Tender For Restoration, Repair, Refrigerant Charging, Controller Programming, And Re-Commissioning Of 135 Tr Screw Chiller Unit (Model: Acegwfxr1351mln272) At Punjab & Haryana Assembly, Sector-1, Chandigarh. (Ch To : Recoverable Head 8658 Pb. & Hry.)
Name of Work:- Restoration, Repair, Refrigerant Charging, Controller Programming, and Re-commissioning of 135 TR Screw Chiller Unit (model: ACEGWFXR1351MLN272) at Punjab & Haryana Assembly, Sector-1, Chandigarh. (Ch to : Recoverable Head 8658 Pb. & Hry.).
Sl. No.
Item Description
1
\\"Supply, Charging and commissioning of Refrigerant R-134a gas in 135 TR Screw chiller, including leak testing, evacuation, Complete system vacuuming, refrigerant charging as per OEM specifications, and ensuring proper functioning of chiller unit.\\" .NSR
2
\\"Testing and rectification of NRV (Non -Return Valve) of screw chiller, including identification and repair of refrigerant leakage, system flushing using dry nitrogen, pressure testing, evacuation and vacuuming of the system, followed by re-commissioning and starting of the chiller unit as per standard engineering practices, ensuring leak-free and efficient operation.\\" .NSR
3
\\"Programming of chiller controller and configuration of all operating parameters as per original OEM settings, including system calibration, testing, and commissioning, to be executed by authorized engineering, ensuring effcient and satisfactory operation of the chiller unit.\\" .NSR
4
\\"Re-commissioning of screw chiller unit, including refrigerant charging, checking of all components, and carrying out necessary ancillary works, ensuring proper functioning and satisfactory operation of the system.\\" .NSR
5
\\"Pressure testing of chiller circuit with dry nitrogen after completion of leak repair, including nitrogen holding for up to 24 hours, followed by evacuation and vacuuming of the system, ensuring leak-free and satisfactory operation.\\" .NSR
6
\\"Suppling, installation, testing and commisioning (SITC) of compressor lube oil as per OEM recommendations, including filling, checking of oil level, and ensuring proper lubrication and satisfactory operation of the chiller unit.\\" .NSR Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.