Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work: WELCOME MAINT OF OFFRS ACCN AND PERIODICAL SERVICES TO CERTAIN BUILDINGS, REPIR TO ROOF , ROOF PLASTERS, ROOF TREATMENT, ROOF SHEETING, FALSE CEILING TO CERTAIN BULDING AND DAY TO DAY AND PETTY REPAIRS TO SANITARY FITTING PLUMBING & CARPENTARY WORK AT 4AFSB VARANSI UNDER GE(AF) GORAKHPUR. Contract No.: GE(AF)/GKP/E-14 OF 2026-27 File No. 9452/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of item Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Attending complaint for repair to easing of any type of Doors/Window/Cup Board shutters and chowkhats, aluminum doors by tightening of hinges / handles / aldrop bolt / tower bolt / knobs, hasp and staple etc of any size / any number of panels for easy closing / opening or changing the position of hinges, adjustments of tower bolts, sliding bolts, replacement of looking mirror, curtain rod etc complete including taking down joinery and refixing in the same place and replacement of minimum defective item if required like screws, nails, bits etc, complete all as specified and directed by Engineer in Charge.Notes:- 1. The contractor shall make all arrangement for attending the different types of complaints on every day basis. Any major item required to be replaced with new one, to make the joinery work functional shall be measured and paid for separately as Supply and 'S&F' under respective item of this schedule. Old retrieved item (s) as considered in 'Schedule of Credit' shall become property of the contractor. 1. Rate shall be quoted accordingly against these items, keeping in mind above said provisions.2. The comlaint shall be attended by the contractor within 12 hours, failing which a panel recovery of Rs 200/ complaint shall be recovered from the contractor dues and no dispute will be intertained at later date |
| 3 | S&F in repair Galvanised steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.00 mm including necessary beadings and fillets complete all as specified and directed. |
| 4 | S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or stainless steel wire staples.complete all as specified and directed. |
| 5 | Hacking out old broken glasses any thickness size, quality or description from wooden/metal frames including punching or drilling out old glazing pins / spring clips and providing and fixing new ones. hacking any bldg hight complete all as specified and as directed. |
| 6 | S&F in repair 3mm thick Sheet glass, ordinary quality and glazing with oil putty / wooden beads in square n exc 0.5 sq. m in each pane from wooden or steel frames glazed with putty or fixed with wooden beads complete all as specified and directed. |
| 7 | S&F in repair figured glass 4mm thick pin headed type in square n exc 0.50 Sqm, in square or reqd shape each pane including oil putty complete all as specified and directed. |
| 8 | S&F in repairs 150mm, aluminium anodised, barrel tower bolts of extruded section and fix complete all as specified and directed. |
| 9 | S&F in repair 150 mm Aluminium handles, cast type, anodised etc.complete all as specified and directed. |
| 10 | S&F in repairs 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed |
| 11 | S&F in repairs 75mm Hasp and staple, aluminium anodised, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 12 | S&F in repair butt hinges med weight cold rolled MS, size 100 mm long complete all as specified and directed. |
| 13 | Above above but 75 mm long complete all as specified and directed. |
| 14 | S&F in repair brass 100mm size motrice lock, 4 levers ,vertical type complete all as specified and directed. |
| 15 | S&F in repair aluminium (extruded section) door closer hydraulically regulated designation no 3 universal type suitable for 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. |
| 16 | S&F in repair mild steel helical door spring rat tail rod model including roller plate complete 300 mm long complete all as specified and directed. |
| 17 | S&F in repair stainless steel (SS) curtain rod 25 mm dia and including bracket with fancy type end knobs as per sample complete all as specified and directed |
| 18 | S&F in repairs floor door stopper of aluminium alloy body Overall length of cover plate 140 mm and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 19 | Taking down chowkat or frames exc 1.5 sqm but n exc 4 sqm each with shutters (without taking off shutters from frames) complete all as specified and directed. |
| 20 | Taking down chowkhats with shutters (without taking off shutters from the frames) not exc 1.5 Sqm each complete all as specified and directed. |
| 21 | Taking down shutters of any description not exc 1 Sqm each complete all as specified and directed. |
| 22 | Taking down shutters of any description but exc 1 Sqm and not exc 2 Sqm each complete all as specified as directed. |
| 23 | Taking down shutters of any description but exc 2 Sqm each complete all as specified as directed. |
| 24 | M&L Second class hard wood plain, solid, chowkhats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified as directed. |
