| Sl. No. | Item Description |
| 1 | SUB-HEAD : EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 3 | All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 5 | All kinds of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | All kinds of soil |
| 8 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 9 | Extra for additional lift of 1.5m or part thereof. |
| 10 | All kinds of soil |
| 11 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 12 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 13 | Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 14 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment as per IS: 6313 (Part III)- Latest revision (excluding the cost of chemical emulsion): |
| 15 | (i) Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: |
| 16 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 17 | SUB-HEAD : CEMENT CONCRETE WORK |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering |
| 19 | All work upto plinth level: |
| 20 | 1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size) |
| 21 | 1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded stone aggregate of 20 mm nominal size) |
| 22 | 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded stone aggregate of 20 mm nominal size) |
| 23 | 1:5:10 ( 1 Cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size) |
| 24 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 25 | Foundations, footings, bases for columns. |
| 26 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification |
| 27 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 28 | SUB-HEAD : RCC WORK |
| 29 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: |
| 30 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 31 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- |
| 32 | 1 : 1.5 : 3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate of 20 mm nominal size) |
| 33 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- |
| 34 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 35 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 36 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 37 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 38 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 39 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size). |
| 40 | Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits. |
| 41 | 50 mm thick |
| 42 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 43 | Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 44 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply |
| 45 | Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 46 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 47 | Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 48 | Stairs (excluding landings) except spiral-staircases with wooden plank |
| 49 | Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. |
| 50 | Edges of slabs and breaks in floors and walls under 20 cm. wide |
| 51 | Weather shade, Chajjas, corbels etc., including edges. |
| 52 | Providing and fixing in position Stainless steel Grade 304 plate- 1.0 mm thick as per design for expansion joints. |
| 53 | 200mm wide |
| 54 | Providing and fixing sheet covering over expansion joints with iron screws as per design to match the colour / shade of wall treatment |
| 55 | Aluminium fluted strips 3.15 mm thick: 200 mm wide |
| 56 | Smooth finishing of the exposed surface of R.C.C. work with 6mm thick cement mortar 1:3 (1 Cement: 3 fine sand) |
| 57 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 58 | SUB-HEAD : BRICK WORK |
| 59 | First class brick work in foundation and plinth including cost of all materials as required complete. |
| 60 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 61 | In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 62 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete. |
| 63 | In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 64 | Half brick masonry with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- |
| 65 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 66 | Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course of half brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:- |
| 67 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 68 | SUB-HEAD : MARBLE WORK |
| 69 | Providing and fixing gang saw cut of approved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 ( 1 cement : 4 fine sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing , curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels:- |
| 70 | 14 mm thick Rajnagar Plain white marble/ Udaipur green marble/ Zebra black marble or equivalent duly approved:- |
| 71 | Area of slab upto 0.50 sqm. |
| 72 | 14 mm thick Granite of any colour and shade duly approved:- |
| 73 | Area of slab upto 0.50 sqm. |
| 74 | Providing edge moulding to approved thickness marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete at all levels as required as per design approved by the Engineer-in-charge:- |
| 75 | 14 mm thick Marble work. |
| 76 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 77 | Providing and fixing stone slab with table rubbed, edges rounded and polished of size 75x50 cm deep and approved thickness fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth including rubbing, curing etc. complete at all levels as required (measurement should be of exposed finished work):- |
| 78 | White Agaria Marble Stone of approved shade of 14 mm thick (75 x 50 cm). |
| 79 | SUB-HEAD : WOOD WORK |
| 80 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/ Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 81 | Frame size 65 x 125 mm |
| 82 | Frame size 65 x 100 mm |
| 83 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) |
| 84 | 25 mm thick |
| 85 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass (weight not less than 10ks/Sqm) panes including black enamelled ISI marked MS butt hinges with necessary screws. |
| 86 | Local Teak wood |
