| 1 | Supply laying connecting and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor,1100 volts grade of size 240 sq mm 3.5 core. |
| 2 | Supply, laying connecting & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts (Earthed) grade, of size 95 sq mm 3 core. |
| 3 | Excavation in trenches, in any type of soil not exceeding 1.5m wide or 10 Sqm on plane and not exceeding 1.5m in depth for foundation, Pole, shafts, cesspits, manholes, pier holes, laying of UG cables etc and getting out in any type of soil complete all as specified and directed. |
| 4 | All as per srl item No. 03 above but for each additional 1.5m or part thereof in depth beyond the first 1.5m. |
| 5 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete. |
| 6 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete. |
| 7 | Material and labour for clean and dry sand (unwashed) in trenches and cable ducts including spreading and levelling for cushioning of underground cables all as specified and directed. |
| 8 | Supply and laying well burnt sub class 'B' old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed. |
| 9 | Supply and laying un-reinforced precast concrete cable covers class HV type 1, flat of size 300x180x40 mm complete all as specified. |
| 10 | M & L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 11 | M&L for providing cement concrete type B0 1:2:4 (12.5mm aggregate) coping, kneelers, apex stones, bed plates including necessary form work and forming neat finish surfaces complete all as specified and as directed. |
| 12 | S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 meters long) incl applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of red oxide primer, externally from top of copping complete all as specified and as directed.Note :- Excavation , PCC foundation and copping shall be measured and paid separately. |
| 13 | Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm |
| 14 | Supply, installation, testing and commissioning step down transformer outdoor type plinth mounted , HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz Delta/star, connected vector group DYN -11 copper wound, ONAN, manual type 7 position off circuit tap changing faciality on HT side to vary secondary voltage of +7.5 in steps of 2.5 % continuous rating of capacity not less than 500 KVA incl HV cable box on HT side and busbar duct on LV side for connecting sandwich busbar of capacity 1000 amps. The transformer shall conforming to IS 1180 part 1 : 2014, level 3 with latest amendment and BEE certified complete with all standard fittings ( Buchholz relay (having contacts for alarm & trip),WTI (having contacts for alarm & trip), OTI(having contacts for alarm & trip), Marshalling box ( Having TTB only), MOG (having contacts for alarm & trip)) etc and accessories gauges, first filling of transformer oil etc complete incl suitable platform with PCC/ brick work and finished with cement morter1:4 as per manufacturer recommended length, width, and height . foundation depth should be 750mm from GL , 125 mm thick PCC slab (1:2:4) Type B-1(nominal mix) using 20 mm graded stone aggregate on top of the platform reinforcement should be 10mm dia 150c/c both way 02 nos ISMB 150 incl Cattle fencing (1.5m high) with suitable RCC pillars all around incl gate of suitable size as recommended by Engr in charge).(a) oil conservator with filling holes and cap drain valve and oil level gauge.(b) Silica gel breather with connecting pipe, first fill of dehydrating agent.(c) Exposion relief mounted on tank with double diaphragm and equalizer pipe connected to conservator air spoon( pressure release valve)(d) Air release plug.(e) OTI(having contacts for alarm & trip).(f) Buchholz relay (having contacts for alarm & trip).(g) WTI (having contacts for alarm & trip). Please Enable Macros to View BoQ information |
| 15 | Supply, installation, testing and commissioning step down transformer outdoor type plinth mounted , HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz Delta/star, connected vector group DYN -11 copper wound, ONAN, manual type 7 position off circuit tap changing faciality on HT side to vary secondary voltage of +7.5 in steps of 2.5 % continuous rating of capacity not less than 500 KVA incl HV cable box on HT side and busbar duct on LV side for connecting sandwich busbar of capacity 1000 amps. The transformer shall conforming to IS 1180 part 1 : 2014, level 3 with latest amendment and BEE certified complete with all standard fittings ( Buchholz relay (having contacts for alarm & trip),WTI (having contacts for alarm & trip), OTI(having contacts for alarm & trip), Marshalling box ( Having TTB only), MOG (having contacts for alarm & trip)) etc and accessories gauges, first filling of transformer oil etc complete incl suitable platform with PCC/ brick work and finished with cement morter1:4 as per manufacturer recommended length, width, and height . foundation depth should be 750mm from GL , 125 mm thick PCC slab (1:2:4) Type B-1(nominal mix) using 20 mm graded stone aggregate on top of the platform reinforcement should be 10mm dia 150c/c both way 02 nos ISMB 150 incl Cattle fencing (1.5m high) with suitable RCC pillars all around incl gate of suitable size as recommended by Engr in charge).(a) oil conservator with filling holes and cap drain valve and oil level gauge.(b) Silica gel breather with connecting pipe, first fill of dehydrating agent.(c) Exposion relief mounted on tank with double diaphragm and equalizer pipe connected to conservator air spoon( pressure release valve)(d) Air release plug.(e) OTI(having contacts for alarm & trip).(f) Buchholz relay (having contacts for alarm & trip).(g) WTI (having contacts for alarm & trip). Please Enable Macros to View BoQ information |