| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group 'C' |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 Amp. Switch |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(b) 3 pin 5/6 Amp. Socket outlet |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 9 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 11 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 12 | Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 13 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (b) double pole |
| 15 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 16 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 17 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm 482 DELHI ANALYSIS OF RATES (E&M) 2025 FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (C) 1200 mm, service value ≥ 6.0 CM / Min / Watt, air delivery 210 CM / Min (Minimum) |
| 18 | Supplying, Installation, testing and commissioning of 24 Watt LED 6500K OCTANE+ LED PANEL SQUARE Slim 6500 K, compact, auminum die cast edge lit panel. Recess mounted square fixture with opal diffuser and separate electronic driver Ceiling cutout including connection etc as required. (287x287) mm, height 18 mm ±1 mm for 24 W. |
| 19 | Supplying and fixing of 450 mm sweep, Heavy Duty Exhaust fan Metallic ,1400 RPM fan suitable for single phase, 50 Hz, 230 volts, AC supply in existing opening including making hole to suit the size & S/F of louver / shutter including connection etc as required . |
| 20 | Supplying, Installation, testing and commissioning of Industrial Kitchen Chimney with Baffle Filter Material of Chimney - Stainless Steel 304,Material of Blower Body - Aluminium, Material of Blower Blade - Stainless Steel 304, Material of Exhaust pipe - PVC, Filter Type - Baffle Filter, Control panel Type - Push Button, Exhaust/ Flexible pipe - 3 meter,Shape - Rectangular, Mount Type Island Mounted,In-built light - Yes,Light Type - LED, Wattage of LED - 15 W, Chimney Air Suction Capacity - 3000 cubic mtrs per hour,Exhaust Motor - 1400 RPM,Blower Size -15 inch, Chimney Power Cord Wire Length - 10 Meter, Rated Voltage - Thickness of Chimney Sheet 01 mm, Chimney Height - 60 CM, Chimney Length 210 CM,Chimney Width - 60 CM,Suction Area Length 60 CM,Suction Area width - 60 CM etc as required. Please Enable Macros to View BoQ information |