| 25 | S&F factory made Pressed steel frames for doors of size 105 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specification all as specified and directed. |
| 26 | S&F factory made Pressed steel frames for doors of size 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specification all as specified and directed. |
| 27 | M&L for PCC 1:3:6 type C1 as in hold fast blocks and filling in pressed steel frame incl. Necessary form work |
| 28 | S&F 35mm thick factory made plain framed, panelled shutter(two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003(part I), kilm seasoned and chemically pressure treated. |
| 29 | S&F for factory made second class hardwood glazed and skeleton door shutters 35mm thick, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc complete all as specified and directed. |
| 30 | S&F facitory made Flush shutters, 30mm thick solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified as directed. |
| 31 | S&F Factory made solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing complete all as specified as directed. |
| 32 | M&L Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS Frame shall be covered with heat moulded plain colour PVC C Channel having a PVC sheet strip of 20mm width stuck inside with solven cement for stiles and plain colour PVC sheets for top rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted ihn th MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solven cement, as per specification & drawing complete all as specified as directed. |
| 33 | M&L for Preparing new wooden surface and applying two coats of synthetic enamel paint over a coat of pink primer of any description exc 10 cm width or girth. |
| 34 | M&L for Preparing new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide of any description exc 10 cm width or girth. |
| 35 | S&F PVC Bathroom Cabinat mirror of selected quality standared size as directed by Engineer-in-charge Make Sea Bird, or equavalent. |
| 36 | S&F in repairs sheet glass shelf assembly consisting of 5.50mm thick glass shelf 12 cm wide with chromum plated bracket guard and railing 60cm long all as specified. |
| 37 | S&F in repair stainless steel steel plate rack of minimum size 970X770X230mm of standard quality, fixed to wall with wooden gutties and screws complete all as specified and directed. |
| 38 | M&L for Resecuring or easing & adjusting without taking down shutters of any description exc 1 sq.m and n.exc 2sq.m each.complete all as specified and directed. |
| 39 | Taking down and refixing in same opening or easing & adjusting shutters of any description exc 1 sq.m &n.exc 2sq.m each complete all as specified and directed. |
| 40 | S&F in repair Anodised Aluminium Snap Grid (size of grid 605x605mm) frame work for false ceiling & Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long complete all as specified.& 8 mm thick non asbestos fibre cement building board fixed or laid/inserted to aluminium framed work complete all as specified and directed.all as specified |
| 41 | Petty repair to leaking bib cock, pillar cock, stop cock, angle valve , gate valve any size, brass spindle, waste pipe, shower rose, float valve,concealed stop cock, PVC connection of any description by changing of jumper washer, spindle for bib cock, pllar cock,concealed stop cock etc or putting M seal cleaning of air lock in the pipe for ensuring proper water supply Repair to leaking flushing cistern low/high level, incl adjustment in the internal fiiting replacement of syphon, washer/jumper, flush handle, lever etc as required , Petty repair for rectification of air lock in GI pipe and making the water supply available upto water taps incl attending the complaints of no water supply.repair to PVC bend, pipe etc . ( Rates are deems to be including replacement washers (hot/cold) ,, flush pipe,GI Nipple,union,Socket,Reducer Socket,bend,Elbow,Reducer Elbow ,Tee,brass spindle, flush syphon, flush handle, pata screws etc) complete all as specified. Notes:-1. The contractor shall make all arrangement for attending the different types of complaints on day to day basis. 1.. Rate shall be quoted accordingly, keeping in mind above said provisions.2. The complaint shall be attended by the contractor within 12 hours from the lodge of complaint, failing which a panel recovery 200/ complaint shall be recovered from the contractors dues. |
| 42 | S&F in repairs 15 mm bore bib tap, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 43 | S&F in repairs \\" flushing cistern kit\\" for complete set to fitted inside as per reqd for cistern functional complete all as specified and directed. |
| 44 | S&F in repairs 15 mm bore bib tap,cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 45 | S&F in repairs 15 mm bore stop valves, cast copper alloy, crewed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 46 | ditto as above but of 20mm bore complete all as specified and directed. |
| 47 | S&F in repairs 15 mm bore angle valves, cast copper alloy fancy type chromium plated, crewed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 48 | S&F in repairs 15 mm bore Pillar taps, cast copper alloy, with capstan heads, fancy type chromium plated, screwed down high pressure, with or without lettered \\"Hot\\" or \\"Cold\\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 49 | S&F in repairs 15 mm bore center hole single lever basin mixer without pop up waste assembly with 10 mm dia 450 mm long braided hoses connection pipe and provision for pop-up Make:- (Jaquar Cat Part No.:- OPP-15051BPM) or equivalent complete all as specified. |
| 50 | S&F in repairs Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed. Complete all as specified and directed. |
| 51 | S&F in repair 32mm waste fittings, brass, chromium plated for wash hand basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed complete all as specified and directed. |
| 52 | ditto above but 40mm dia complete all as specified and directed. |
| 53 | S&F in repair Grating doom 125mm dia of PTMT (minimum wt 40grms) complete all as specified and directed. |
| 54 | S&F in repairs 15mm PTMT Bib tap standard of any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. |
| 55 | S&F in repairs angle valves, 15 mm of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms |
| 56 | S&F in repairs 15mm Ball valves, high pressures of PTMT, withepoxy coated aluminium rod & high-density plastic ball screwed for iron pipe, Minimum wt (15mm -142gms) complete all as specified and directed. |
| 57 | ditto above but size 20mm dia and Minimum wt (for 20mm -210gms) complete all as specified and directed. |
| 58 | S&F in repair white PVC cover for rotational moulded polyethylene water storage tanks 500 ltr capacity, complet all as specified and directed. |
| 59 | S&F in repair white PVC cover for rotational moulded polyethylene water storage tanks 1000 ltr capacity, complet all as specified and directed. |
| 60 | S&F in repair PVC seat cover for EWC of white colour closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.Make-Parriware/Hindware |
| 61 | S&F in repair flush pipe (PVC) for low level flushing cistern including joining to WC complete all as specified and as directed by Engineer in Charge. |
| 62 | S&F in repairs PVC syphon with handle complete for low level flushing cistern complete all as specified and directed by Engr-in-charge. |
| 63 | S&F in repairs PVC polyplast float valve for flush cistern tank complete all as specified and directed by Engr-in-charge. |
| 64 | S&F in repair SS jet spray for water closet with suitable SS flexible pipe of 15 mm bore complete all as specified and directed by Engineer-in-Charge. |
| 65 | S&F 15mm bore steel water tubing medium grade galvanised for fixed to walls, floors, roof ceiling etc including thread, soluvent and taking up or down steel tubing with connectors etc complete all as specified and directed. |
| 66 | S&F 20mm bore steel water tubing medium grade galvanised for fixed to walls, floors, roof ceiling etc including thread, soluvent and taking up or down steel tubing with connectors etc complete all as specified and directed. |
| 67 | S&F in repairs brass CP shower rose with arms 75 mm size fixed to pipe all as in repairs specified and directed. |
| 68 | S&F in repais mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood of size 450mmx600mm and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 69 | S&F in repairs 20 mm dia tubular towel rail brass cromium plated, D type, 60cm long between flanges including one pair of brackets all as specified and directed. |
| 70 | S&F in repair stainless steel kitchen sink with draining board made of stainless steel 1mm thick,coupling plug , washers and waste pipes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915 mm X 460 mm and bowl size 410X330X160 mm complete all as directed . Make- Nirali or equivalent. |
| 71 | S&F in repair Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) |
| 72 | S&F in repair CP bottle trap 32/40mm dia for WHB having minimum water seal 25mm complete all as specified and as directed. |
| 73 | S&F in repairs Two way Angle cock with wall flange of size 15mm bore Make :- (Cera Cat Part No- F2002211) or equivalent complete all as specified |
| 74 | Supply only PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 75 | Ditto above but 600mm long complete all as specified and directed. |
| 76 | S&F in repair PVC waste pipe flexible type suitable for couplings 32mm & 40mm dia 600mm long complete all as specified and as directed by Engineer in Charge. |
| 77 | M&L for replacement of MS brackets for WHB/sink/flushing cistern fixed in repairs incl taking down old brackets and making good damaged surfaces to match with the existing etc complete all as specified and as directed by Engineer in Charge. |
| 78 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 79 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches as in floors, all as specified & directed . |
| 80 | S&F 110mm bore PVC (SWR) bends provided with access door all as specified & directed . |
| 81 | S&F PVC (SWR) Junction single ,(single T) equal or un equal (any radius) 100/110mm complete all specified. |
| 82 | S&F PVC (SWR) P/S trap 125/110 mm,setting and jointing with solvent cement |
| 83 | S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed |
| 84 | S&F 75mm PVC (SWR) bends any radius |
| 85 | S&F PVC (SWR) Junction single ,(single T) equal or un equal (any radius) 75mm complete all specified. |
| 86 | S&F in repairs vitreous China squatting pan, \\"Orrissa\\" pattern, size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. with and including setting the trap and pan in cement concrete bedding1 : 2 : 4, Type B-1, using 20 mm graded crushed stone aggregate minimum 150 mm thick alround and finished just below level of rim of pan to receive the floor finishes including making good floor complete all as specified and directed. |
| 87 | S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) with urinal spreder complete all as specified and directed |
| 88 | S&F in repair 10 ltr capacity PVC valveless,syphonic action type, flushing cistern, low level, white, with inlet ball valve , float and handle including brackets, complete all as specified and directed. |
| 89 | S&F in repair vitreous china wash basin white flat back size 550x400mm excluding taps , waste but including brackets as in repair, complete all as specified and directed. |
| 90 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern, with EWC including p or s trap ,seat cover , including connection to trap /drain and to flushing pipe anti syphonage pipe etc complete including making good floorcomplete all as specified as directed. |
| 91 | S&F in repair Health faucet with 1 meter long easy flexible tube in chrome finish and wall hook with NRV( Back flow preventer) (Jaquar Cat Part No-ALD-CHR-573) or equivalen |
| 92 | S&F in repair SS Soap dish, any type, fixed to plugs with chromium plated brass screws |
| 93 | S&F in repair Stainless Toilet paper Roll holder complete all as spd.(Make- Jaquar Cat No- ACN-CHR-1153S or equivalent. |
| 94 | S&F in repair 500 ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with 20mm bore high desity plastic ball brass valves, high pressure of PTMT with epoxy coated aluminium rod screwed for iron pipe and fixed including dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres all as specified and directed |
| 95 | S&F in repair 1000 ltr capacity rotational mounded polythylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm bore high desity plastic ball brass valves, high pressure of PTMT with epoxy coated aluminium rod screwed for iron pipe and fixed including disconnecting unserviceable PVC/Cement water storage tank of 1000 Ltr capacity complete all as specified and directed. |
| 96 | M&L Petty repair to existing steel window /Rolling Shutters, Pressed steel frame, Rat tails spring, Steel Almirah, Mortise lock fitted in steel Almirah and fixing wire mesh on steel windows by welding in situation and in any floor and including hinges 100 mm medium weight to chowkhats after taking down door/window shutter and refixing in position and making functional,repair /screwing of CGI/Prepainted sheets (Welding rod welding machine, small fittings such as window handle, hinges ,Screws etc will be provided by the contractor) removing the steel window shutters from the frame and re-fixing after making serviceable complete in 4 AFSB Varanasi area complete all as specified and directed by Engineer in Charge.Notes 1. The contractor shall make all arrangement for attending the different types of complaints on day to day basis. Any major item required to be replaced with new one, to make the system functional shall be measured and paid for separately as \\"S&F\\" under respective item of this schedule. 2. Contractor shall provide minimum one welder in a week including all necessary T&P. Additional workers can be engaged if nature of work required to be completed within fix time frame as desired by the GE. Rate shall be quoted accordingly, keeping in mind above said provisions.3. Wherever material is fixed as \\"S&F\\" under respective item of this Sch, the payment for complaint under this item shall not be paid. 4..The comlaint shall be attended by the contractor within 12 hours, failing which a panel recovery of Rs 200/ complaint shall be recovered from the contractor dues and no dispute will be intertained at later date |
| 97 | Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified as directed. |
| 98 | M&L for Rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces,with liquid WPC @ 150 ml per 50 kg of cement or as per manufacturer instructions (WPC will be measured and paid separately), upto double storey finished even and smooth without using extra cement complete all as specified and directed |
| 99 | M&L for rendering 10 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished fair and even smooth without using extra cement complete all as specified and directed |
| 100 | M&L for rendering 5 mm thick cement mortar 1:3 as in ceiling, finished fair and even smooth without using extra cement complete all as specified and directed |
| 101 | Supply only integral liquid water proofing compound complete all as specified and directed. Make :- Dr Fixit Pidiproof LW+ or equivalent in specified make |
| 102 | M&L for preparation of new plastered surfaces and applying two coats of Oil Bound Distemper over a coat of primer 1mm thick wall care putty after complete all as specified and directed |
| 103 | M&L for applying two coat of Oil bound distemper over 1mm wall care putty on ceiling after complete preparation on new plastered surfaces of ceiling. |
| 104 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement based paint,white or tinted (colour & shade as approved by GE) ,complete all as specified and directed. |
| 105 | M&L for preparation new plastered surfaces of any description , including cornices and applying three coats of white wash on Ceiling complete all as specified and as directed. |
| 106 | M&L for complete removal of existing treatment on wall/roof projections for by scrapping with mechanical sander (having mechanical vaccume mechanism) with sanding pad applying one coat of100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489.2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Comany Depot Tinted) with silicon additives @ 1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over a coat of 1mm thick wall care putty . Note:- Primer and emulsion to be carried out through air less spray machine (Mechanical means). Complete all as specified and directed. |
| 107 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises . |
| 108 | M&L for Non - skid coioured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) set complete all as specified and as specified and directed |
| 109 | S&F Glazed ceramic coloured tiles 350x250x7mm /450x350x7mm thick in skirting dados risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10 mm thick cement plaster in cm 1:3 complete all as specified as directed.. |
| 110 | M&L Light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick cement mortar 1:4 bedding complete all as specified and directed |
| 111 | M&L Light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, as skirting etc. set and pointed in white or coloured cement to match over 10mm thick cement plaster in CM 1:3 complete all as specified and directed |
| 112 | Repair/easing/ readjusting of aluminium door/window shutters by taking down shutters from frame and dismentling members of shutters like, glass, rails and styles by necessary cutting, grinding of members etc and refixing of same including rubber gasket ,hinges , handle, screws etc complete all as specified and directed. |
| 113 | M&L anodised aluminium doors with frame size 101.6X44.45X 2 mm thick and shutter aluminium anodised and top rail 47.62 x 44.45 x 1.5 and style 47.50X 44.50 X 1.50 mm,lock rail 83.5X 44.45 X 1.50 mm and bottom rail150.00X 44.50 X 2.50 mm incl necessary aluminium jointing cleats,glazing cleats,rubber packing anodised aluminium shape beading, screws etc with panelling in two parts with 4 mm thick aluminum composite board in lower panel and 5mm thick tinted/plain glass in panels incl all fittings, MS 4 lever mortice lock, floor door spring and all fittings& fixture complete all as spesified and directed |
| 114 | M&L anodised sliding type window with frame size 60X40X2.00 mm thick and shutter with section bearing bottom 52x18X1.50, top 39.4 x17.7 x1.5mm and sides 39.4 x 17.7 x 1.5mm (suitable for moving over two track over top of frame work, top and side section of size 61.6x31.75x1.5mm and bearing bottom track of size 61.6x31.75x1.5mm incl necessary aluminium jointing cleats,glazing cleats,rubber packing anodised aluminium snape beading, screws etc with 5mm thick tinted/plain glass in panels incl all fitting & fixture complete all as spesified and directed. |
| 115 | M&L anodised aluminium grill Wt nexc 3.50 kg per sqm with all fittings& fixture, shape and size as approved complete all as spesified and directed . |
| 116 | S&F in repair 5.5mm thick, sheet/ tinted glass, ordinary quality to be fixed with aluminium beading and rubber gas kit in aluminium frame work as in door/ window/ partition etc all as specified and directed. |
| 117 | S& F in repair aluminum glazing clips / beading for aluminum door and window |
| 118 | S& F in repair rubber gasket for packing / beading for aluminum door and window |
| 119 | S&F in repairs rubber door seal (Rubber Strips) of size 900mmx 50mmx 2 to 3 mm thick fixed to wooden doors complete all as specified and directed by Engineer-in-Charge. |
| 120 | S&F in repair stainless steel kitchen sink without draining board made of stainless steel 1mm thick,coupling plug, washers and waste pipes including bedding in cement mortar on to dwarf wall or including fixing cantelever brackets and connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X160 mm all as specified and directed. Make- Nirali or equivalent. |
| 121 | S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed |
| 122 | S&F 18 mm thick HDMR (High density high moisture resistance) board of grade 1 quality make: Green ply, Action Tesa or other make as approved by GE of one side prelem and other side to suitable for high gloss finish mica of approved quality make :- Century or as approved by GE Fixed with screws, solvent cement/adhesive to make cupboard shutters, sides, top and bottom, shelves inside the cabinet shutter or drawer complete all as specified and directed. |
| 123 | S&F 75 mm size L/Z type stainless hinges fixed screws openable at 110 degree for cabinet shutter Make:- KAFF complete all as specified and directed. |
| 124 | S&F stainless steel handles of 150 mm size for kitchen cabinet shutter/drawer. Complete all as aspecified and directed. |
| 125 | S&F CP SS teliscopic channel 20\\" long, zink (35Kg) make- Sleek (Asian paint) code-HICH- 1356) or equivlents. complete all as specified. |
| 126 | Tank cleaning and removing all scale and directed etc from tanks and from months of circulating pipes etc, exc 250 and n exc 500 ltr capacity (date of cleaning to be mentioned on PVC tank) complete all as specified and directed. |
| 127 | Tank cleaning and removing all scale and directed etc from tanks and from months of circulating pipes etc, exc 500 and n exc1000 ltr capacity (date of cleaning to be mentioned on PVC tank) complete all as specified and directed. |
| 128 | Dismantling Asbestus cement (corrugated semi corrugated,etc sheets in roof coverings, Complete all as specified and directed. |
| 129 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated, steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 130 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Complete all as specified and directed. |
| 131 | M & L for Roughning and cleaning to existing RCC roof surface/Roof treatiment and removing rubbish off the premises, cleaning surfaces of entire roof area, removing all dust ,loose particle and grease with a wire brush or scrubber and preparing to receive new roof treatment. Supply and Application of 5 Layer SHR Waterproofing Coating System as per manufacturer application procedure on leaking concrete roof surface by thorough surface preparation with high pressure water jet min. 125 bars, opening the cracks, followed by one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and min. 50% solids, filling and sealing the cracks, then over coating with 2 Coats of NEEWP + Cement mixture as waterproofing coat having +450% Elongation. The surface is then to be tested for water tightness with a ponding test for min. 2 days and then top-coated with 2 Coats of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 Coats, DFT 100 - 120 microns using brush, roller, airless spray gun as applicable. The product should be certified by NABL Approved Lab and application is to be done by company approved applicator only.The guarantee for treatment shall be given by the contracyor in writing for a period of 5 year and security deposit @ 2.5 % of total cost of treatment shall be given for 5 year from the date of completion of work. |
| 132 | Dismantling wrought iron or mild steel work of any description not otherwise provided for . Complete all as specified and directed. |
| 133 | S&F steel work in tubular Post/ trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St-240 including all necessary work as directed by Engr in Charge. Complete all as specified and directed. |
| 134 | M&L for preparation old decorated surfaces of any description, including cornices and applying one coat of white wash on walls complete all as specified and as directed. |
| 135 | All as per item No. 1 here in above but on ceiling surfaces complete all as specified and as directed. |
| 136 | M&L for preparing of old decorated surfaces and applying one coat of cement based paint on walls complete all as specified and as directed. |
| 137 | M&L washing, rubbing down and stopping of distempered and painted surfaces of walls including cornices etc and applying one coat of oil bound distemper white or tinted with roller. Complete all as specified and as directed. |
| 138 | M&L for preparing of old decorated surfaces and applying one coat of oil bound distemper on ceiling surface,Complete all as specified and as directed. |
| 139 | M&L for preparing of old decorated surfaces and applying two coats of oil bound distemper on walls over 1mm thick wall care putty. complete all as specified and as directed. |
| 140 | M&L for preparation of old painted wooden based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 141 | M&L for preparation of old painted steel surfaces of any description, over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and as directed . |
| 142 | Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 143 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling and paneling on this PVC conduit/casing caping on surface will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes for mounting modular switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed by Engineer in Charge. Note :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. |
| 144 | Ditto as above One 5 Amps socket point controlled by one 5 Amps switch on same board. |
| 145 | Ditto as above One 5 Amps socket point controlled by one 5 Amps switch on independent board. |
| 146 | Ditto as above One bell point controlled by one 5 Amps bell push. |
| 147 | Ditto as above One light point controlled by two 5 Amps two way switch. |
| 148 | Description all as per item above here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 149 | M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit/casing caping on surface and 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes for mounting switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed by Engineer in Charge. |
| 150 | Ditto as above but for one 5 Amps socket point controlled by one 5 Amps switch on same board….ditto… |
| 151 | Ditto as above one 5 Amps socket point controlled by one 5 Amps switch on independent board….ditto…. |
| 152 | Ditto as above one bell point controlled by one 5 Amps bell push…ditto….. |
| 153 | Ditto as above One light point controlled by two 5 Amps two way switch. |
| 154 | Description all as per item above here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 155 | S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed. |
| 156 | S&F switch piano, flush type 5/6 amp, single pole, two way 240 volt complete all as specified and directed. |
| 157 | S&F socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed. |
| 158 | S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed. |
| 159 | S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed. |
| 160 | S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed. |
| 161 | S&F modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed. |
| 162 | S&F modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed. |
| 163 | S&F modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed. |
| 164 | S&F modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed. |
| 165 | Supply and fixing switch socket combination multipurpose 5 pin 5/15 Amps |
| 166 | S&F modular bell push pole 1 way, 1 module, 6 Amp complete all as specified and directed. |
| 167 | S&F modular switch single pole 2 way, 1 module, 6 Amp complete all as specified and directed. |
| 168 | S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed. |
| 169 | S&F fan regulator modular electronic step up type, SP 230 volt complete all as specified and as directed. |
| 170 | S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed. |
| 171 | S&F Call bell ding dong, AC single pole 240 volts complete all as specified and directed. |
| 172 | S&F in repair 10 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. |
| 173 | Supply and fixing in repair LED lights fitting 1x20 Watt , 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all accessories internally pre wired fixed to wall/ceiling incl fittings accessories all as specified. |
| 174 | S&F in repair 20 watt rechargeable LED light fitting engineering extruded aluminium batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. |
| 175 | Supply and fixing in repair round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. . |
| 176 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and as directed. |
| 177 | S&F lamp LED 9/12 watt, 240 volts complete all as specified and directed. Make : Make- Havells/Bajaj/Philips/Crompton. |
| 178 | Taking down carefully old and unserviceable sub main wiring of 3/5 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed. |
| 179 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cable,one run of 2.5 sqmm cable and one run of PVC conduit will be measured as one unit |
| 180 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4.0 sqmm cable and one run of PVC conduit will be measured as one unit |
| 181 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- four runs of 4.0 sqmm cable,one run of 4.0 sqmm cable and one run of PVC conduit will be measured as one unit |
| 182 | S&F modular type PVC enclosure with a two pin and earth plug and socket 16 Amps complete with one single pole MCB 20/25 Amps capacity complete all as specified and directed. Make: Havells/HPL/ANCHOR |
| 183 | S&F in repair factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed. |
| 184 | S&F in repair factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed. |
| 185 | S&F in repair factory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed. |
| 186 | S&F in repair for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 187 | S&F in repair MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 188 | S&F in repair MCB, SP, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 189 | S&F in repair MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 190 | S&F in repair MCB, TPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 191 | Supply only tape insulation, 1100 volts grade 20mm width, 15 mtrs long complete all as specified and directed. |
| 192 | S&F in repair flexible wire 23/0.0076, twin core twisted, PVC insulated copper stranded conductor complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail