| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed by Engineer-in-charge. |
| 2 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge. |
| 3 | S&F pre-painted galvalume aluminium zinc coating GI baesd plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge. |
| 4 | M & L for water proofing treatment with the following specifications including taking down existing roof treatment of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises, complete all as specified and directed by Engineer-in-charge and as per manufacturers instructions:- (i) Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compouund @ 3% by weitht of cement as leveling course (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5 Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iv) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane.Note :- Water proofing compound shall be measured and paid separately. |
| 5 | Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets all as specified and directed by Engineer-in-charge. |
| 6 | M&L for false ceiling with aluminium grid work (size of grid 605x605mm) with 35x25x1.5mm main tee and 25x25x1.4mm, cross tee and wall angle Hangers 6mm dia. G.I (upto 1200mm length) adjusting level fixed to roof slabs means of ceiling cleats made out of G.I flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by Engineer-in-charge. |
| 7 | S&F in repair for Eco board 605 X 605 X 4mm thick fixed in aluminium frame work with screws or nails etc complete all as specified and directed by Engineer-in-charge. |
| 8 | M&L Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) in roof kerbs, mud stops or chamfered on edges all as specified and directed by Engineer-in-charge. |
| 9 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed by Engineer-in-charge. |
| 10 | S & F coloured joint free non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc. set, jointed and pointed in white or coloured cement to match over screed bed in cement mortar 1:4, 15 mm thick, complete all as specified and directed by Engineer-in-charge. |
| 11 | S & F coloured joint free non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set, jointed and pointed in white or coloured cement to match over screed bed in cement mortar 1:4, 15 mm thick, all complete all as specified and directed by Engineer-in-charge. |
| 12 | S & F coloured glazed ceramic tiles 450 mm x 300mm x 7mm to 8mm thick on vertical surfaces such as skirting & dados etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces etc including backing coat of 10mm thick CM 1:3 all as specified and directed by Engineer-in-charge. |
| 13 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any motar all as specified and directed by Engineer-in-charge. |
| 14 | M & L for granite slab 20 mm thick as in cooking platforms, bedded 20mm thick ,in cement mortor 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and directed by Engineer-in-charge. |
| 15 | Material & labour for designer coloured chequred cement concrete tiles of size 20cm x 20cm x 25mm with jointed and pointed in neat cement slurry with grey cement and pigment to match the shade including screed bed 20mm in CM (1:4) all complete all as specified and directed by Engineer-in-charge. |
| 16 | Taking down cement plaster of any description from wall/ceiling including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer-in-charge. |
| 17 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement. |
| 18 | M&L rendering 5mm thick in CM 1:4 with using water proofing compound over 10mm thick in CM 1:6 on external surfaces of block masontry even and smooth without using extra cement.(WPC shall be added in only 5mm thick top layer of plaster @ 2% of cement content) |
| 19 | Supply only integral water proofing compound. |
| 20 | M&L for rendering 5 mm thick in CM 1:3 finished even and smooth without using extra cement on ceiling including applying of cement slurry 3 kg/sqm all as specified and directed by Engineer-in-charge. |
| 21 | M & L for two coats of OBD over a coat of primer on newly plastered surfaces of walls including nesessary preparation of surfaces and scaffolding etc all complete all as specified and directed by Engineer-in-charge. |
| 22 | M&L for two coats of weather coat(Exterior) all guard emulsion, any colour/tined to new wall surfaces over a coat of antifungal primer including necessary preparation of wall surfaces and scaffolding complete all as specified and directed by Engineer-in-charge. |
| 23 | M & L for two coats of OBD over a coat of primer on newly plastered surfaces of ceiling including nesessary preparation of surfaces and scaffolding complete all as specified and directed by Engineer-in-charge. |
| 24 | M & L for preparing old decorated surfaces of ceiling and applying two coats of OBD over a coat of primer all complete all as specified and directed by Engineer-in-charge. |
| 25 | M & L for two coats of OBD over one coat of 1 mm wall care putty on old plastered surfaces of walls including removing existing treatment complete all as specified and directed by Engineer-in-charge. |
| 26 | M& L for two coat of weather proof exterior acrylic emulsion paint with anti fungal property over a coat of primer on old plastered wall surfaces including preperation of surfaces etc complete all as specified and directed by Engineer-in-charge. |
| 27 | M&L for preparation of old wood surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-charge. |
| 28 | M&L for preparation of old steel surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-charge. |
| 29 | Taking down chowkats or frames with shutters area n.exc 1.5 Sqm each(without taking off shutters from the frame) all complete all as specified and directed by Engineer-in-charge. |
| 30 | All as per Item No.29 above but area exc 1.5 Sqm but n.exc 4.00 Sqm. |
| 31 | S & F 30 mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. complete all as specified and directed by Engineer-in-charge in SSR Part I, Section 8, clause 8.24 (a).all as directed by Engr-in-Charge.Note :- Glass/Wire mesh shall be measured and paid separately |
| 32 | S & F Aluminium anodised frame for doors, windows, ventilators with one or more rebates incl joining cleat for fixing etc complete all as specified and directed by Engineer-in-charge. |
| 33 | S&F Aluminium anodised door shutters, aluminium section weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specifed and directed by Engineer-in-charge. |
| 34 | S&F Aluminium anodised window and ventilator shutters, side hung type without sash bar, aluminium section weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 Nos), hinges type B-21 100mm long (2 Nos) suitable handle (1 no) complete all as specified and directed by Engineer-in-charge. |
| 35 | S&F 4 mm thick ACP board (Aluminium Composite Panel ) fixed to aluminium frames complete all as specified and directed by Engineer-in-charge . |
| 36 | S&F 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-charge. |
| 37 | S&F 4mm thick figured glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-charge. |
| 38 | S&F aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and directed by Engineer-in-charge. |
| 39 | S&F in repair aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and directed by Engineer-in-charge. |
| 40 | S&F solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing in SSR complete all as specified and directed by Engineer-in-charge and directed by Engineer -in-Charge. |
| 41 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC `C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing in SSR complete all as specified and directed by Engineer-in-charge . |
| 42 | S&F 75mm Size Butt hinges type C-21 , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed |
| 43 | S&F 100mm Size Butt hinges type B-21 , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed |
| 44 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section. |
| 45 | S & F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section. |
| 46 | S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. |
| 47 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 48 | S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 49 | S&F 140mm long door stopper of aluminium alloy body and tounge, anodised with hard drawn steel spring fixed in floor complete all as specified and directed by Engineer-in-charge. |
| 50 | S&F in repairs 75mm Size Butt hinges type C-21 , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed |
| 51 | S&F in repairs 100mm Size Butt hinges type B-21 , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed |
| 52 | S & F in repairs 150 mm long Aluminium, anodised, barrel tower bolts of extruded section. |
| 53 | S & F in repairs 100 mm long Aluminium, anodised, barrel tower bolts of extruded section. |
| 54 | S&F in repairs Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. |
| 55 | S & F in repairs 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 56 | S & F in repairs100 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 57 | Taking up or down 25mm dia bore steel tubing galvanised and connections complete all as specified and directed by Engineer-in-charge. |
| 58 | Taking up or down 20mm dia bore steel tubing galvanised and connections complete all as specified and directed by Engineer-in-charge. |
| 59 | Taking up or down 15mm dia bore steel tubing galvanised and connections complete all as specified and directed by Engineer-in-charge. |
| 60 | Supply and laying 15mm external dia CPVC pipes SDR11 including Plain UPVC fittings SDR11 mean fittings which do not have any metal component and is jointed with CPVC solvent cement only (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End plugs, etc) & Special fittings include CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor, etc), Unions, Ball valves, Flange and tank adaptor as on walls/ceiling/floors complete all as specified and directed by Engineer-in-charge. |
| 61 | All as per item No. 60 above but 20mm bore. |
| 62 | All as per item No. 60 above but 25mm bore. |
| 63 | S&F in repair 20mm dia Gun metal globe or gate valve with iron wheel head, screwed both end for iron pipe. |
| 64 | S&F for 25mm dia ball brass valves, high pressure, with polythen float and flynut complete, screwed for iron pipe or brass ferrule . |
| 65 | S & F in repair PVC flushing cistern 10 litres capacity syphonic action type, low level, white with inlet, ball valve, float, handle and flush pipe, etc complete all as specified and directed by Engineer-in-charge. |
| 66 | S&F in repairs Brass Chromium plated shower rose 125mm size, with swivel joint, fixing to steel pipe or union, complete all as specified and directed by Engineer-in-charge. |
| 67 | Supply and fix in repairs Bib tap, cast copper alloy chromium plated,15 mm dia with fancy type screwed down for iron pipes or brass ferule etc, complete all as specified and directed by Engineer-in-charge. |
| 68 | S & F in repairs angular stop cock, cast copper alloy chromium plated, 15 mm dia screwed down high pressure, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge. |
| 69 | All as per item No. 68 above, but fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge. |
| 70 | S & F in repairs fancy type, Pillar taps , cast copper alloy , with capstan heads , chromium plated , screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm and fixed all complete all as specified and directed by Engineer-in-charge. |
| 71 | S & F in repairs sink with drainage board, made up of stainless steel, 1mm thick for kitchen or laboratory with plug washers and waste fittings, including bedding in cement mortar 1:3 into dwarf wall or cantilever brackets and connecting union to pipe, over all size 915mm x 460mm, bowl size 410 x 330 x 160mm etc, complete all as specified and directed by Engineer-in-charge. |
| 72 | S&F in repair vitreous china wash hand basin white flat back size 630x450mm incl brackets, PTMT coupling, 32 mm GI pipe waste pipe complete all as specified and directed by Engineer-in-charge. |
| 73 | S & F in repair PVC waste pipe, 32/40mm dia, for WHB & Sink, complete all as specified and directed by Engineer-in-charge. |
| 74 | S&F in repairs brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-charge. |
| 75 | S&F in repairs stainless steel gratings 125mm dia, complete all as specified and directed by Engineer-in-charge. |
| 76 | S&F PVC connection both end brass union 15 mm dia & check nuts of length 450 mm long. |
| 77 | S & F in repairs Mirror of selected quality glass 600 mm x 450 mm bevelled edge mounted on 6 mm thick PVC sheet backing including aluminium beading fixed with wooden plugs and CP brass screws & cup washers complete all as specified and directed by Engineer-in-charge. |
| 78 | S & F in repairs vitreous china squatting pan, Orissa pattern size 630X450 mm white with integral foot rest (excluding flushing cistern) including 'P' or 'S' trap etc complete all as directed by Engineer-in-charge.. |
| 79 | S&F in repair vitreous china EWC white including flush pipe, seat cover etc, including connection to drain (or out going pipe) and to flushing pipe anti syphonage pipes etc complete all as specified and directed by Engineer-in-charge. |
| 80 | S & F rotational moulded polythelene water storage tanks ISI marked (cylindrical vertical with closed top) of 500 Ltrs capacity with tank cover (top), hoisted and fixed in position, including taking down existing tank with all connections complete all as specified and directed by Engineer-in-charge. |
| 81 | S & F rotational moulded polythelene water storage tanks ISI marked (cylindrical vertical with closed top) of 1000 Ltrs capacity with tank cover (top), hoisted and fixed in position, including taking down existing tank with all connections complete all as specified and directed by Engineer-in-charge. |
| 82 | Dismantling of CI drain pipes,50-100 mm dia jointed in cement mortar including all fittings joints etc complete all as specified and directed by Engineer-in-charge. |
| 83 | M&L for PVC (SWR) pipes 110mm bore double socketed in any length with rubber ring joints, fixed to wall incl testing of pipe etc complete all as specified and directed by Engineer-in-charge. |
| 84 | All as per item No. 83 above but 75mm bore of pipe all as specified and directed by Engineer-in-charge. |
| 85 | M&L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm outer dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed by Engineer-in-charge. |
| 86 | Supply and fix PVC (SWR) bends 110mm bore with oval access doors all as specified and directed by Engineer-in-charge. |
| 87 | S&F PVC (SWR) bends 75mm bore with oval access doors complete all as specified and directed by Engineer-in-charge. |
| 88 | S&F PVC (SWR) junction single, (Single T) 110mm bore, equal or unequal with oval access doors all complete all as specified and directed by Engineer-in-charge. |
| 89 | All as per item No. 88 above but 75mm bore of pipe complete all as specified and directed by Engineer-in-charge. |
