| 1 | Dismantling of wall and ceiling boards any thickness including corner fillets. |
| 2 | M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre incl 2mm dia G.I. ( upto 1200 mm length ) adjusting level to Purlins/ Rafter. . |
| 3 | M&L 4mm thick non asbestos fibre cement designer building board of size 600X600 fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping. |
| 4 | Dismantling timber scantling 40 sqcm and over in section in any position in framed work. |
| 5 | S & F roof trusses (framed ) trussed, purline , crane gantries , rafter, rails and fastening and heavy brackets framing fast and similar small (beam, Tee, angle , channel plates or flat sections) including distance pieces cleats etc and necessary nuts bolts , rivets, welding, plates etc complete all as specified and directed by Engr-in-Charge Quality confirming to Fe-410-W ( Gde E-250) quality B. |
| 6 | Dismantling AC corrugated /semi corrugated sheets in roof covering complete all as specified and directed. |
| 7 | S & F Pre- painted galvatume aluminum zinc coating GI based corrugated/ Semi Corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 8 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 9 | Demolition of cement concrete (Un reinforced) in ground floors and pavings n. exc 15 CM thickness (below or above ground level) |
| 10 | M & L PCC 1:3:6 type C2 , using 20mm graded aggregates as in 75mm thick plinth protection including bitumen joints in 1.0 Mtr centre to centre as required. |
| 11 | Demolition of Brick work or stone masonry built in cement mortar. |
| 12 | M & L Brick work with sub class `B` bricks straight or covered on plan any radius built in cm 1:6. |
| 13 | Taking down cement plaster on brick or stone wall and any other type of wall finishes incl racking out joints hacking for key, scrubbing down with water and removing the debris from site all as directed. |
| 14 | M & L for rendering in cement mortar (1:6) , 15 mm thick on fair faces of brick work / Concrete /stone surfaces finished even & smooth without using extra cement all as specified and directed by Engr- in - Charge. |
| 15 | M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) with using on wall finishing the surfaces even and smooth without using extra cement. |
| 16 | M&L preparation of new steel surfaces over 10cm in width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 17 | M&L for preparing newly plastered surfaces applying distemper oil emulsion two coats on 3mm thick wall care putty (in two layers) including priming coats complete . |
| 18 | Complete removal of existing treatment of walls/ ceiling and applying two coats of distemper oil emulsion over 3mm wall care putty (in two layers) including priming coats complete . |
| 19 | M&L for preparing the new plastered surfaces of wall and applyingapplying two coats of cement base paint of any colour over one coat primer complete. |
| 20 | M/L Complete removal of existing treatment on wall and applying two coats of cement base paint of any colour over one coat primer complete |
| 21 | Taking down chowkhats or frame exc 1.50 Sqm but n.exc 4 Sqm each with shutter (without taking of shutter from framed) complete. |
| 22 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n’exc1.5 Sqm and removing from site . |
| 23 | M&L Pressed steel frames 125 x 60 mm size of frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed. |
| 24 | M&L Pressed steel frames 105 x 60 mm size of frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed |
| 25 | M&L Providing, cement concrete type B0 1:2:4 (12.5 mm graded aggreate) in filling of pressed steel frame , coping, fixing of hold fast etc similar work. |
| 26 | Supply and fix for Three Track Sliding powder coated aluminium Window of sizes of Top/Side and Bottom track section of 91.80mm x 31.75mm x 1.20mm thick and Shutter section of sizes 39.40 mm x 17.70mm x 1.20mm thick including joining cleats, beading,locking arrangement, rubber gasket for fixing etc complete with 5.5 mm thick tinted glass & stailness steel wire cloth, 0.36 mm nominal dia of wire and averaging width of aperture 1.40mm and fixed with aluminium wire staples complete . |
| 27 | S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 . |
| 28 | M&L for 30 mm thick flush shutters solid core construction,with block board core and plywood face panels,commercial type on both sides including 1mm thick wood grain printed PVC sheet fixed or laid on to flush door by using rubber based adhesive at site as per specification as per SSR Part-I complete all as specified and directed by Engineer-in-charge. complete all as specified as directed. |
| 29 | S&F 30mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. |
| 30 | M & L applying two coats of synthetic enamel paint over a coat of pink primer incl cleaning for new wooden surface. |
| 31 | S&F 250mm Aluminium alloy anodised sliding door with hasp staple (bolts plate type)and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. |
| 32 | S&F 150mm length of bolt aluminium anodized, barrel tower bolt of extruded section and fixed |
| 33 | S&F aluminum handles, cast type ,anodised 150 mm |
| 34 | Dismantaling floor, hearth or wall tiling, including cement mortar bedding (but not backing ) removing serviciable tile to store & rubbish off the permisses. |
| 35 | M&L for 10 mm thick cement plaster in CM (1:4) for backing of tiles complete all as specified and directed. |
| 36 | M&L for coloured glazed ceramic tiles in vertical surface 300x450x7to8mm thick set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces all as specified and directed. |
| 37 | M&L for 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified. |
| 38 | M&L non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.18sqm infloor etc;set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed. |
| 39 | Description all as per Ser Item No 38 as above but on vertical surface as dado/ skirting. |
| 40 | Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor all as directed. |
| 41 | M & L 20 mm thick granite tiles machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in kitchen slab.complete all as specified and directed by Engineer-In- Charge. |
| 42 | Taking up or down steel tubing and connection of 15 mm bore complete all as specified directed at site. |
| 43 | Description all as per Ser item No 42 above but for 20 mm dia bore pipe. |
| 44 | Supplying and laying 20mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 45 | Supplying and laying 25mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 46 | 20mm CPVC Brass Elbow for 'hot or cold' water supply connection and similar works etc,. |
| 47 | 20mm CPVC Brass Tee for 'hot or cold' water supply connection and similar works etc,. |
| 48 | Disconnecting existing tank of capacity exc.500 & n.exc 1000 ltrs, setting aside lowering if required for repairs cleaning etc and hoisting if required reconnecting and refixing in position |
| 49 | S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank 03 layered (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed. |
| 50 | S&F in repair, 15mm bore bib taps cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 51 | S&F for 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 52 | S&F 20mm dia Aluminium powder coated as in golden colour finish draft rod complete all as specified and as approved by EIC. |
| 53 | S&F brass chromium plated decorative bracket fixed to wall . |
| 54 | S&F in repair stainless steel kitchen sink with drainage board 1 mm thick including bedding in cement mortor on to dwarf wall or including fixing centilever brackets over all size 915 mm x 460mm bowl size 410 mm x 330 mm x 160 mm and including 38/40mm dia waiste pipe complete all as specified and directed. |
| 55 | M&L for preparation of old painted steel & iron surface of any description n exc 10 cm width or girth when connected with other painting or when painted in different tint applying two coats of synthetic enamel paint over on steel surface. |
| 56 | Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendents, regulators etc and making good disturbed surface of walls, floors etc complete all as specified & directed by Engineer-in-charge.Note :- Light fittings shall be measured & paid separately. |
| 57 | M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC consealed conduit of 20mm bore with accessories in wall/roof/floor etc, ISI marked with mild steel/prestressed steel modular sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, 3mm thick plastic laminated sheet top cover for mounting switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly completed all as specified and directed by Engr-in-charge for the following . |
| 58 | (a) One light or fan point, controlled by one, one way switch 5 Amps. |
| 59 | (b) One socket out let 3 pin 5 Amps on the same board. |
| 60 | (c) One socket outlet of 3 pin 5 Amp on independent board. |
| 61 | Material and labour for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 2.5 sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC consealed conduit of 20mm bore with accessories in wall/roof/floor etc, and sunken galvanized pressed steel terminal boxes of thickness not less than 1.12 mm covered with 2.80 mm thick phenolic laminated white sheet cover for one 15 amp socket outlet controlled by one switch on independent board incl 1.5 Sq mm copper conductor earth wire and connected to common earth dolly on independent board. |
| 62 | S&F in repair ceiling rose, PVC of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge. |
| 63 | S & F modular switch 1 way 6A, 1 module. |
| 64 | S & F modular switch 1 way 16A, 1 module |
| 65 | S & F modular socket, 6A - 3 pin combined 2 module |
| 66 | S & F modular modular Socket 6A/16A - 3 pin combined 2 module. |
| 67 | S & F modular fan regulator step type, 120W - 2 module |
| 68 | M&L modular white cover plate with frame ( both inner plate & outer plate cover ), 6 module. |
| 69 | M&L modular white cover plate with frame ( both inner plate & outer plate cover ), 8 module. |
| 70 | M&L modular metal flush box 6 module |
| 71 | M&L modular metal flush box 8 module |
| 72 | S&F MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. |
| 73 | S&F MCB single pole & neutral 40 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. |
| 74 | S&F sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 8 way with 200 Amps rated copper bus bar double door type complete all as directed by Engineer-in-charge. |
| 75 | Supplying and fixing LED bulk head fitting 1x 9 watt including connection with PVC insulated flexible flat twin core multi stranded copper conductor cable 0.5 sqmm as required. |
| 76 | Taking down existing earthing and M&L for new Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 5 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. Note : (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 5 of MES SSR Part-I. ii) Item includes the cost of 7.5M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 77 | S&F service connection of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core multistandard cable flat or circular of 10 Sqmm 2 core including taking down old service cable complete all as specified & directed by Engineer-in-charge. (NOTE: Two runs of 10.0 sqmm cable & One run of 10.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length.) |
| 78 | M & L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLS) in PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4 Sq mm (FRLS) of continuous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 6.0 sqmm cable & One run of 6.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length.) |
| 79 | S & F in repair box type fitting 1x 16w, blue coloured end caps, prewired for LED tube including LED tube 16 watts, including connecting up with twin core twisted flexible copper conductor cable with suitable size complete and all as specified and directed by Engineer- in Charge.”. Make: Cromton Greaves Cat part no for Fitting DMLN1LT8-16 and for LED tube LTT8-16 or Equivalent make of Havells/Philips. |
| 80 | Supply and fixing in repair ceiling fans complete with blades down rods ,electronic regulator and accessories, 230V, 1200MM sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five ster rated with brushess direct current motor (BLDC).Note : Old unserviceable fan shall be deposited in store yard by contractor. Engr-in-Charge shall mention ledger No and page No in demolition statement with final bill. |
| 81 | Supply,laying,jointing,testing and commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 95 sqmm 3.5 core connected with aluminium lugs connected by cramping tools complete all as specified and directed at site by Engr-in-charge.Note:- Excavation and earth work will be measured and paid separately. |
| 82 | Description all as per Srl items No. 78 here-in-before but of size 70 sqmm x 3.5 core |
| 83 | Description all as per Srl items No. 78 here-in-before but of size 50 sqmm x 3.5 core |
| 84 | Description all as per Srl items No. 78 here-in-before but of size 25 sqmm x 4 core |
| 85 | Description all as per Srl items No. 78 here-in-before but of size 16 sqmm x 4 core |
| 86 | Excavation of soft/loose soil in trenches not exc. 1.5 m wide and not exec 1.5 mtr in deep for foundation etc. or for shafts,wells,cesspits,mainholes,pierholes etc.in any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in- Charge. |
| 87 | Supply and providing sand cushioning with dry clean sand 08 cm below cable and 15 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
| 88 | Supply and laying unreinforced precast cement concrete cable covers, Class LV, Type-1, with peak, size 250 mm x 150 mm x 40 mm in trenches for cable protection complete all as specified and as directed by the Engineer - in -Charge. |
| 89 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 90 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 91 | Supply and fix in replacement of 80 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed at site. |
| 92 | Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed at site. |
| 93 | Supply and installation testing and commissioning LT Panel out door type, water and vermin proof protection of minimum size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated paint finish both internal and external steel surfaces after necessary preparation of steel surfaces (LT panel shall be of CPRI approved manufacturer) including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment supplied fitted and connected internally complete with bus bar with other accessories complete all as specified and as directed. Note : (i) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (ii) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (iii) The rates shall be deemed to includes the cost of keeping the surface clean and levelled all arround the Feeder piller box and provide INCOMING (a) Copper strip busbar of 300 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos with compatible CTs, Digital ammeter and volt meter with selector switches , set of LED type, indicating lamps R,Y,B on incoming side.(b) MCCB TPN, 415 volt adjustable thermal magnetic release type 250 Amps with breaking capacity 25 KA- 01 No (Incoming ) (ICS=100% ICU)(c) MCCB TPN 415 volt adjustable thermal magnetic release type 125 Amps with breaking capacity 25 KA-02Nos (outgoing) (ICS=100%ICU)(d) MCB TPN 63 Amps Outgoing -01 Nos ( Out going) (ICS = 100%ICU) |
| 94 | Fabricate supply install test and commissioning of Bus bar box out door type totally enclosed dust and vermin proof protection minimum size 900x600x500(Overall domension) mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet CPRI approved test type make including powder coated paint finish including all accessories, provision independent removevable MS plates for fixing cable glands for all incomming and out going cables and complete control wiring with 2.5 sqmm copper conductor incuding necessary PCC foundation complete all specified. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable.(2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (a) (b) MCCB TPN, 415 volt adjustable thermal magnetic release type 100 Amps with breaking capacity 25 KA- 01 No (Incoming ) (ICS=100% ICU)(b) Electrolytic grade aluminium bus bar 300A rating for 3 phase and neutral including PVC colour coded sleves. - 01 Set(c) LED lamps for R,Y,B Phase indication with control fuse/MCB - 01Set.(d ) Volt meter digital type 96 sqmm with selector switch - 01 set.(e) Amps meter digital type 96 sqmm with CT's 200/5 -03 Nos and selector switch - 01 Set(f) Insulators, wiring, bus bar sleeves, lugs, gland, sheet metal enclosure etc including complete wiring with suitable size of copper wire Please Enable Macros to View BoQ information |
| 95 | Fabricate supply install test and commissioning of Bus bar box out door type totally enclosed dust and vermin proof protection minimum size 900x600x500(Overall domension) mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet CPRI approved test type make including powder coated paint finish including all accessories, provision independent removevable MS plates for fixing cable glands for all incomming and out going cables and complete control wiring with 2.5 sqmm copper conductor incuding necessary PCC foundation complete all specified. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable.(2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (a) (b) MCCB TPN, 415 volt adjustable thermal magnetic release type 100 Amps with breaking capacity 25 KA- 01 No (Incoming ) (ICS=100% ICU)(b) Electrolytic grade aluminium bus bar 300A rating for 3 phase and neutral including PVC colour coded sleves. - 01 Set(c) LED lamps for R,Y,B Phase indication with control fuse/MCB - 01Set.(d ) Volt meter digital type 96 sqmm with selector switch - 01 set.(e) Amps meter digital type 96 sqmm with CT's 200/5 -03 Nos and selector switch - 01 Set(f) Insulators, wiring, bus bar sleeves, lugs, gland, sheet metal enclosure etc including complete wiring with suitable size of copper wire Please Enable Macros to View BoQ information |