| 1 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 2 | M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 3 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 200Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 4 | M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 5 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 6 | M & L for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of 1mm thick (average) wall care putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil bound distemper complete all specified and as directed. |
| 7 | M&L for complete removal of existing finishes/treatment of wall by scrapping with mechanical wall sander (mechanical vacuum suction mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc. by skilled labour and applying two coat of oil bound distemper over one coat of primer including 1 mm thick (average) wall care putty using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application complete all as specified and as directed.Note: The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials, i.e paint Distemper, Putty etc is proposed to be used by the contractor and approved by Garrison Engineer. |
| 8 | M&L for preparation of old decorated surfaces of wall and applying one coat of oil bound distemper complete all as specified and as directed. |
| 9 | M&L for preparation of newly plastered surface of walls and applying two coats of acrylic emulsion weather coat paint over one coat of primer complete all as specified and as directed. |
| 10 | M&L for complete removal of existing finishes/treatment of wall by scrapping with mechanical wall sander (mechanical vacuum suction mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc, by skilled labour and applying two coats Acrylic exterior weather coat paint over a priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI, allow 6-8 hrs to dry the surface in both the coats of paint complete all as specified and as directed. |
| 11 | M&L for preparation of old undecorated plaster surfaces of wall and applying One coat of Acrylic exterior weather coat paint with fully automatic airless spray machine of paint application with a flow speed of min 1Litre per minute having a pressure of 3300 PSI complete all as specified and as directed. |
| 12 | M&L for preparation of old undecorated plaster surfaces of wall and applying One coat Acrylic exterior weather coat paint complete all as specified and as directed. |
| 13 | M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant cement primar complete all as specified and as directed. |
| 14 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 15 | M&L for preparation of old decorated surfaces of ceiling and applying one coat of oil bound distemper complete all as specified and as directed. |
| 16 | M & L for preparation of old plastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed. |
| 17 | M&L for preparation of old painted surfaces of wood or wood based materials of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 18 | M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old work with two or more coats complete all as specified and as directed. |
| 19 | M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 20 | M&L for preparation of old painted surfaces of stone, concrete, asbestos cement or plaster surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 21 | M & L for writing letters or figures (Block, Roman, italic or Indian) after cleaning the existing surfaces n.exc 30 cm heigh complete all as specified and as directed. |
| 22 | Grubbing up tree trunk including cutting of trunk portion, girth of tree not exc 30 cm, protruding over ground / building / wall / root / chajja / stack pipes etc. digging out roots, and applying root killer chemical as per manufacturer's instructions, filling holes with cement mortar (1:4) or PCC 1:2:4 type B-0 and removing the unserviceable materials from the site complete all as specified and directed. |
| 23 | Dismantling of 100/110mm bore cast iron/ reinforced concrete drain pipes/ PVC (SWR) pipes, jointed in any type and taking out from wall/ceiling/floor/trenches and any position complete all as specified and as directed. |
| 24 | S&F 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 25 | Refixing only old serviceable 110mm dia PVC (SWR) pipes as obtained from dismantling of old pipe in new or old position to walls, ceiling, flooring etc. complete all as specified and as directed. |
| 26 | Dismantling of 75mm bore cast iron/ reinforced concrete drain pipes/ PVC (SWR) pipes, jointed in any type and taking out from wall/ceiling/floor/trenches and any position complete all as specified and as directed. |
| 27 | S&F 75mm bore PVC (SWR) pipe single socketed in any length and fixed with rubber ring joints to wall including MS clamp complete all as specified and as directed. |
| 28 | Refixing only old serviceable 75mm dia PVC (SWR) pipes as obtained from dismantling of old pipe in new or old position to walls, ceiling, flooring etc. complete all as specified and as directed. |
| 29 | S & F 110 mm dia PVC (SWR) bends of any radius complete all as specified and as directed. |
| 30 | S&F 110 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed |
| 31 | S & F 75 mm dia PVC (SWR) bends of any radius complete all as specified and as directed. |
| 32 | S&F 75 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed |
| 33 | S&F 110mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed. |
| 34 | S&F 75mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed. |
| 35 | S&F 110mm bore PVC (SWR) branch piece , single (single Y) equal or unequal with access door complete all as specified and as directed |
| 36 | S&F 110mm bore PVC (SWR) branch piece , single (double Y) equal or unequal with access door complete all as specified and as directed |
| 37 | S & F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 38 | S&F in repairs, 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. Please Enable Macros to View BoQ information |