| 1 | Note: (i) Please refer Schedule 'A' Notes given in tender documents.(ii) The Schedule 'A' Part-XIV is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col. 5 signifies this fact only. |
| 2 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I. |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-II. |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-III. |
| 6 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-IV. |
| 7 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-V. |
| 8 | Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-VI. |
| 9 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-VII. |
| 10 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII. |
| 11 | Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-IX. |
| 12 | Lump sum price worked out by the contractor for HOT AIR CONDITIONING WORKS carried forward from Pre-Priced Schedule 'A' Part-X. |
| 13 | Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS carried forward from Pre-Priced Schedule 'A' Part-XI. |
| 14 | Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-XII. |
| 15 | MISCELLANEOUS ITEMS OF WORKS (SCHEDULE 'A' PART-XIII)(A) INTERNAL WATER SUPPLY WORKS |
| 16 | S&F of two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia. (flow rate - 8 LPM) , complete all as specified and directed |
| 17 | S&F of Pillar Cock 16 mm dia (Low-flow and flow Rate - 8 LPM), complete all as specified and directed |
| 18 | S & F of Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange chromium plated Stop valves complete all as specified and directed. Make - Jaquar Model No KUP-35053PM or equivalent of makes as specified in tender. |
| 19 | S & F of 15 mm bore Push Cock for urinal for iron pipe and fixed.( PRS-CHR-073) (Low-flow and flow Rate - 3.8 LPF) complete all as specified and as directed. |
| 20 | S & F of Wall Mixer with provisionfFor Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges complete all as specified and directed. Make - Jaquar Model No FUS-29273UPR or equivalent of makes as specified in tender. |
| 21 | (B) INTERNAL ELECTRIFICATION WORKS |
| 22 | S & F modular type TV socket, 1 module co-axial type all as specified and directed by the engineer in charge |
| 23 | Supply and fixing load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with AND INCLUDING incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. Note: Outgoing MCBs shall be measured and paid separately. |
| 24 | Supply and fixing OF 12W Surface down light fitting with 220 V AC and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 25 | Supply and fixing OF 6W Study led light fitting with 220 V AC and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 26 | (C) EXTERNAL ELECTRIFICATION WORKS |
| 27 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type MLTP PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.Make of Panel: Schneider, Siemens, ABB The BUILDING PANEL shall comprise of the following:[A] BUSBAR CHAMBER: [i] 01 Set (3L + N) of copper busbar of rated capacity 200A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING:- [i]160A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set |
| 28 | [C] OUTGOING[i]100A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos (1-CHS PANEL & 1-SPARE)[ii]63A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos(1-APFC PANEL)[iii]40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos (2-PDB 1 & 2 , 1-SPARE)[iv]20A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos (PDB-3 , PDB-4 & PDB 5, )[V] LED phase indicators (Red, Yellow, Blue)- 09 Set |
| 29 | Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type DG PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. Make of Panel: Schneider, Siemens, ABBThe BUILDING PANEL shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 200A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]125A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set |
| 30 | [C] OUTGOING[i] 100A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos (1-CHS PANEL)[ii] 32A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos[ii] 32A, 415 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos[III] LED phase indicators (Red, Yellow, Blue)- 05 Set |
| 31 | Supply of silent type Diesel engine driven generating set with Governing class G2 incl sound reducing canopy (sound level not more than 75 db at a distance of 1 mtr) 14 guage as per latest guideline issued by Ministry of Environment & forest notification, & Central pollution control board 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 160 KVA after considering derating factor at 1600 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to 40 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on Antivibration pads on foundation as recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and vice versa Electric starter motor with batteries, Turbocharger, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 160 kVA all as per as per IS: 13364 and up to date amendments with H class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed.(b) Engine : Water cooled Deisel Engine (CPCB I V Norms Compliance) developing Min 200 BHP or as recommended by the manufacturer for 2100 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. |
| 32 | (c) Canopy : Canopy enclosure shall be powder coated and fabricated after passing through seven tank processes16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arrangement . The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BIS 7888/BS 4375 to prevent excess heat radiation on the engine and safe for operator. Absorption type non‐resistance Residential Silencer shall be provided to suppress exhaust noise from the engine.(d) Alignment and Fuel Tank : Alternator and Engine aligned on a common 14 SWG CRCA MS base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame.(e) Generating Panel :- DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer specifications.Note:-1. Capacity of alternator at 1600 meters altitute -160 kVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized motor. 2. PCC platform as per maufacturer design. |
| 33 | Note:-1. Capacity of alternator at 2400 meters appx altitute -160 KVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized motor. 2. PCC platform as per maufacturer design.3. Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc.4. Engine shall be designed keeping in consideration of de-rating factor for 2100 meters altitute.5. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person.6. DG Set to be tested for 12 Hrs contineously as following. All testing materials and fuel to be provided by the contractor. No Load = 30 Minutes, 25% of Rated load = 1 Hr 50% of Rated load = 1 Hr, 75% of Rated load = 1 Hr, Full load = 2 Hr, 110% on rated Load = 1 Hr, Full load = 2 Hr,75% of Rated load = 1 Hr, 50% of Rated load = 1 Hr, 25% of Rated load = 1 Hr, No Load = 30 Minutes. |
| 34 | (D) HOT WATER SUPPLY WORKS |
| 35 | Supply, installation, testing and commissioning of Monoblock, self-priming, single-stage centrifugal pump, capable of 3 LPS discharge at 20 MWC head,1.5 HP pump having cast iron casing, enclosed type dynamically balanced cast iron impeller, carbon steel pump shaft, gland packed sealing, deep groove ball bearings, etc. with SPDP squirrel cage induction motor having class 'B' insulation, IE2 efficiency, conforming to IS 12615: 2018 and suitable for operation on single-Ph, 210 V±10%, 50 Hz AC supply base plate, mounting channel frame, accessories and fittings, viz. pressure gauges, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting along with accessories complete all as specified and directed. (1 W + 1 S) (MPM 1018 CAT-A, MECHANICAL SEAL). Note:- [i] Necessary civil work viz. foundation for placement of pump and accessories shall be covered in the scope of work. |
| 36 | Supply, Intsallation testing and commissioning of Centralised Water Heater Facility with Water Heating Plant of Capacity 50000 Kcal/Hr, capable of heating 750 litres/hr of water at 2 degrees celcius to 50 degrees celcius in 40 minutes or 65 degrees, as required at site. But when 65 degrees celcius is required, then time may be more for heating), with puffed glass wool/ polyurethene insulation of thickness and density as directed at site by Engineer-In-Charge) over the boiler, boiler tank and pipelines, all covered with aluminium cover, digital temperature controller, electronically controlled burner, water temperature gauge, nylon braided fuel pipes, flue gas chimney and exhausts (insulated with POP ropes), fuel boiler, fuel level indicator, fuel burner, capable of running in Kerosene and Diesel, boards (for instructions, caution and installation names), necessary electnical wiring, necessary GI Gate valves, Gl fittings and Gl medium grade pipes (of any length and bore from existing tank to boiler, from boiler to lower tank and from lower tank to upper tank, from upper tank to bathrooms) complete all as required at site) including polyurethene (covered with aluminium sheet and nylon cable ties) lagging as directed at site by Engineer-In-Charge, including one set of beacons (to indicate plant running) and including a control panel with over current, over voltage protection circuits, Ampere meter, Voltage meter, power factor meter, all with 24 month AMC (all included warranty). Any other necessary fittings, accessories and infrastructure required shall also be provided by Contractor, as per site requirement and as directed by Engineer-In-Charge. The make shall be of THERMAX/ MAKTEK/ RAPIDTHERM/ ECOFLAME/ REILLO/ ZENITH/ WESTERN or equivalent as approved by Engineer-In- Charge. The equipment shall have tolerence for any soil/ dirt/ water in fuel as applicable in field conditions in Army locations in Kashmir valley. In case of any doubt regarding electrical and plumbing requirement, the direction of Engineer-In-Charge shall be final.(2W+1S) |
| 37 | Supply, installation, testing, and commissioning of Fully automatic 1.5 HP DOL starter single phhase, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, complete with all accessories and wiring etc. with ncomplete all as specified and directed. |
| 38 | (D) HOT AIR CONDITIONING WORKS Please Enable Macros to View BoQ information |
| 39 | (D) HOT AIR CONDITIONING WORKS Please Enable Macros to View BoQ information |