| 1 | Supply & Fixing of 63A 4Pole 2Way Center- OFF, CAM Operated Rotary Type Change Over Switch with suitable size MS box enclosure, fixing the same to DG panel i/c inter-connection wiring complete etc as reqd. | Supply & Fixing of 63A 4Pole 2Way Center- OFF, CAM Operated Rotary Type Change Over Switch with suitable size MS box enclosure, fixing the same to DG panel i/c inter-connection wiring complete etc as reqd. |
| 2 | Replacement of faulty contactor coil in the 63A 4Pole power contactor AC3 rated inside DG AMF control panel i/c removing the faulty one and making connection, testing etc as reqd. | Replacement of faulty contactor coil in the 63A 4Pole power contactor AC3 rated inside DG AMF control panel i/c removing the faulty one and making connection, testing etc as reqd. |
| 3 | Supply & Laying of following size PVC inculated copper conductor single core cable with suitable copper lugs, making connections etc as reqd. (i) 4X10 Sqmm | Supply & Laying of following size PVC inculated copper conductor single core cable with suitable copper lugs, making connections etc as reqd. (i) 4X10 Sqmm |
| 4 | Replacement of existing rusted exhaust pipe with a new 40mm/ 50mm Dia 'B' Class MS pipe i/c fabrication work like cutting, welding, joining, Providing Aluminium Painting etc as reqd. | Replacement of existing rusted exhaust pipe with a new 40mm/ 50mm Dia 'B' Class MS pipe i/c fabrication work like cutting, welding, joining, Providing Aluminium Painting etc as reqd. |
| 5 | Supply & Fixing of MS Hinges to the Doors of the DG canopy i/c drilling, fixing, welding, fabrication work complete etc as reqd. | Supply & Fixing of MS Hinges to the Doors of the DG canopy i/c drilling, fixing, welding, fabrication work complete etc as reqd. |
| 6 | Providing Locking arrangement with double 'L' type clamps for 4 Nos hinged doors of the DG canopy i/c welding the clamps to the DG doors to avoid the ran water/ roadent entry inside the canopy by engaging a fabricator for welding, finishing complete etc as reqd. | Providing Locking arrangement with double 'L' type clamps for 4 Nos hinged doors of the DG canopy i/c welding the clamps to the DG doors to avoid the ran water/ roadent entry inside the canopy by engaging a fabricator for welding, finishing complete etc as reqd. |
| 7 | Dismantling of the Locked Fuel Injection Pump (FIP) of 30kVA DG set [As Engine running at extreme over-speed] i/c transporting it to the FIP Service station at Mysore (to & from), replacement of the following spares Parts of the FiP like Plungers & Barrels, Gaskets, Seals, & O-Rings, springs, washers, Control Racks & Pinions etc i/c servicing, calibarion of the FIP for the rated Injection time setting , fixing the same to the DG set, testing on No-load and exchange load complete etc as reqd. | Dismantling of the Locked Fuel Injection Pump (FIP) of 30kVA DG set [As Engine running at extreme over-speed] i/c transporting it to the FIP Service station at Mysore (to & from), replacement of the following spares Parts of the FiP like Plungers & Barrels, Gaskets, Seals, & O-Rings, springs, washers, Control Racks & Pinions etc i/c servicing, calibarion of the FIP for the rated Injection time setting , fixing the same to the DG set, testing on No-load and exchange load complete etc as reqd. |
| 8 | Dismantling of the Damaged Fuel Injection Pump (FIP) of 40kVA, Make: KOEL, Model: 4R1040 DG set i/c transporting it to the FIP service station at Mysore (to & from), replacement of the following Precision spares Parts of the fip , like Delivery Valve, Cam Shaft, Nozzle & Nozzle Holder, Plungers & Barrels, Gaskets, Seals, & O-Rings, springs, washers, Control Rack & Pinion etc i/c servicing, calibarion of the FIP for the rated Injection, fixing the same to the DG set, testing on Noload and exchange load complete etc as reqd. | Dismantling of the Damaged Fuel Injection Pump (FIP) of 40kVA, Make: KOEL, Model: 4R1040 DG set i/c transporting it to the FIP service station at Mysore (to & from), replacement of the following Precision spares Parts of the fip , like Delivery Valve, Cam Shaft, Nozzle & Nozzle Holder, Plungers & Barrels, Gaskets, Seals, & O-Rings, springs, washers, Control Rack & Pinion etc i/c servicing, calibarion of the FIP for the rated Injection, fixing the same to the DG set, testing on Noload and exchange load complete etc as reqd. |
| 9 | Repair of faulty 12 Volts Starter Motor of DG set i/c transportation to work shop to & fro , replacement of Bentex, Rectifier, set of Bearings, Shaft fixing the same to the DG set and testing, checking the output voltage complete etc as reqd. | Repair of faulty 12 Volts Starter Motor of DG set i/c transportation to work shop to & fro , replacement of Bentex, Rectifier, set of Bearings, Shaft fixing the same to the DG set and testing, checking the output voltage complete etc as reqd. |
| 10 | Supply & Fixing of Hydraulic/ metal Braided flexible fuel pipe with Banjo Bolts & Copper washers for supply/ return fuel line etc as reqd. | Supply & Fixing of Hydraulic/ metal Braided flexible fuel pipe with Banjo Bolts & Copper washers for supply/ return fuel line etc as reqd. |