| 1 | Clearing and grubbing land including uprooting rank vegetation, grass,bushes, shrubs, saplings and tree girth upto 300 mm, removal of stumpsoftrees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned upto a lead of 1000 meters including removal and disposal of top organic Soil notexceeding 150mm in thickness as per clause 201 of MORT&H Spesifications for Road & Bridge works (4th Revision)Ground Floor |
| 2 | Earth work in foundation in hard soil or gravelly soil within 50m intial lead and lifts 1.5 M intial lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site including cost of all labour, T&P and dewatering if required for the work etc. complete as per drawing and Technical specification and as directed by the Engineer-in-Charge.Ground Floor |
| 3 | Earth work in filling in foundation and plinth with excavated materials / Earth within initial lead of 50.00mtr. & initial lift of 1.5 mtr. including cost of all labour T&P, watering and ramming as directed by the Engineer-in-Charge Ground Floor |
| 4 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge.Ground Floor |
| 5 | Providing and laying (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and sand of approved quality and from approved quarry including laying concrete in layers not exceeding 15cm in depth, ramming, watering and curing etc. complete to required levels including cost, conveyance, royalties, taxes of all materials and cost of all labours, T&P etc complete as per the direction of the Engineer in charge.Ground Floor |
| 6 | Providing and laying PCC / RCC (1:2:4) in all floors using 12mm size crushed stone granite aggregates including laying in layers, ramming, watering and curing etc. complete including cost, conveyance, royalties, taxes of all materials and cost of all labours, T&P etc complete as per the direction of the Engineer in charge.Ground Floor |
| 7 | R.C.C. work of M.20 in Foundation using 20 mm & down graded size crushed stone granite aggregates including hoisting lowering, laying concrete and compacting by using vibrators, watering, curing and necessary centring & shuttering for smoth finishing of work excluding steel reinforcement work including cost, conveyance, royalties, taxes of all materials and cost of all labours, T&P etc complete as per the direction of the Engineer in charge.Ground FloorColumn Base |
| 8 | Ground FloorPlinth Beam |
| 9 | Ground FloorRoof Beam |
| 10 | Ground FloorColumn |
| 11 | First FloorColumn |
| 12 | Head RoomColumn |
| 13 | Ground FloorLintel |
| 14 | First FloorLintel |
| 15 | Head RoomLintel |
| 16 | Ground FloorChajja over opening |
| 17 | First FloorChajja over opening |
| 18 | First FloorRoof Beam |
| 19 | Head RoomRoof Beam |
| 20 | Ground FloorStair Case |
| 21 | First FloorStair Case |
| 22 | Ground FloorRoof Slab |
| 23 | First FloorRoof Slab |
| 24 | Head RoomRoof Slab |
| 25 | Supplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-415/ 500 / 550) steel of approved manufacturer as per section 1600 §ion 1900 of MORT&H specification for Road and Bridge works ( 4th revision) including cost, conveyance and taxes of all materials, binding wires 18 to 20 gauge and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. (weight of reinforcement sall be calculated on the basis of IS 1732. wastage, overlaps, couplings, welded joints, space bars, chairs, stays, hangers and annealed steel wires or other method of binding & placing shall not be considered for payment)Ground Floor |
| 26 | First Floor |
| 27 | Head Room |
| 28 | Fly ash brick masonry in all floors with cement mortar (1:6) using bricks of 23cm size, after immersing Bricks before use with watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge.Ground Floor |
| 29 | First Floor |
| 30 | Head Room |
| 31 | 16 mm thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.Ground Floor |
| 32 | First Floor |
| 33 | Head Room |
| 34 | 12 mm (1/2\\") thick Cement Plaster (1:6) finished smooth to masonry brick walls in complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-charge.Ground Floor |
| 35 | First Floor |
| 36 | Head Room |
| 37 | 6mm thick cement plaster (1:4) over RCC works including deep chipping, finished smooth with proper thickness, watering, curing for required days with cost, conveyance, royality, taxes of all materials and labour with T&P required or the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-charge.Ground Floor |
| 38 | First Floor |
| 39 | Head Room |
| 40 | Supplying and fitting-fixing of Un plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD.) Casement Door 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 102 mm x 60 mm x 2.25 mm for casement Door Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding the door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638 14,EN 477 95 and other applicable codes and standards. (D and D4) etc complete as per direction of Engineer in Charge. (including Door Frame)Ground Floor |
| 41 | First Floor |
| 42 | Supplying and fitting-fixing of Un plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD.) Casement Window with top fixed 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges,materials and product conforming to ASTM D 638 14,EN 477 95 and other applicable codes and standards. (W) etc complete as per direction of Engineer in Charge.(including Window Frame)Ground Floor |
| 43 | First Floor |
| 44 | Supplying and fitting-fixing of Un plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD.) Ventilator/ Top Hung 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638 14,EN 477 95 and other applicable codes and standards. (V) etc complete as per direction of Engineer in Charge.Ground Floor |
| 45 | First Floor |
| 46 | Supplying of M.S. Grills etc including cost,conveyance of all materials etc.complete as per the instruction of Engineer-in-Charge .Ground Floor |
| 47 | First Floor |
| 48 | Head Room |
| 49 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge.Ground Floor |
| 50 | First Floor |
| 51 | Head Room |
| 52 | Painting two coats with plastic emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.Ground Floor |
| 53 | First Floor |
| 54 | Head Room |
| 55 | Painting two coats with approved weather seal paints of approved colour, shade on wall surface over a coat of wall primer including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge.Ground Floor |
| 56 | First Floor |
| 57 | Head Room |
| 58 | Painting two coat with any approved senthetic enamel paint over a coat of primer over the iron surface including with all cost etc, complete.Ground Floor |
| 59 | First Floor |
| 60 | Head Room |
| 61 | Supplying, fitting & fixing of Supplying, fitting and fixing Vertified Tile 600mm x 600mm plain (Ivory) of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-chargeGround Floor |
| 62 | First Floor |
| 63 | Supplying, fitting, fixing of Vitrified tiles (60cm x 60cm: colour) in dadoo in all floors over 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.Ground Floor |
| 64 | First Floor |
| 65 | Supplying, fitting and fixing chequered tile of approved make conforming to is:13755 laid on 20mm thick cement mortar (1:4) (1 cement :4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-In- ChargeGround Floor |
| 66 | Supplying, fitting, fixing of Granite tiles of size 0.1 to 0.4sqm (Pulished) in floors over 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.Ground Floor |
| 67 | First Floor |
| 68 | Supplying, fitting and fixing hand railing of Stainless steel of 304 grade using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. required for the complete in all respect as per direction of the Engineer-in-charge.Ground Floor |
| 69 | First Floor Please Enable Macros to View BoQ information |