour complete) of following sizes:7\\"x4\\" |
| 10 | Supply and fixing sunmica sheet (Material and Labour complete) of following sizes:4\\"x4\\" |
| 11 | Plug Tap 3 pin 15Amp |
| 12 | 25mm Casing and capping (1\\") |
| 13 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required:63A Isolator (4-pole) |
| 14 | Supplying and fixing 5 A to 32 As rating, 240/415 volts , 10 kA , \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:Triple pole and neutral |
| 15 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required:63 A |
| 16 | Supplying and fixing 5 A to 32 As rating, 240/415 volts , 10 kA , \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:Double pole MCB |
| 17 | Supplying and fixing 5 A to 32 As rating, 240/415 volts , 10 kA , \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:Single pole MCB |
| 18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator):6 Pole, Double door |
| 19 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required:15/16 amp switch (Piano type) |
| 20 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required:6 pin 15/16 amp socket outlet |
| 21 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required:5/6 amps switch |
| 22 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required:3 pin 5/6 amp socket outlet |
| 23 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Aeres in the existing MCB DB complete with connections, testing and commissioning etc. as required:25 A |
| 24 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Aeres in the existing MCB DB complete with connections, testing and commissioning etc. as required:40 A |
| 25 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Aeres in the existing MCB DB complete with connections, testing and commissioning etc. as required:63 A |
| 26 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required:125A, 16KA |
| 27 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required:200A, 25KA |
| 28 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required:400A, 50KA |
| 29 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required:630A, 50KA |
| 30 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:5/6 amps switch (Modular Type) |
| 31 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:3 pin 5/6 amp socket outlet (Modular Type) |
| 32 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:15/16 amp switch (Modular Type) |
| 33 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:6 pin 15/16 amp socket outlet (Modular Type) |
| 34 | Complete rewinding of exhust fan industrial type including dismentling assembling and comissioning of same (Material and Labour complete). |
| 35 | Complete rewinding of Ceiling fan (with old & BLDC fan) including dismentling assembling and comissioning of same (Material and Labour complete). |
| 36 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 37 | Trimming of tree branches and cutting of bushes along lighting snd LT OH line near different service building of Nigahi Project. |
| 38 | Painting and Numbering of Lighting Pole surrounding street light of all service building:Painting with aluminium paint of approved brand and manufacture to given an even shade. Two or more coats. (4.71 Sq mtr X 400Nos. = 1884 SQ mtr) |
| 39 | Painting and Numbering of Lighting Pole surrounding street light of all service building:Lettering with black Japan paint of approved brand and manufacture. (8 cm X 12 latter X 400 pole = 38400 cm) |
| 40 | General Electrical maintenance of mine light and other electrical work in mine area by engagging Two nos. of skilled (01 No. pole fitter & 01 No. light repairing mechanic) and 01 No. of semi skilled menpower with proper tool and required daily in general shift. |
| 41 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |