| 1 | M&L preparation of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc, and brushing neat cement slurry with 3 Kg of cement per square metre and including screed bed or bedding layer 10 mm thick in CM 1:4 for laying floor finishes finished even and smooth without using extra cement with WPC complete all as specified and directed.NOTE: Supply only WPC shall be measured and paid separately. |
| 2 | M&L PCC 1:2:4, type B0 (12.5 mm graded stone aggregate) as in padding, benching & filletting with WPC and including demolition complete all as specified and directed. NOTE: Supply only WPC shall be measured and paid separately. |
| 3 | Taking down cement plaster on wall of any description and including racking out joints for key, scrubbing with water etc, complete all as specified and directed. |
| 4 | M&L brick work with sub-class `B' bricks, straight or curved on plan exc. 6 m mean radius built in CM 1:6 and including demolition complete all as specified and directed. |
| 5 | M&L 15 mm thick rendering in CM 1:4 on concrete or brick wall surfaces, finished even and smooth without using extra cement, mixed with WPC as per manufactuers instrutions complete all as specified and directed.NOTE: Supply only WPC shall be measured and paid separately. |
| 6 | Supply only integral water proofing compound complete all as specified and directed. |
| 7 | Supplying and applying single component AP Smart care PU Magnum, Zero VOC, elastomeric pure polyurethane membrane free from bitumen and tar, APL Smart Care PU Magnum with minimum elongation of 350%, solid content of 85%, Tensile strength of > 2.5 Mpa, crack bridging capacity of 3 mm and shore hardness of > 60. The system consists of applying the PU magnum US waterproofing treatment @ 2 kg/sqm in two coats over a coat of primer with solvent based HFP 130 / 120 / equivalent @ 200 Gms / Sqm and including taking down existing roof treatment of any description completely and removing all the debris from the site and rubbish off the premises, cleaning the entire surface with grinding and removing the loose mortar, dust particles & making the surface sound enough, addressing the cracks by making v groove & if any surface imperfections are treated with APL SC repair polymer mixed with neat cement in 1:1 and including the following complete all as specified and directed :- |
| 8 | Treating all construction joints, coving / angle fillet: The coving shall be done on all sharp edges and on the terrace surface to avoid water stagnation. The coving of size (50 mm x 50 mm) should be done by smart care repair polymer mixed @ 5% of weight of cement in 1:4 ratio of cement and sand across the joints area of slab and parapet wall, bore packing all the pipes are made rough by applying a bond coat with APL smart care multi-purpose polymer along the periphery of the pipe and sand sprinkling over, pipes to be placed inside the core cut areas appropriately. Grouting the gaps between the pipes and core cut by smart care general purpose grout after fixing an effective leak free shuttering. |
| 9 | S&F 110 mm bore PVC (SWR ) pipes single socketed, in any length with rubber ring joints as in rain water, soil, waste and vent pipe (with all fittings) fixed to wall and including taking down complete all as specified and directed. |
| 10 | S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of hoisted and fixed in position and including dismantling complete all as specified and directed. |
| 11 | All as per Sl. Item No. 9 above but 1000 litres |
| 12 | All as per Sl. Item No. 9 above but 2000 litres |
| 13 | S&F in repairs 20 mm dia brass ball valve, high pressure with polythene float and fly nut complete , screwed for iron pipe or brass ferrule complete all as specified and directed |
| 14 | All as per Sl. Item No. 12 above but 25 mm dia |
| 15 | S&F in repairs 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 16 | All as per Sl. Item No. 14 above but 25 mm dia |
| 17 | S&F in repairs 20 mm bore GI tubing medium grade with all fittings fixed to wall / ceiling or in floor complete as specified and directed. |
| 18 | All as per Sl. Item No. 16 above but 25 mm bore |
| 19 | All as per Sl. Item No. 16 above but 40 mm bore |
| 20 | M&L pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws and including dismantling complete all as specified and directed |
| 21 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed |
| 22 | S&F MS framed angle sections as in posts, main and cross beams, hip and jack rafters; purlins where connected to common rafters and drilling holes for existing wooden / steel angle rafter; fixed with angle cleats MS screw bolts necessary welding to purlins or other connecting plate of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed. |
| 23 | M&L preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth, not otherwise described and including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 24 | M&L preparation of new plastered wall surfaces and including applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 25 | M&L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick with grey cement and pigment, machine pressed, set jointed and pointed in neat cement slurry in floors and including 15 mm thick screed bed in CM 1:6 and dismantling complete all as specified and as directed. |
| 26 | M&L PCC 1:5:10, type E2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. Please Enable Macros to View BoQ information |