| 1 | Demolition of Brick work or stone/boulder masonry, PCC solid blocks laid built in cement mortar complete all as specified and as directd. |
| 2 | Demolition of reinfroced cement concrete of any description and in any position not otherwise specifically provided for beam, staircase, landing, chajjas and similar suspended work complete all as specified and as directed. |
| 3 | Material and labour for precast cement concrete solid block type B1 1:2:4 (using 20mm graded stone aggregate) exc 10cm in width and setting in cement mortar 1:4 complete all as specified and as directed. |
| 4 | Material and labour for 10mm thick cement mortar plaster on brick wall in concrete surface in CM 1:4 finished even and smooth without using extra cement, complete all as specified and as directed. |
| 5 | Material and labour for preparation of new plastered surfaces of walls and applying two coat of antifungal weather proof paint of required shade over a coat of primer using modern tools, and spray technique complete all as specified and as directed |
| 6 | Material and labour for complete removal of existing treatment by mechanical jet spray /grinder or walls and applying two coats of distemper oil emulsion over a coat of primer through authorized company applicator using modern tools, and spray technique complete all as specified and as directed. |
| 7 | Supply and fixing Powder coated aluminum frame for Door, windows, ventilator/other work with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed |
| 8 | Supply and fixing powder coated( minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges(150mm size-3 nos), anodised aluminium snap beading, screws etc. complete all as specified and as directed |
| 9 | Supply and fixing powder coated (minimum thickness of powder coating 50 micron) aluminum door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges (150mm size-3 nos), anodised aluminium snap beading, screws etc. complete all as specified and as directed |
| 10 | Material and labour for veneered decorative plywood 9mm thick, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame all as specified and as directed. |
| 11 | Supply and fixing anodized aluminium snap grid frame work for false ceiling all as specified size of grid 605 x 605 mm including hanging with mild steel 2mm dia wire in suitable length complete all as specified and as directed |
| 12 | Providing and fixing Gypsum board 600mmX600mmX12mm thick in ceiling with screw as per manufacturer’s instructions complete as specified and as directed. |
| 13 | Demolition of unreinforced cement concrete in ground floors and paving n.exc. 15cm thickness (below or above ground level) complete as specified and as directed. |
| 14 | Material and labour for 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregates) as in flooring including finishing cement concrete rough surface without using extra cement, complete all as specified and as directed |
| 15 | Material and labour for Machine cut kota stone slab flooring 20-25mm thick, screed bed or bedding layer of 20mm thick cement mortar 1:6 laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc. Complete all as specified and all as directed. |
| 16 | Material and labour for Machine cut kota stone slab in riser of steps, skirting, dado and pillar laid over cement screed and jointed, backing coat layer of 20mm thick cement mortar 1:6 laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc. Complete all as specified and as directed. |
| 17 | Supply and fix in repair Steel rolling shutters push pull or manual type having thickness of lath 1.25mm, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete all as specified and as directed. |
| 18 | Supply and fix in repair Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 19 | Supply and fix in repair Steel rolling shutters gear operated type with bevel gear box and crank handle having thickness of lath 1.25mm, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete all as specified and as directed. |
| 20 | Material and labour for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed. |
| 21 | Supply and fixing for MS Framed work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. and fixing complete Fe 410-W(Gde-E-250) Quality 'A' all as specified and as directed. |
| 22 | Supply and fixing for MS Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W(Gde-E-250) Quality 'A' all as specified and as directed. |
| 23 | Supply and fixing Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe-410-W(Gde- E-250) quality-B for cover of cable duct and all other complete all as specified and as directed |
| 24 | Supply and fix Mild steel screw bolts dia of neck 5 to 10 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, bolt length of bolt exc 5cm but n exc 10cm long complete all as specified and as directed. |
| 25 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self-tapping screws complete all as specified and as directed. |
| 26 | Material and labour for TMT bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 27 | Material and labour for reinforced cement concrete type B1 1:2:4 (nominal mix) using 20mm graded stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs and mass concrete etc complete all as specified and as directed. |
| 28 | Material and labour for use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of and similar work; vertical or to batter vertical or to batter complete all as per specified and as directed. |
| 29 | Material and labour for cement concrete type B2 1:2:4 (40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as per specified and as directed. |
| 30 | Supply, installation, testing and commissioning of Fire Alarm control panel complying with BS EN 54 single Loop panel of capacity from 99 detectors & 99 Modules & up to 200 detectors and modules (per each loop) complete all as specified and as directed |
| 31 | Supply, installation, testing and commissioning of Short circuit isolators complete all as specified and as directed |
| 32 | Supply, installation, testing and commissioning of detectors complying with and type certified to EN - 45 Addressable type muiltisensor detectors with heat and smoke with combination complete all as specified and as directed. |
| 33 | Supply, installation, testing and commissioning of Addressable Manual Call Point re-settable type complete all as specified and as directed |
| 34 | Supply, installation ,testing and commissioning of Addressable electronic Sounder cum Strobe complete all as specified and as directed. |
| 35 | Supply and fix Remote response indicators all as specified and directed. |
| 36 | Supply, installation, testing and commissioning of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade complete all as specified and as directed. |
| 37 | Supply ,installation, testing and commissioning of Automatic Modular Type ABC powder Fire Extinguisher with activation temperature of 68 degree, 5 kg roof mounting type with 3.5 to 4 sqm with working pressure 15 bar including installation at GI pipe/sheet with connect accessories complete all as specified and as directed |
| 38 | Supply and laying or passing through duct/ GI pipe or fixing on wall LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty with aluminium conductor of size 3.5 core 70 sq mm with suitable size thimbles, glands complete all as specified and as directed . |
| 39 | Supply and laying or passing through duct/ GI pipe or fixing on wall LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty with aluminium conductor of size 3.5 core 50 sq mm with suitable size thimbles, glands complete all as specified and as directed . |
| 40 | Supply and laying or passing through duct/ GI pipe or fixing on wall LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty with aluminium conductor of size 3.5 core 35 sq mm with suitable size thimbles, glands complete all as specified and as directed . |
| 41 | Excavation in trenches, in any type of soil not exceeding 1.5m wide or 10 sqm on plane and not exceeding 1.5 m in depth for foundation, pole, shafts, cesspits, manholes, pier holes, laying of UG cables etc. and getting out in any type of soil complete all as specified and as directed. |
| 42 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed |
| 43 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 44 | Supply and laying of DWC (Double wall corrugated) pipes of size 63 mm outer dia,IS:16205(Part-24) laid in trenches for underground cable protection complete all as specified and as directed |
| 45 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with galvanised strip of size 32 x 6 mm by means of nuts, bolts, check nuts and washers including welding of each joints made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 metre etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 46 | Supply and fixing MCCB 100 Amp, breaking capacity Icu=Ics=25 kA, four pole, 415-volt AC with adjustable thermal release range 80 - 100 Amp with spreader complete all as specified and as directed. |
| 47 | Supply and fixing MCCB 63 Amp, breaking capacity Icu=Ics=25 kA, four pole, 415-volt AC with adjustable thermal release range 80 - 100 Amp with spreader complete all as specified and as directed. |
| 48 | Supply and fix sheet metal enclosure TPN for DB's when MCB's to be used 8 way with 200 amps bus bar and double door complete all as specified and as directed. |
| 49 | Supply and fix enclosure with provision to mount MCCB upto 100 Amps, 50 Ka 'L' frame suitable for wall mounting all as specified and as directed. |
| 50 | Cutting existing concrete/metal/ bituminous road/PCC hard standing or tile walk way any type n.exc 45 cm width and n.exc 30 cm in depth in hard strata and making good disturbed surfaces, matching with PCC(1:4:8) type D2 using 40mm graded stone aggregate including disposal of surplus material to a distance n.exc 50 m, complete all as specified and as directed |
| 51 | M&L,Point wiring using approved colour coding as per IS (Red,Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CML No. Single core multistranded cable in and incoming medium grade surface PVC conduit not less than 20mm dia and accessories ISI marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) with branded modular MS sunken box,frame and outer cover of suitable module for fixing of modular switches,sockets and fan regulators etc. including 1.5 sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire all as specified and as directed for the following |
