| 1 | Taking down carefully existing points wiring on surface conduit/ concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of walls, ceiling etc all as specified and directed Engr-in-charge. |
| 2 | M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer in-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. Note:- V- Rate of cutting chasing included in the unit rate quoted for this item |
| 3 | M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light point controlled by 2 way and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed.Note-I- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-II- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -III - cost of Eye/bottle thimbles used for connection for 2 way switch is deemed to be included in the unit rate quoted for this item. Note:-III- Rate of cutting chasing included in the unit rate quoted for this item |
| 4 | All as per Sl item No 02 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. |
| 5 | All as per Sl item No 02 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. |
| 6 | All as per item No.02 here in before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copper earth wire for switch socket combination 3 pin 15 amps on independent board. |
| 7 | M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in existing conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer iin-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. |
| 8 | All as per Sl item No 07 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. |
| 9 | All as per Sl item No 07 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. |
| 10 | All as per item No 07 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copper earth wire for switch socket combination 3 pin 15 amps on independent board. |
| 11 | Supply and fix in replacement of Modular switch 1 way, 6 Amps, 1 module complete all as specified and directed by Engr-in-charge. |
| 12 | Supply and fix in replacement of Modular switch 1 way, 16 Amps, 1 module complete all as specified and directed by Engr-in-charge. |
| 13 | Supply and fix in replacement of Modular switch 2 way, 6 Amps, 1 module complete all as specified and directed. |
| 14 | Supply and fix in replacement of Modular Bell switch 1 way, 6 Amps, 1 module complete all as specified.and directed by Engr-in-charge. |
| 15 | S & F Bell ding dong electronic complete all as specified and directed by Engineer-in-charge. |
| 16 | Supply and fix in replacement of Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed by Engr-in-charge. |
| 17 | Supply and fix in replacement of Modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and directed by Engr-in-charge. |
| 18 | Supply and fix in replacement of Fan regulator modular type 2 module complete all as specified and directed by Engr-in-charge. |
| 19 | Supply and fix in replacement Ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed by Engr-in-charge. |
| 20 | Material and labour for in replacement angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 23 watts for batten fitting, including plastic square board of required size, complete all as specified and directed. |
| 21 | S&F Ceiling/surface mounted Slim design LED round Downlight with Superior light output and internal driver 9/10 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge. |
| 22 | S & F in replacement of MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B curve as directed by engineer in charge) |
| 23 | S & F in replacement of Sheet metal enclosure DB TPN 4 ways double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link flush mounting type, drilling holes for incoming and out going cables complete with IP-43 protection complete all as specified and directed by Engr-in-charge |
| 24 | Supply and fixing LED batten fitting 18-20 watt, 4 feet, PVC housing with electronic driver cool/warm type complete connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 25 | Supply and fixing LED batten fitting 10-12 watt, 2 feet, PVC housing with electronic driver, including LED luminaire 10/12 watt cool/warm type connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | S&F as in repair 9/12 watt LED light fitting wall mounting fixture wooden finish (sketch type) including LED lamp 9 watt compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable light fittings all as specified and as directed by the Engineer-in-Charge. |
| 27 | Supply and fix in replacement of metal flush box of 2 module in MAP qtrs complete all as specified and directed. |
| 28 | Supply and fix in replacement of metal flush box of 3 module in MAP qtrs complete all as specified and directed. |
| 29 | Supply and fix in replacement of metal flush box of 4 module in MAP qtrs complete all as specified and directed. |
| 30 | Supply and fix in replacement of metal flush box of 6 module in MAP qtrs complete all as specified and directed. |
| 31 | Supply and fix in replacement of metal flush box of 8 module in MAP qtrs complete all as specified and directed. |
| 32 | Supply and fix in replacement of modular cover plate of 2 module in MAP qtrs complete all as specified and directed. |
| 33 | Supply and fix in replacement of modular cover plate of 3 module in MAP qtrs complete all as specified and directed. |
| 34 | Supply and fix in replacement of modular cover plate of 4 module in MAP qtrs complete all as specified and directed. |
| 35 | Supply and fix in replacement of modular cover plate of 6 module in MAP qtrs complete all as specified and directed. |
| 36 | Supply and fix in replacement of modular cover plate of 8 module in MAP qtrs complete all as specified and directed. |
| 37 | Material and labour for PCC 1:3:6 type C-2 using 20 mm graded stone aggregate for certain works (filling tha gap around DB VTPN) including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified. |
| 38 | Supply and fixing of inverter LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with 4 hours battery back up all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light with GI bracket of suitable size and clamps with fixing accessories including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.Make: Halonix cat ref no LED SL 30W HLSLD-ML04-30-CWL-INV-RTC-R or as equivalent in Havells/Philiphs/Crompton |
| 39 | Supply and fixing of Inverter LED tube light fitting 1x20 Watt with minimum 04 hours battery back integrated aluminium batten with diffuser and including 20 Watt LED hight efficient, AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 40 | S & F LED lamp invertor technology 9 watt with 4 hour power back up with efficiency more than 100 lumen per watt, Lithium ion battery including removing of unserviceable lamp complete all as specified and directed by Engr-in-charge. |
| 41 | Material & labour for replacement of unsv earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth strip protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . |
| 42 | Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty, 2 core, 10 sq mm nominal cross section cable with PVC insulated aluminium conductor multistrand served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old unserviceable existing cable complete all as specified and as directed by the Engineer-in-Charge. |
| 43 | Supply and fixing concrete pit in PCC (1:3:6) type C1 of size 40x40x40 cm having hollow inner space 30 cm, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar complete all as specified and directed by Engr-in-Charge. |
| 44 | Material and labour for servicing of earthing on site including filling water, GI funnel, minor plaster work if necessary, white wash complete all as specified and directed. |
| 45 | Checking of earthing results of various type of earthing installed in bldgs/Sub station through earth test meter and submission of earthing report complete all as specified and directed by Engr-in-charge. |
| 46 | Supply only PVC rigid casing caping 20 mm dia icl fixing clamps complete all as specified and directed by Engr-in-Charge. |
| 47 | Supply and fixing hot pressed module SMC meter junction boxes SMC base and SMC door, concealed hinges, veiwing glass, earth bolt, plugged off white colour suitable for single phase energy meter complete all as specified and directed. |
| 48 | Supply and fix in replacement epoxy power coated MCCB distribution distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with common bus-bar rated 200 Amp at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth (iii) Connection of cable with VTPN shall be done through appropriate size of Al thimble. |
| 49 | Supply and fix in replacement of MCCB, 4 Pole, 100 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge. |
| 50 | Supply and fix in replacement of MCCB, 4 Pole, 125 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge. |
| 51 | Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge. |
| 52 | Supply and fix in replacement of Sheet metal enclosure 4 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge. |
| 53 | S & F in replacement of MCB , SPN, 240 Volts ,63 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge) |
| 54 | S & F in replacement of MCB , SPN, 240 Volts ,40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge) |
| 55 | S & F in replacement of MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B curve as directed by engineer in charge) |
| 56 | S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'B' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. |
| 57 | M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia medium grade including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia medium grade with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 58 | M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.0 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 59 | M & L for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 1.5 sq. mm main cable + 1 run of 1.5 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item. |
| 60 | M & L for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 2.5 sq. mm main cable + 1 run of 2.5 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item. |
| 61 | Supply and fix in replacement of New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07, with all accessories including suitable bracket with 32 mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge. |
| 62 | Supply and fixing in replacement of LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, IP 66, PVC housing, surge protection including driver & LED lamp etc complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |