| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. asrequired.. |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 3 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 4 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 5 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the samein case of recessed conduit as required. |
| 7 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No.4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 9 | 3 pin 5/6 A socket outlet |
| 10 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 11 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as |
| 12 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches inrecess etc. As required. 1 or 2 module(75mm X 75 mm ) |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. |
| 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, |
| 15 | Supplying and fixing 3 pin 5A ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 16 | Supplying and fixing brass batten/angle holder including connection etc as required. |
| 17 | Installation testing & commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc.as required |
| 18 | Installation testing & commissioning of ceiling fan, including wiring the down rod of standard length (upto 30 cm) with 1.5 sq.mm FRLSH PVC insulated, copper conductor single core cable etc.including providing and fixing phenolic laminated sheet cover on the fan box etc.as required. |
| 19 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. upto 450 mm sweep. |
| 20 | Extra for fixing the louvers/shutters complete with frame for exhaust fans of all sizes. |
| 21 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (for A.C.Point/MCB Point) |
| 22 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia,M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 23 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc complete asrequired. |
| 24 | 12 way, Double door |
| 25 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andSingle Pole |
| 26 | Double Pole |
| 27 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. asrequired. |
| 28 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc. with. |
| 29 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 30 | Providing and laying of 6 SWG G.I. Wire at0.50 meter below ground level for conductor earth electrode, including connection/terminating with G.I. thimble etc. as required. |
| 31 | Laying of one number PVC insulated and PVC sheated/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation sand cushioning,protective covering and refilling the trench etc.asrequired. Upto 35 sq. mm |
| 32 | Supply & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheated/XLPE aluminium conductor cable of 1.1 KV grade asrequired. 2 X 10 sqmm. (19mm) |
| 33 | Providing, laying and fixing following diaG.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cmdeep)and re-filling etc as required. 100 mm Dia |
| 34 | Supply and following size of 1.1 KV grade multicore aluminium conductor PVC sheated armoured cable as per IS 1554 ( 10 sqmm 2core) 10 sqmm 2 core |
| 35 | Supply and erection of 1 X 10 W mirror lightcomplete in all respect. |
| 36 | Supply & fixing of 7/9 Watt LED Bulb.Complete in all respect. |
| 37 | Supply and fixing of LED Tube Light with batten suitable for up to 1X40 Watt LED Tube Light complete including tube etc.on surfacecomplete in all respect. |
| 38 | Supply & fixing of recess mounting round15 to 18 watt LED concealed light having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. -AAA |
| 39 | Supply & fixing of 230/250 volts, 50 Hz 55 W 1400 rpm exhaust fan including providing nuts,bolts,mounting frame and other accessories including connection etc.complete as required-Make : Havells-Standard -RefreshAir -SPS ( 300 mm sweep) 300mm sweep. |
| 40 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making goodthe walls and floors wherever required : W.C. pan with ISI marked white plastic seat and lid |
| 41 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and makinggood the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm withsingle 15 mm C.P. brass pillar tap |
| 42 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and makinggood the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 200 mm |
| 43 | Semi rigid pipe |
| 44 | Providing and fixing P.V.C. waste pipe for sink or wash basinincluding P.V.C. waste fittings complete. a) 32mm dia |
| 45 | b) 40mm dia |
| 46 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washerscomplete. |
| 47 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean typeW.C. of quality and make as approved by Engineer-in-charge. 15mm nominal bore |
| 48 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 49 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 50 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality andcolour, weighing not less than 88 gms. |
| 51 | Providing and fixing toilet paper holder : C.P. brass |
| 52 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work -Exposed on wall 25mm dia nominal bore |
| 53 | Painting G.I. pipes and fittings with two coats of anti-corrosivebitumastic paint of approved quality : 25mm dia nominal bore. |
| 54 | internal work -Exposed on wall |
| 55 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing ofjoints complete as per direction of Engineer in Charge. 20mm dia nominal outer dia pipes |
| 56 | 25mm dia nominal outer dia pipes |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes |
| 58 | 20mm dia nominal outer dia pipes |
| 59 | 25mm dia nominal outer dia pipes |
| 60 | Providing and fixing uplasticised PVC connection pipe with brassunions : 45 cm length 15mm nominal bore |
| 61 | Providing and fixing C.P. brass bib cock of approved qualityconforming to IS:8931 : 15mm nominal bore |
| 62 | Providing and fixing C.P. brass angle valve for basin mixer andgeyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 63 | Providing and fixing gun metal gate valve with C.I. wheel ofapproved quality (screwed end) : 25mm dia nominal bore |
| 64 | 20 mm dia nominal bore |
| 65 | Providing and fixing ball valve (brass) of approved quality, Highor low pressure, with plastic floats complete :25 mm nominal bore |
| 66 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support fortank. |
| 67 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil asdirected, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mmdia |
| 68 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1cement : 1 fine sand) including testing of joints etc. complete : V100mm diameter |
| 69 | 150mm diameter |
| 70 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-roundS.W. pipes including bed concrete as per standard design : 100mm diameter P.V.C. Pipe |
| 71 | 150mm diameter P.V.C. Pipe |
| 72 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tightC.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design:With Sewer bricks conforming to IS : 4885 |
| 73 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 74 | 1.50mt to 3.0 mt |
| 75 | 3.0 mt to 4.50 mt |
| 76 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size |