| 52 | One light point controlled by one switch |
| 53 | One 5 pin 5 Amps socket point controlled by one switch on independent board |
| 54 | All as per item No 51 above but with 2.5 sqmm copper conductor including 2.5 sqmm copper cable as earth wire for one 6 pin 16 Amps socket outlet on independent board complete all as specified and as directed |
| 55 | Supply and fix modular switch 1 way 6 Amps , 1 module |
| 56 | Supply and fix modular socket 6 Amps and 2/3 pin combined 2 module |
| 57 | Supply and fix Socket modular 6A/ 16A -2/3 pin combined 2 module |
| 58 | Supply and fix switch 15A One way SP modular type |
| 59 | Supply and fix ceiling Rose, 3 phase/PVC/Polycarbonate, isolated body |
| 60 | Supply and fix Regal Batten for LED tube light, both side connection type and with ISI marked medium grade LED tube rod of 20 watt, both side connection all as specified and as directed. |
| 61 | Supply and fix MCB 'C' Curve 32 Amp SPN,240 Volts, complete all as specified and as directed. |
| 62 | Supply and fix MCB 'C' Curve SP 6 To 32 Amp SPN,240 Volts, complete all as specified and as directed. |
| 63 | Material and labour for submain wiring with 2 single core 6 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 Volt grade drawn through and including complete and one run of 6 Sqmm PVC insulated unshearthed single core 1100 Volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed. Note: Two run of 6 sqmm size PVC cable, one run of 6 sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length. |
| 64 | Material and labour for submain wiring with 4 single core 6 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 Volt grade drawn through and including complete and one run of 6 Sqmm PVC insulated unshearthed single core 1100 Volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed. Note: Four run of 6 sqmm size PVC cable, one run of 6 sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length. |
| 65 | Supply and fix wall mounted Metal Clad Socket (Industrial Socket) of 32A rating 3P +N+E, 3phase with IP67 degree of protection all as specified and as directed. |
| 66 | Supply and fixing 415V 10KA 'C' curve TPN miniature circuit breaker (MCB) of 40A current carrying capacity in the DB complete with connection testing and commissioning all as specified and as directed. |
| 67 | Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity (Inverter type) with HD filter complete with cordless remote control, 5 star labelled, latest model energy efficent model eco friendly, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled condenser with 100% copper & Goldbin/bluefin coating and 100% copper cooling coil with anti corrosion coating complete all accessories varied speed including fixing the out door unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance as per site requirement, and first charging of refrigerant gas including cordless remote, connection drain lines from unit to nearest drain points complete all as specified and as directed. |
| 68 | Note : - (i) All outdoor units must be installed/ placed in service friendly location /as per the direction of Engr-in-charge. The bidder must visit the site before bidding to ensure feasibility of location to ensure requirement of refrigerant pipes/electrical fittings(ii) The bidder should install the AC by the auth rep of OEM and provide test certificate .(iii) The ACs should have warranty for 10 years on compressor, 05 yrs warranty onPCBs, fan motor (indoor& outdoor) & swing motor and 01 year comprehenssive warranty. In this condition the contractor has to submit the warranty certificate.(iv) Rate for removing and refixing of wall panelling/false ceiling and making good with the existing surface is included in the unit rate.(v) Rate for Core cutting if any required for fixing of indoor unit is included in the unit rate |
| 69 | Supply and fix iD4 Ace 5540 AC Voltage stabilizer, copper wounded suitable for 1.5 TR inverter type split AC, automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and speed of correction 8 volts per second, fixed on wall with necessary arrangements complete all as specified and as directed. |
| 70 | Material and labour for wiring for submain alongwith earthwire of FRLS , PVC insulated copper conductor, single core cable in surface type of size 2x4 sxqmm + 1x4 sqmm earth wire complete all as specified and as directed. |
| 71 | Supply and fix MCB SP upto 32 Amps capacity, 240 volt, 10 KA, 'C' curve complete all as specified and as directed. |
| 72 | Supply and fix MCB protected socket 4 module 20A, metal base, PVC plate (white) color cover plate suitable for upto 2.0 Ton AC with 16A 3 pin top, 20 A SP MCB 16A Scoket duly concealed on the surface/wall including making all electrical connection complete all as specified and as directed. Please Enable Macros to View BoQ information |