| 1 | Demolition of cement concrete in ground floors , pavings, sunken floor n exc 15 cm thickness etc (below or above ground level) and rubbish off from the premises complete all as specified and as directed. |
| 2 | M & L 100 mm thick cement concrete (1:4:8) type D2 (using 40mm grade broken stone aggregate) as in sub base complete all as specified and as directed. |
| 3 | M&L for Machine cut kota stone 20-25mm thick over cement screed bed 20mm thick in CM (1:4) laid and jointed with grey cement slurry and pointed with grey cement and pigment to match the shade of the slab including rubbing and polishing complete (mirror polish) as in flooring/steps /slabs complete all as specified and as directed. |
| 4 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness, as in roof coverings complete all as specified and as directed. |
| 5 | Dismentling structual steel work including doors, gates but excluding framed trusses etc complete all as specified and as directed. |
| 6 | Supply and fix for Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. conforming Fe 410-W(Gde-E-250) quality -B complete all as specified and as directed. |
| 7 | M&L for mild steel framed work such as grill, gate etc with ends of bars shouldered or rebated or forged into spike framed guard bars barred iron doors, ladders, framed baluster, walk way, railing; frame work, including pintle hinges, stops, hand-made sliding bolts etc,sliding channels for sliding of gate and similar work conforming to Fe 290 Gde-E-165 complete all as specified & as directed. |
| 8 | M & L for preparation of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 9 | M & L for preparation of old steel surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel complete all as specified and as directed. |
| 10 | Supply and fix for 0.50mm thick Arch type Bend to a curve (Any radius/shape) pre-painted galvalume aluminium zinc coating (AZ-150) GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws with two corrugation side lap complete all as specified and as directed. |
| 11 | Supply and fix for 0.60mm thick pre-painted galvalume aluminium zinc coating (AZ-150) GI based plain/corrugated steel sheet of any colour Use in valigator having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws with two corrugation side lap complete all as specified and as directed. |
| 12 | Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded broken stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement including demolition complete all as specified and as directed. |
| 13 | Dismantiling of interlocking tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed. |
| 14 | M & L for Machine pressed precast concrete interlocking paver block rubber moulded glossy finish with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and as directed |
| 15 | M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 16 | M&L for Filleting in any position and to any shape in cement mortar 1:4 exc.25 but n exc.50 sq.cm including all mitres, stops, etc. complete all as specified and as directed. |
| 17 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed |
| 18 | M&L for 15mm thick plastering in CM 1:4 on brick or concrete wall surfaces etc finished even and fair all as specified and directed. |
| 19 | M&L for preparation of newly/old plastered surfaces and applying two coats of weather proof exterior emulsion paint ('APEX' brand of Asian or equivalent brand of Berger/Shalimar) over one coat of primer to wall complete all as specified and as directed by Engineer-in-charge. |
| 20 | Material and labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit including all accessories, Metal flush box of suitable module, with earth dolly, covered with modular white cover plate & frame after chasing in brick / stone masonry walls etc for accomodating modular switches, sockets, regulators etc including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed for the following :-One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board |
| 21 | Description all as per 20 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point,16 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed |
| 22 | Supply and fixing Modular Switch - 6 Amps, Single pole one way, one module complete all as specified and as directed. |
| 23 | Supply and fixing Modular Switch - 16 Amps, Single pole one way, one module complete all as specified and as directed. |
| 24 | S & F Modular socket outlet multipurpose 6 Amps, 5 pin, 2 module, complete all as specified and as directed. |
| 25 | S & F Modular socket outlet multipurpose 16 Amps, 6 pin-shuttered type, 2 module, complete all as specified and as directed. |
| 26 | Supply and fixing of next generation, energy saving, environment friendly and robust High bay LED light fitting with pressure die cast (PDC) aluminium housing, suitable for surface or suspended mounting on ceiling, complete with high efficiency LED module having system efficacy upto 150 lumens per watt, integrated electronic LED driver, heat sink, diffuser/reflector, necessary mounting accessories, internal wiring, connectors and connection to existing wiring, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 28 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 29 | Supply and fixing 415V 10KA 'C' curve TPN 40 To 100 AMP current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed. |
| 30 | S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed |
| 31 | S & F sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed |
| 32 | S & F submain wiring with two single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 2.5 Sqmm and one single core 2.5 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealed in stone masonary PVC conduit and conduit accessories heavy duty ISI marked, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed all as specified and as directed complete all as specified and as directed. |
| 33 | S & F submain wiring with two single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 4.0 Sqmm and one single core 4.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealed in stone masonary PVC conduit and conduit accessories heavy duty ISI marked, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed all as specified and as directed complete all as specified and as directed. |
| 34 | Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductors 1100 volts grade of size 4 core x 16 Sqmm laid in trenches, fixed on wall etc complete all as specified and directed. |
| 35 | Supply and fixing 25 mm dia rigid PVC conduit pipe (heavy duty) of approved make such as Polycab or equivalent, ISI marked and conforming to IS 9537 Part 3, complete with all accessories including bends, tees, junction boxes, couplers, saddles, inspection boxes etc., fixed on wall/ceiling or concealed in wall including cutting chases, making good plaster and painting to match the existing surface, complete in all respects and as directed by Engineer-in-Charge. |
| 36 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 37 | Taking down carefully aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall by plastering disturbed surface smooth by applying two coats of same colour paint as existing, floor etc. complete all as specified and as directed. |
| 38 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces by plastering disturbed surface smooth by applying two coats of same colour paint as existing to match with the existing finishes all as specified. |
| 39 | Taking down the existing unserviceable sub main wiring of any type / description as existing at site including making good the disturbed surfaces by plastering disturbed surface smooth by applying two coats of same colour paint as existing to match with the existing finishes all as specified. |
| 40 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. Please Enable Macros to View BoQ information |