| 77 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing andreinforcement, with 1:1.5:3(1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 78 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 79 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 80 | Steel reinforcement forR.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe- 500 D or more. |
| 81 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with20 mm nominal size stone aggregate |
| 82 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mmcement plaster |
| 83 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
| 84 | Providing and fixing C.I. tee at the inlet and outlet ofseptic tank. |
| 85 | Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socketed pipe as per IS: 3989 |
| 86 | Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989 |
| 87 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape andapproved quality M D - 10 |
| 88 | L.D . -2.5- Circular shape450mm internal |
| 89 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 90 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 91 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate40 mm nominal size |
| 92 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 93 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 94 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 95 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 96 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement :4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size |
| 97 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 98 | Brick work with common burnt clayF.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 99 | Brick work with common burnt clayF.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 100 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 101 | 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) |
| 102 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 103 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 104 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade withordinary paint of approved brand and manufacture |
| 105 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 300 mm dia |
| 106 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia |
| 107 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 108 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 109 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.. |
| 110 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 100 mm dia |
| 111 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 150 mm dia |
| 112 | Providing and fixing G.I. pipes completewith G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore |
| 113 | Supply and fixing of Armoured cable ISImarked (4 sqmm 3 core) |
| 114 | Pumping Set KSB make submersible pump set suitable for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications. (1.5H.P.) |
| 115 | Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality. |
| 116 | Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well.. |
| 117 | Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories. |
| 118 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 119 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil. |
| 120 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 121 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40mm nominal size) |
| 122 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.4 0 mm thick with 20 mm nominal size stone aggregate |
| 123 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating anddressing complete. |
| 124 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 125 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size) |
| 126 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 127 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 128 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 129 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 130 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6coarse sand) |
| 131 | Half brick masonary with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) |
| 132 | Foundations, footings, bases of columns, etc. for massconcrete |
| 133 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 134 | Suspended floors, roofs, landings, balconies and accessplatform |
| 135 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 136 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more |
| 137 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 138 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarsesand) |
| 139 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 140 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 141 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 142 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double Charged Vitrified tiles Polished finish of Size 600 x 600 mm. |
| 143 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mmthick |
| 144 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Granite stone slab of colour, Black, Cherry/Ruby red, Area of slab over 0.50 sqm) |
| 145 | Supply and fixing of Polyester Powder Coated aluminium windows having 2 mm thick aluminium section including coating & an average coating of 50 micron fully glazed made of aluminium door tube size83.5 X 44.65 mm as vertical member & 1114.00 X 44.45 mm size tube in bottom and horizontal members door chaukhat should be of aluminium tubular vertical with two openable shutters.The rate will include cost of material fixtures, 5 mm glass handles, locks, screw necessary beeding & excluding cost of floor spring if required for proper completion of work as per direction of Engineer Incharge. |
| 146 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 147 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete.250mm x 16mm . |
| 148 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. 250mm x10mm . |
| 149 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge. 150mm x 10mm.(Polyester Powder coated minimum thickness 50 micronaluminium) |
| 150 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge. 150mm x 10mm.(Polyester Powder coated minimum thickness 50 micronaluminium) |
| 151 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.(Twin rubber stopper) |
| 152 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. |
| 153 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 154 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @2.20 kg/10 sqm) |
| 155 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: With average thickness of 120 mm and minimum thickness at khurraas 65 mm. |
| 156 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 157 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cementmortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 158 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 159 | Bend 87.5° |
| 160 | Shoe (Plain) |
| 161 | Providing and fixing to the inlet mouth of rain waterpipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 162 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 163 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment |
| 164 | PROVIDING AND FIXING OF INAUGURATION STONE |
| 165 | INTERLOCKING TILES WITH KERB STONE |
| 166 | LESS 5% DUE TO COMPETITIVE PRICE EFFICIENCY |
| 167 | ADD 1% FOR LABOUR CESS ON (A) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail