| 1 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 2 | Group-C |
| 3 | DSR Item No. 1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | Group-C |
| 5 | DSR item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 6 | DSR item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 7 | DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 8 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 1.5 sq. mm |
| 10 | 3 x 2.5 sq. mm |
| 11 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | DSR item No.1.27Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 13 | 4 Module (125 mmX75 mm) |
| 14 | 8 Module (125 mmX125 mm) |
| 15 | 12 Module (200 mmX150 mm) |
| 16 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 17 | DSR Item No. 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 18 | DSR item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 19 | 5/6 amps switch |
| 20 | 3 Pin 5/6 A. socket outlet |
| 21 | DSR item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 22 | DSR item No.1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 23 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Single pole |
| 25 | DSR Item No. 8.6.10LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, (As per Complete Item No. 15 of the DNIT). |
| 26 | 36 Watt |
| 27 | DSR ITEM NO. LED 8.9.5Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,(As per Complete Item No. 16 of the DNIT). |
| 28 | 18-22 watt |
| 29 | DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, (As per Complete Item No. 17 of the DNIT). |
| 30 | 12 way (4 + 36), Double door |
| 31 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Complete Item No. 18 of the DNIT). |
| 32 | Size 15” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 33 | Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. (As per Complete Item No. 19 of the DNIT). |
| 34 | DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 35 | 100 A,36KA,FPMCCB |
| 36 | Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The make should be Super Hylam / Formica / GreenLam only. |
| 37 | Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. (As per Complete Item No. 22 of the DNIT). |
| 38 | 50 Sq.mm. 3.5 Core PVC Armoured Aluminium conductor cable |
| 39 | Supply & erection of Cabin Fan 16\\" sweep (metal body) oscillating type complete with aluminium blades & regulator. The fan should have regulator switch for speed regulation. The fan should be of Havells make V3/Crompton make Strom2/ Orient make Tornado-II only. (As per Complete Item No. 23 of the DNIT).Charge. Please Enable Macros to View BoQ information |