| 1 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :First grade Sal wood (Weight of sal wood should be 865 Kg/M³ & wood should be confirming to IS:399:1963) |
| 2 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :Second class Sal wood (Weight of sal wood should be 865 Kg/M³ & wood should be confirming to IS:399:1963) |
| 3 | Providing and fixing glazed shutters for windows using 4mm thick glass of Modi float /Golden/Atul/Saint Gobain including black enamelled ISI marked M.S. butt hinges with necessary screws- Second Grade Teak wood (C.P. Teak wood confirming IS-399:1963, Weight of C.P. Teak Wood should be 640 Kg/M³) .Second class teak wood 35 mm thick |
| 4 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 18 mm |
| 5 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 6 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16mm |
| 7 | Providing and fixing ISI marked aluminium tower bolts ISI marked anodised (anodic coating not less then grade AC 10 as per IS : 1868 ) transparent or dyed to required coulor or shad with nuts and screws etc. complete: 200x10mm |
| 8 | Providing and fixing ISI marked aluminium tower bolts ISI marked anodised (anodic coating not less then grade AC 10 as per IS : 1868 ) transparent or dyed to required coulor or shad with nuts and screws etc. complete: 100x10 mm |
| 9 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125 mm |
| 10 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 75 mm |
| 11 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 12 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. make TATA/Jindal make . |
| 13 | 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class deodar wood |
| 14 | Provinding and Fixing Wind Ties of 40x6 mm Flat iron saction |
| 15 | Providing and fixing plain multipurpose cement board (High Pressure steam cured) as per IS: 14862 : 2000) with suitable fibre cement screw in ceiling etc. complete (frame work to be paid seprately) 6mm thick cement board |
| 16 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 17 | Applying priming coat :With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 19 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 20 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 21 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
| 22 | supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 23 | Supplying and fixing 63 amps. rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps Please Enable Macros to View BoQ information |