| 87 | 35 mm thick |
| 88 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or croos bands and face venners on both faces of shutters. |
| 89 | 35mm thick including ISI marked stainless steel butt hinges with necessary screws |
| 90 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. |
| 91 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 92 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 93 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 94 | 300x16 mm |
| 95 | 250x16 mm |
| 96 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 97 | 300x10 mm |
| 98 | 250x10 mm |
| 99 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 100 | 125mm |
| 101 | 100mm |
| 102 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 103 | Single rubber stopper |
| 104 | Providing 50 × 50 × 50 mm Gamair wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement: 3 fine sand) and making good the walls etc. |
| 105 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 106 | SUB-HEAD : STEEL WORK |
| 107 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 108 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 109 | Hot finished welded type tubes |
| 110 | Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design. |
| 111 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- |
| 112 | In grating, frames, guard bar, railing, brackets, gates and similar works, all complete. |
| 113 | Providing and fixing MS bolts including nuts and washers complete as per standard design:- |
| 114 | Upto 300mm length. |
| 115 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required. |
| 116 | Providing and fixing M.S. fan clamp of type I of 16 mm M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting exposed portion of loop, all complete as per standard design as per standard design complete. |
| 117 | SUB-HEAD : ALUMINIUM WORK & STRUCTURAL GLAZING |
| 118 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :- |
| 119 | (i) For fixed portion of approved quality:- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 120 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):- |
| 121 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 122 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- |
| 123 | With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
| 124 | With float glass panes of 5.5 mm thickness ( weight not less than 13.75 kg / sqm ) |
| 125 | Filling the gap in between aluminium frame and adjacent RCC/brick work by providing weather silicon sealant over backer rod of approved quality etc. complete as per architectural drawing and direction of the Engineer-in charge:- (i) Upto 5 mm depth and 5 mm width. |
| 126 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. of approved quality complete as per direction of Engineer-in-charge:- |
| 127 | Anodised aluminium of grade AC 15 |
| 128 | Providing and fixing stainless steel (SS 304 grade) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-in-charge (1) 255 x 19 mm |
| 129 | Providing and fixing 100 mm brass locks ( best make of approved quality ) with 6 levers without pair of handles for aluminium doors including necessary cutting and making good etc. complete as per direction of Engineer-in-charge. |
| 130 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of aluminium composite panel material of approved thickness and specification. The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. |
| 131 | (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.\\" |
| 132 | Aluminium Composite Panels of 4mm total thickness with Top coil – 0.50mm AA3003 / AA3105 / AA5005 Grade manufactured as per IS-737 1986, FR Grade Class B1 with 3mm Mineral Core with minimum 70-72% Inorganic content (Aluminium Hydroxide and Magnesium Hydroxide) 28-30% Organic content (LDPE) conforming to ASTM E-119-16,18 and EN 13501-1, class B1,and Bottom coil – 0.50mm AA3003 / AA3105 / AA5005 Grade, manufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4 - 6 microns) having minimum panel weight of 7.5 Kg/m2 |
| 133 | SUB-HEAD : FLOORING AND SKIRTING WORK |
| 134 | Providing and laying Mirror Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 fine sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 135 | 14 mm thick stone slab. |
| 136 | Providing and laying Mirror Polished Granite stone flooring in treads of steps & risers and skirting in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 fine sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 137 | 14(+2) mm thick stone slab (using single length upto 2.00m). |
| 138 | Providing edge moulding to approved thickness granite stone counters, vanities, treads of steps etc. including machine polishing to edge to give high gloss finish etc. complete at all levels as required as per design approved by the Engineer-in-charge.i) 14 mm thick Granite work |
| 139 | Providing and fixing Marble stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.14 mm thick Marble stone |
| 140 | Raj Nagar plain marble |
| 141 | Providing and laying 1st class ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete.Mat Finish Tiles/Anti-Skid Tiles/Glossy tiles |
| 142 | Mat Finish Tiles/Anti-Skid Tiles/Glossy tiles - 600 mm x 600mm in all shades and designs 1st class quality ceramic floor porcelain tiles. |
| 143 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer in-charge. |
| 144 | Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 145 | Size of tile 1200 mm x 600 mm |
| 146 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622 - 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-charge |
| 147 | Soluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 148 | Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. all complete as per direction of Engineer in-charge. |
| 149 | 40mm thick. |
| 150 | Providing and fixing 25 mm thick wooden planking, tounged and grooved in floors including fixing with iron screws etc. all complete as per direction of Engineer-incharge. |
| 151 | With Teak wood local |
| 152 | Providing and fixing Kota stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with ordinary cement mixed with pigment of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge. |
| 153 | Kota stone slab 25mm thick |
| 154 | Providing and fixing precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning complete as per direction of the Engineer-in-Charge. |
| 155 | In dark shade using ordinary cement |
| 156 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge. |
| 157 | 450 mm x 300 mm in all shades and design |
| 158 | SUB-HEAD : ROOFING AND CEILING WORK |
| 159 | Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge. |
| 160 | 0.50mm thickness |
| 161 | Supply & installation of pre-painted Galvalume sheets roofing accessories in 550mpa steel steel grade, made out of Cold rolled steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to AASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. The sheet shall be fixed using self drilling /self tapping screws with EPDM washers complete for Ridges/Valley/Gutter/Flashing of width 610mm: |
| 162 | 0.50mm thickness |
| 163 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45 x15 x 0.90mm running at the spacing of 1200 mm c/ c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & |
| 164 | including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with: |
| 165 | 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 166 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: |
| 167 | Single socketed pipe -110 mm OD |
| 168 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : |
| 169 | (i) Coupler - 110mm |
| 170 | (ii) Single equal tee without door - 110 x 110 x 110 mm |
| 171 | (iii) Single equal tee with door - 110 x 110 x 110 mm |
| 172 | (iv) Bend 87.5o - 110mm |
| 173 | (v) Plain shoe - 110 mm |
| 174 | Providing and fixing 25mm x 1.40 mm clips made out of aluminium strip of approved design to unplasticised - PVC rain water pipes by means of Plastic Wall Plugs fitted in the brick work/R.C.C work by drilling with the help of mechaine and screwed with M.S. screws of required length and making good the wall etc. complete as per direction of Engineer-in-charge. |
| 175 | 110mm |
| 176 | Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. Complete as per direction of Engineer-in-charge |
| 177 | 100mm |
| 178 | SUB-HEAD : FINISHING WORK |
| 179 | 12 mm cement plaster of mix |
| 180 | In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 181 | In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 182 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
| 183 | In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 184 | 6 mm cement plaster of mix: |
| 185 | In cement mortar 1 : 3 ( 1 cement : 3 fine sand ) |
| 186 | Neat cement punning. |
| 187 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : |
| 188 | New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 189 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 190 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. |
| 191 | Two coats |
| 192 | Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : |
| 193 | (i) New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 194 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : |
| 195 | With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 196 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 197 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work |
| 198 | SUB-HEAD:WATER PROOFING WORK |
| 199 | Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with : |
| 200 | Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 201 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound, as directed by Engineer-in-Charge and consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 202 | SUB-HEAD : SANITARY INSTALLATIONS |
| 203 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 204 | White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 205 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 206 | W.C. pan with ISI marked white solid plastic seat and lid |
| 207 | Providing and fixing White vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively |
| 208 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 209 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings: |
| 210 | Flat back wash basin of size 550x400mm. |
| 211 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 212 | (i) Semi rigid pipe - 32 mm dia |
| 213 | (ii) Flexible pipe - 32 mm dia |
| 214 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 215 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 216 | Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms |
| 217 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. |
| 218 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: |
| 219 | Single socketed pipe - 110 mm OD |
| 220 | Providing and fixing 25mm x 1.40 mm clips made out of aluminium strip of approved design to unplasticised - PVC soil, waste & vent pipes by means of Plastic Wall Plugs fitted in the brick work/R.C.C work by drilling with the help of mechaine and screwed with M.S. screws of required length and making good the wall etc. complete. |
| 221 | 100 mm |
| 222 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste & vent pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : |
| 223 | (i) Coupler - 110mm |
| 224 | (iv) Single equal tee with door - 110 x 110 x 110 mm |
| 225 | (iii) Single equal tee without door - 110 x 110 x 110 mm |
| 226 | (v) Double equal junction of required degree without door - 110 x 110 x 110 x 110 mm |
| 227 | (vii) Bend 87.5o - 110mm |
| 228 | (viii)Terminal guard: - 110 mm |
| 229 | Providing and fixing to the inlet mouth of soil, waste & vent pipes pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete. 100 mm |
| 230 | Providing and fixing SS grabbars set for accessible toilets comprising of 4 No. Grabbars as specified:(1 NO. wing grabbar + 1 NO. Lshaped grabbar + 2 No. straight grabbars= 1 typical set)a) Swing grabbar (1 NO) Providing a S.S.304 SWING HANDICAP GRABBAR-700mm and of DIA:32MM and thickness 1.5 mm of the roved brand and make.b) L shaped grabbar (1 NO) Providing S.S304 LSHAPED DISABLED GRABBAR of SIZE-600MM (H)X600MM(D) and 32MM DIA and thickness 1.5mm of the approved brand and make.c) Straight grabbar (2 NO) Providing S.S.304 GRAB RAIL (600 MM), 32MM DIA and thickness 1.5mm of the approved brand and make. |
| 231 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4(1cement: 4 coarse sand): |
| 232 | 100mmdia. |
| 233 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 234 | Kitchen sink without drain board610x460 mm bowl depth 200 mm. |
| 235 | SUB-HEAD : WATER SUPPLY |
| 236 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 237 | 15 mm nominal outer dia .Pipes. |
| 238 | 20 mm nominal outer dia .Pipes. |
| 239 | 25 mm nominal outer dia .Pipes. |
| 240 | 40 mm nominal outer dia .Pipes. |
| 241 | Providing and fixing brass bib cock of approved quality : |
| 242 | 15 mm nominal bore |
| 243 | Providing and fixing brass stop cock of approved quality : |
| 244 | 15 mm dia nominal bore |
| 245 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): |
| 246 | 25 mm nominal bore |
| 247 | 40 mm dia nominal bore |
| 248 | Providing and fixing gun metal non-return valve of approved quality (screwed end): |
| 249 | 40 mm nominal bore |
| 250 | Vertical |
| 251 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 252 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:5 (1 cement :5 fine sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : |
| 253 | With Second class bricks |
| 254 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: |
| 255 | 100 mm diameter |
| 256 | SUB HEAD : SEWAGE AND DRAINAGE WORKS |
| 257 | Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete : |
| 258 | 150 mm diameter |
| 259 | Providing and laying cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design: |
| 260 | 150 mm diameter S.W, pipe |
| 261 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with well burnt 2nd class bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 262 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : |
| 263 | Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 264 | SUB HEAD : PAVER BLOCK WORK |
| 265 | 80 mm thick factory made c.c. interlocking paver block of M-35 Grade. Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength, thickness & size/ shape, made by table vibratory method to attain superior smooth finish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge.(a) 80 mm thick c.c. paver block of M-35 grade with approved colour, design and pattern. |
| 266 | SUB HEAD : DWS (SUBMERSIBAL) |
| 267 | Drilling and boring pilot hole in any soil strata by manual means, collection of soil samples of different strata met with during drilling at variuse suitable levels, preservation of samples in polythene bags/ sample box and disposal o excess soil or mud, including the cost of water etc, as required to mantain the pilot hole properly as pespecification and direction of the Engineer-in charge. |
| 268 | Reaming of pilot hole to an enlarged bore hole in any soil strata by manual means, disposal of excess soil or mud, including the cost of water etc, as required to mantain the pilot hole properly as per specification and direction of the Engineer-in charge |
| 269 | Providing and lowering of PVC pipe of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer-in-charge.A) CM Casing pipe (UPVC) |
| 270 | i) 150mm dia |
| 271 | ii) 100mm dia |
| 272 | A) RS pipeii) 100mm dia |
| 273 | Providing and fixing of UPVC end cap/ well cap suitable for UPVC 'CM' casing or 'CS' casing or RS pipe as per specification and direction of the Engineer in charge. i) 100mm dia |
| 274 | Providing and fixing of UPVC reducer suitable for UPVC 'CM' casing or 'CS' casing or RS pipe as per specification and direction of the Engineer in charge. SOR-2015, DWS, i) 150 x 100mm dia |
| 275 | Providing and shrouding of the deep tube well assembly with washed pea gravels (2.0 - 4.75 mm effective size) as per specification (IS: 4097) and direction of the Engineer in charge. |
| 276 | Washing and development of tube well by using hand pump or by any suitable method and testing of the well as per specification and direction of the Engineer in charge |
| 277 | Providing and fixing if housing clamp (made with 12 mm thick MS sheet) along with well cap (made with 10mm thick MS sheet) with necessary arrangement for SBDTW as per specification and direction of enginner-in-charge. |
| 278 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitsb;e for DIN fuse ),tripple pole with neutral link (TPN),current range 100 amps,415/500 volts,L&t/havells/HPL make etc complete as per specification and direction of the engineer -in -charge .(a) 32 amps (SBDTW) |
| 279 | Supplying & fitting fixing of panal box of MS sheet with locking arrangement comprise with starter, main switch,busber volt meter selector switch etc etc. inside the box in/c sevice connection within 50.00 mtr length from LT line with roof for rain water protector and 4 nos stand by c.c. work in all respect as per direction of the engineer in charge. |
| 280 | Supplying and installation of water lubrication subermissible pump of Duke make (model no. DSP4RFH05) having capacity 2000 GPH at total head of 45 mtr .Coupled with submersible motor suitable for 240 volts (+10 % verification) single phase 50HP .AC supply DOL starting method to run at 2880 RPM along with 35mtr 2.5 SQM ,PVC installated 3core flat cable conforming to IS code and cable in/c fitting ,fixing and lowering 40mm dia GL pipe upto 100 ft (30m) etc complete as per direction of engineer-in- charge |
| 281 | Providing and Fitting fixing of different capacity 230 volt, single phase submersible pump starter BCH/L&T,AB make as per specification and direction of engineer-in- charge. 1) 2 HP Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail