|
| 1 | BASED ON PWD INTEGRATED BSR 2022 |
| 2 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 4 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge |
| 5 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 6 | P/F reinforcement for RCC work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor five leveTMT bars (Conforming of relevent IS Code). |
| 7 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 8 | Grading roof for water proofing treatment with waterproffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) |
| 9 | Random Rubble Stone masonry super structure up to above plinth level one storey height wall above 30cm thick in cement sand mortar 1:6 mix. |
| 10 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground |
| 11 | Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick. |
| 12 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
| 13 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 14 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade two or more coats on new work including prepration of base with primer putty lippy complete in all respect |
| 15 | Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade : Two or more coats on new work |
| 16 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 17 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paintAdd extra for double leaf shutters. |
| 18 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 19 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 20 | Random rubble dry stone kharanja under floor |
| 21 | Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 graded stone aggregate 40 mm nominal size). |
| 22 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 23 | Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 24 | Short point (up to 3 mtr.) |
| 25 | Medium point (up to 6 mtr) |
| 26 | Long point (up to 10 mtr) |
| 27 | Wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make in surface/reces group - On board |
| 28 | S & F follwing sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. Group-2 20 mm dia |
| 29 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 30 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 31 | P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. Group-2 6 A to 32 A rating |
| 32 | Double pole 6 A to 32 A rating |
| 33 | P & F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with 100 Amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB termination with copper lux, testing etc. as reqd. . group-2 Double door(Single Phase) 8 way |
| 34 | P & F strip fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating/stove enamelled non corrosive UV resist EP channel) complete with accessories(Low loss copperchoke, starter, starter seat)/Electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(Without tube)1x36 watts with OCCB. Group-1 |
| 35 | P & F star rated double ball beari;ng capacitor start, aluminium body and blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep group-1 |
| 36 | P & F IS:371 marked 6 amp sufface type celling rose inculuding making commection testing etc. group-2 |
| 37 | P & F ISI marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required |
| 38 | P&F 240/415 V isolator conforming to IS : 13947-III/ IEC 60947-3 on existing board/ sheet including making connection, testing etc. as required 30 A/ 40 A rating. |
| 39 | P & F socket size flush type 120/280 watt rotary 5 steep fan regulator including making connection testing etc. as required. |
| 40 | Supplying and fixing of power plug point with Modularaccessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with |
| 41 | Plate Earthing as per PWD specification for electrical Worksas per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe,including all accessories like nut, bolts, reducer, nipple,wire meshed funnel, and Heavy duty weather proof poly propylene earth pit chamber with lockable Jam free lid suitable for safeworking load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\"attached with this BSR . Please Enable Macros to View BoQ information |