| 90 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal110mm bore, equal or unequal with oval access doors complete all as specified and directed by Engineer-in-charge. |
| 91 | All as per item No. 90 above but 75mm bore of pipe all complete all as specified and directed by Engineer-in-charge. |
| 92 | Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) all complete all as specified and directed by Engineer-in-charge. |
| 93 | M&L for PCC 1:3:6, type C2, (Using 40 mm graded stone aggregate), 75mm thick as in plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed by Engineer-in-charge. |
| 94 | M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 30 mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m, complete all as specified and directed by Engineer-in-charge. |
| 95 | M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 30mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1 Ltr SBR + 1 Ltr) water + 3 kg cement), complete all as specified and directed by Engineer-in-charge. |
| 96 | M&L for removing loose and broken concrete by chiselling, /picking etc upto a depth of 50 to 100mm from column/ beams and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m, complete all as specified and directed by Engineer-in-charge. |
| 97 | M&L for applying one coat of anti corrossive primer @ 0.25 Lit/Sqm for the steel area to exposed old and new reinforcement to the full circumfrance and length of bars to form unbroken 40 Micron thick film all complete all as specified and directed by Engineer-in-charge . |
| 98 | M&L for applying one coat epoxy bonding agent @ 2.6 sqm/lit or as per manufacture’s instruction to old concrete surfaces of columns, beams and similar structural members all complete all as specified and directed by Engineer-in-charge. |
| 99 | M&L for non shrink, cementitous micro concrete mixed with 12.5 graded stone aggregate using Renderoc RG or equivalent by weight (18 Kg Aggregate : 25 Kg Renderoc RG) respectively (as per manufacturer’s instruction) laid in average thickness 80 to 100 mm in surface, including necessary watertight form work complete all as specified and directed by Engineer-in-charge. |
| 100 | M&L for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces complete all as specified and directed by Engineer-in-charge. |
| 101 | M&L mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips |
| 102 | M&L Mild steel TMT bars 6 to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips |
| 103 | Dismantling of mild steel work of any description not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge. |
| 104 | S & F Mild Steel work in tubular trusses and tubular posts/ purlins including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to IS :1161-1979 grade st-240 including notching, drilling, fitting, riveting and/or welding or connecting with bed plate, bolt and nuts complete all as specified and directed by Engineer-in-charge. |
| 105 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, incl welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, incl fixing the railing with necessary accessories & stainless steel dash fasterners, stainless steel bolts etc, of required size, on the top of floor or the side of waist stab with suitable arrangement |
| 106 | S&F in repair Corner Glass shelf 300mm complete all as specified and directed by Engineer-in-charge. |
| 107 | S & F in repairs chromium plated hand shower (health faucet) 1 meter, with PVC tube with wall hook , complete all as specified and directed by Engineer-in-charge. |
| 108 | Demolition of precast concrete block walling, built in cement mortar including all quoins, arches, pillars, etc |
| 109 | M & L for Pre-cast PCC block masonry type B-1 (1:2:4) with solid block and set in CM1:6 all as specified and directed by Engineer-in-charge. |
| 110 | Taking down carefully copper point wiring (light, fan, socket or power) DBs, light fittings complete offering credit, making good disturbed surfaces of walls, floors, etc, complete all as specified and directed by Engineer-in-charge. |
| 111 | M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including concealed PVC conduit and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including ISI marked modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) concealed in walls, with modular cover plate for housing the switches, socket outlets,fan regulators etc., complete all as specified and directed by Engineer-in-charge for the following:- Note:-Modular cover plate will be measure seperately |
| 112 | (a) One light point controlled by one switch |
| 113 | (b) One exhaust fan/ wall fan point controlled by one switch |
| 114 | (c)One light point controlled by two 2 way switch |
| 115 | (d) One fan point controlled by one switch and one regulator |
| 116 | (e ) One 3 pin switch socket outlet point 5 amps on same board with other switches |
| 117 | (f) One 3 pin switch socket outlet point 5 amps on independent board |
| 118 | All as per item No 111 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and directed by Engineer-in-charge. |
