| 1 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering ,and removing surplus soil to a distance n exc 50 m and making good surface in soft /loose soil complete all as specified and directed. |
| 2 | M&L for cement concrete 1:3:6 (Type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 3 | M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 4 | M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 5 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring,etc, and making good, cutting n.exc 10 cm girth in Brick walls complete all as specified and directed. |
| 6 | S&F for prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 7 | M&L for preparation of new steel surface of any description, not otherwise described, over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 8 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 9 | M&L for 100mm thick PCC type D2 1:4:8 (40 mm graded stone aggregate) as in sub basecomplete all as specified and directed. |
| 10 | M&L for 50 mm thick sand cusioning complete all as specified and directed. |
| 11 | M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigments confirming to IS 15658-2006 of 60 mm thickness complete all as specified and directed. |
| 12 | M&L for providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 13 | Taking down carefully aluminium / copper point wiring (light, fan, socket, powerpoint) including batten, conduit and fittings such as switches, ceiling rose, sockets, brackets, light fittings, switch board etc removing, making good distrubed surfaces of wall, floor, ceiling etc complete all as specified and directed. |
| 14 | M&L for point wiring with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor (FRLS) 1100 Volts grade cable (red colour cable to be used for phase connection and black colour cable to be used for neutral connection) including PVC concealed conduit medium grade with all accessories including 1.5 sqmm copper multistrand conductor (FRLS) 1100 Volts grade unsheathed PVC insulated (green colour) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover incl cutting chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed for the following:- Note: Cutting and chasing deemed to be included in coated rate. |
| 15 | Light/Fan/Exhaust fan/Bell point |
| 16 | 5 amp socket on same boared |
| 17 | 5 Amp switch socket on Independent Board. |
| 18 | All as per item No 14.00 here in before but 4.0Sqmm PVC insulated un sheathed cable with stranded copper conductor for 5 pin 6/16 Amp switch socket combination on independent board complete all as specified and directed. |
| 19 | S&F for socket only 3 pin, 5 Amps flush type 230/240 V complete all as specified and directed. ( For same Board only) |
| 20 | S&F for switch socket combination 2 in 1, 5/6 Amps flush type230/240 V complete all as specified and directed. ( For Independent Board only) |
| 21 | S&F for switch socket combination 3 pin, 15/16 Amps flush type 230/240 V complete all as specified and directed. |
| 22 | S&F for ceiling rose 3 phase/PVC/polycarbonate,isolated body,surface type with ISI marked complete all as specified and directed. |
| 23 | S&F for switch piano flush type 5/6 amps , 240 volt single pole one way complete all as specified and directed. |
| 24 | S&F for step type electronic fan regulator flush type 230 volt 5 speed control and connecting up and fix position complete all as specified and directed. |
| 25 | S&F for bell push piano flush type, 5/6 amps, 240 volt, single pole complete all as specified and directed. |
| 26 | S&F for buzzer/ ding dong bell, AC 230 volt, single pole complete all as specified and directed. |
| 27 | S&F in repair of wall decorative ultra slim LED 18/20 Watt, 230 volts, 50 Hz, 4 feet, lighting fixture with extruded polycarbonate lighting fixture, environmental friendly, energy efficient ready to use pack including lamp complete all as specified and directed. Make : Crompton Cat Part No TCS-109-20-65-SL-DP-NWH. |
| 28 | S&F in repair of ultra slim LED batten 10 Watt, 230Volts, 50 Hz, decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly including lamp, connection wire complete all as specified and directed. Make : Crompton Cat Part No TCS-109-10-65-SL-DP-NWH. |
| 29 | S&F for LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make : Crompton Cat Part No CCR-122-36-57-SL-MWS-DP-NWH. |
| 30 | Taking down old serviceable LED light of any type and refixing it in its original or new location complete all as specified and directed. |
| 31 | S&F for building security light LED type of minimum 3500 Lumens (35watts) pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twisted copper conductor cable of suitable size including bracket made of 32mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and directed. Make : Crompton Cat Part No ERP-427-25-57-HL2-LM-NBK. |
| 32 | S&F in repair of factory made sheet metal enclosure for DBs double door, TPN, 415 volt, 4 Way, IP-42 protection with bus bar, neutral link, earth link complete all as specified and directed. |
| 33 | S&F in repair of factory made sheet metal enclosure for DBs double door, SPN, 240 volt, 8 Way, IP-42 protection with bus bar, neutral link, earth link complete all as specified and directed. |
| 34 | S&F in repair of factory made sheet metal enclosure for DBs double door, SPN, 240 volt, 4 Way, IP-42 protection with bus bar, neutral link, earth link complete all as specified and directed. |
| 35 | S&F in repair of 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 10 to 32 Amp current carrying capacity complete with connection testing complete all as specified and directed. |
| 36 | S&F in repair of 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32-40 Amp current carrying capacity complete with connection testing complete all as specified and directed. |
| 37 | S&F in repair of 240V, 10KA 'C' curve miniature circuit breaker (MCB) TPN 63 Amp current carrying capacity complete with connection testing complete all as specified and directed. |
| 38 | S&F in replacement of Factory made sheet metal enclosure for VTPN DBs double door (Fixed flush to the wall), suitable for 125 Amps MCCB as incommer & outgoing as TPN 415 volt, 4 Way, IP-43 protection with 200 Amp rated bus bar and 4.0Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified and directed.Note :- MCCB/MCB will be paid separately under individual item of this schedule. |
| 39 | S&F in repair of sheet metal enclosure, single pole and neutral with two pin and earth plug and socket, 20 Amps, 230 Volts, 50 Hz complete with one single pole MCB of 20 Amps, 10kA, 230 volts, 50Hz, C curve type complete all as specified and directed. |
| 40 | M&L in repair for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through & including medium grade concealed PVC conduit complete all as specified and directed. |
| 41 | M&L in repair for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through & including medium grade concealed PVC conduit complete all as specified and directed. |
| 42 | M&L for sub main wiring with 4 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through & including PVC casing-caping medium grade complete all as specified and directed. |
| 43 | S&F in repair of 415V 16KA curve MCCB TPN 125 Amps current carrying capacity complete with connection testing complete all as specified and directed. |
| 44 | M&L for earthing complete with GI plate electrode 600x600x6.3mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with Galvanize earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion. Material and labour laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. Please Enable Macros to View BoQ information |