| 119 | Supply and fixing Modular switch 1 way 6 A, 1 module complete all as specified and directed by Engineer-in-charge. |
| 120 | Supply and fixing Modular switch 1 way 16 A, 1 module complete all as specified and directed by Engineer-in-charge. |
| 121 | Supply and fixing Modular switch 2 way 6 A, 1 module complete all as specified and directed by Engineer-in-charge. |
| 122 | Supply and fixing modular socket outlet, 2/3 pin combined , 6/16 Amps, combined 2 module, 230 volts complete all as specified and directed by Engineer-in-charge. |
| 123 | Supply and fixing modular socket outlet, 2/3 pin combined , 6 Amps, combined 2 module, 230 volts complete all as specified and directed by Engineer-in-charge. |
| 124 | S & F modular white cover plate with frame, 3 module all complete as specified and directed by Engineer-in-charge. |
| 125 | S & F modular white cover plate with frame, 4 module complete all as specified and directed by Engineer-in-charge. |
| 126 | S & F modular white cover plate with frame, 6 module all complete as specified and directed by Engineer-in-charge. |
| 127 | S & F modular white cover plate with frame, 8 module complete all as specified and directed by Engineer-in-charge. |
| 128 | Supply and fixing modular fan step regulator, 230 V, AC, 120W - 2 module |
| 129 | Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and directed by Engineer-in-charge. |
| 130 | Taking down serviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers, safety wire of size not less than 1.00mm & bolts including cotter pin for complete all as specified and directed by Engineer-in-charge. |
| 131 | Taking down serviceable exhaust fan 300 mm sweep/ wall fan 400 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades complete and refixing back at site with new clamps, nuts, washers & bolts complete all as specified and directed by Engineer-in-charge. |
| 132 | Supply and fix sheet metal enclosures Loadline vertical distribution board TPN,4 ways 415 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs and in and including 100A MCCB ,16KA as incomming complete all as specified and directed by Engineer-in-charge and as directed including taking down old MCB DBs complete including cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades,shelves,lintels,etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete all as specified and directed by Engineer-in-charge. |
| 133 | Supply and fix metal enclosure distribution board SPN, 12 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs including taking down old MCB/DB complete all as specified and directed by Engineer-in-charge.Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc |
| 134 | Supply and fix MCB single pole 240 volts, 6 to 32 amps \\"B\\" series complete all as specified and directed by Engineer-in-charge. |
| 135 | Supply and fix single pole and netural 240 Volts 40 amps complete all as specified and directed by Engineer-in-charge. |
| 136 | Supply and fixing aluminium housing LED batten 22 /20 Watt mounted batten fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all complete all as specified and directed by Engineer-in-charge and as diected. |
| 137 | S&F 25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 building secuirity luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed on walls complete all as specified and directed by Engineer-in-charge. |
| 138 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed by Engineer-in-charge plate No. 3 of SSR part - I |
| 139 | M & L for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including concealed PVC conduit and all accessories fixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and directed by Engineer-in-charge. Note : (1) Two runs of cable one run of conduit one run of earth continuity conductor shall be measured as one running metre. |
| 140 | All as per above item No. 133 above but of size 4 sqmm complete all as specified and directed by Engineer-in-charge. |
| 141 | Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 50 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacers including taking down of old unserviceable existing LT UG cable, scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete with aluminium lugs as required at site and complete all as specified and directed by Engineer-in-charge. |
| 142 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/loose Soil |
| 143 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil / hard dense soil. |
| 144 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point. |
| 145 | Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked complete all as specified and directed by Engineer-in-charge. |
| 146 | S&F GD tube light grade 50mm bore with all fittings laid in trenches. |
| 147 | Material and Labour for cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with cement concrete 1:2:4, type, B-2 to match the existing surfaces of the road all complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail