Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CARRIAGEDisposal of excavated earth/ moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. |
| 2 | EARTH WORKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 min width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. : All kinds of soil. |
| 4 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc, not exceeding 80 mm dia. |
| 5 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia : Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | Supplying and filling in plinth with sand under floors including, watering, ramming consolidating and dressing complete. |
| 8 | CONCRETE WORK ;Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 11 | REINFOCEMENT CEMENT CONCRETE WORKProviding and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centring, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Small lintels not exceeding 1.5 m clear span, moulding as incornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shed, Chajjas, corbels etc., including edges |
| 23 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6 mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, rougheningcleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. : 50 mm thick |
| 24 | Steel Reinforcement for RCC work including straightening cutting bending placing in position and binding all complete up to plinth and above plinth level for TMT Bars. |
| 25 | Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard settingof concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content indesign mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement : All works above plinth level upto floor levl V : Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 26 | Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard settingof concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content indesign mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement : Add for using extra cement in the items of design mix over and above the specified cement content therein. : All works above plinth level upto floor levl V ; Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 27 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 29 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) : Cement mortar 1:4 (1 cement :4 coarse sand) |
| 30 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 31 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 32 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 33 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade : Granite stone slab of colour black, Cherry/Ruby red ; Area of slab over 0.50 sqm |
| 34 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. ; Granite Work |
| 35 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 36 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 37 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete : 8 mm thick : Granite of any colour and shade |
| 38 | Providing and Fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 39 | WOOD AND PVC WORK :Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length : Sal wood |
| 40 | Providing and fixing glazed shutters for doors, windows and clerestorywindows using 4 mm thick float glass panes (weight not less than 10 kgper sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws ; Second class teak wood 30 mm thick |
| 41 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 42 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws |
| 43 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 44 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets |
| 45 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to framewith 10 mm diameter bolts, nuts and wooden plugs and embedding incement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 46 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 47 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 48 | Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete ; Size 50 mm |
| 49 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16mm |
| 50 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10mm |
| 51 | roviding and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10mm |
| 52 | Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete. |
| 53 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 54 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm |
| 55 | Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868transparent or dyed to required colour and shade, with necessary screws etc. complete. ; Twin rubber stopper |
| 56 | Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc.complete. |
| 57 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. : magnetic catcher Double strip (horizontal type) |
| 58 | Providing and fixing wire gauge shutters using stainless steel grade 304wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood |
| 59 | Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm(± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm havingwall thickness 2 mm (±0.2 mm), including providing & fixing3 nos of 125mm long stainless steel hinges to the frame, fixing the frame with jambwith required number & size of anchor dash fastners, all complete as per manufacturer’s specification and direction of Engineer-in-charge |
| 60 | Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (± 0.2 mm), with inbuilt bead on oneside, styles and railsmitered cut and joint at the corners by means of 2 nos of plastic bracketsof size 75 mm x 220 mm at each corner and stainless steel screws,reinforcing the hinge side of style by inserting PVC profile of size 28 mmx 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mmx 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts andwashers complete, all as per manufacturer’s specification and direction of Engineer-in-charge |
| 61 | Providing and fixing factory made UPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash andmullion/coupler (where ever required) extruded profiles having minimumwall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mmfor Series R3 and R4 profiles conforming to EN: 12608 in any shape,colour and design duly reinforced with galvanized mild steel sectionmade of required shape & size as per CPWD Specification, uPVCextruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS304 grade fasteners of minimum 8 mm dia with countersunk head,comprising of matching polyamide PA6 grade sleeve for fixing frameto finished wall as per IS 1367 : Part 1 to 14, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash &mullion (if required) shall be mitred cut and fusionwelded/mechanicallyjointed duly sealed at all corners, including drilling of holes for fixinghardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof siliconsealant over backer rod of approved size and quality, all complete asper approved drawing conforming to CPWD specification & direction ofEngineer-in-Charge. Section of steel reinforcement and cross sectionsof uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unitwith / without high performance coatings as per design requirements andconforming to IS: 3548 & IS: 16231 shall be paid separately.Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track,wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body.x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (85 mm & above). (Height above 2.5 metre). |
| 62 | Fixed window / ventilator without mullion / transom. : Using R3 series with frame (55 mm & above) x (45 mm & above). (Height upto 2.5 metre) |
| 63 | Casement door double panel with French (False) Mullionwith zinc alloy (zamak) 3D hinges, multi-point locking systemwith cylinder, zinc alloy (zamak) powder coated handles onboth sides.Using R4 series with frame (64 mm & above)x (55 mm & above) & sash (64 mm & above)x (100 mm & above) & French (False) mullion (64 mm & above) x (60 mm & above). (Height above 2.5 metre). |
| 64 | Providing and fixing 19 mm thick both side balancing laminationfactory pressed BWP grade marine ply as per IS : 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-incharge. |
| 65 | Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. ; 20mm |
| 66 | Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per direction of Engineer- in-charge. |
| 67 | Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-incharge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) |
| 68 | Steel Work :-Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. MS Steel frame work in false ceiling (1200X 600X 275 box) |
| 69 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer : Using M.S. angels 40x40x6 mm for diagonal braces |
| 70 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 71 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side of waistslab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners |
| 72 | FLOORING Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. ; 40 mm thick with 20 mm nominal size stone aggregate |
| 73 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 74 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades,laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. ; Size of Tile 600x600 mm |
| 75 | Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. ; Size of Tile 600x600 mm |
| 76 | Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. : Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent |
| 77 | ROOFING Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete : 1.60mm thick with zinc coating not less than 350 gm/m2 |
| 78 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 100 mm diameter |
| 79 | Providing and fixing false ceiling at all heights including providing andfixing of frame work made of special sections, power pressed from M.S.sheets and galvanized with zinc coating of 120 gms/sqm (both sideinclusive) as per IS : 277 and consisting of angle cleats of size 25 mmwide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centreto centre, one flange fixed to the ceiling with dash fastener 12.5 mm diax 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the anglehangers of 25x10x0.50 mm of required length with nuts & bolts of requiredsize and other end of angle hanger fixed with intermediate G.I. channels45x15x0.9 mm running at the spacing of 1200 mm centre to centre, towhich the ceiling section 0.5 mm thick bottom wedge of 80 mm withtapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centreto centre, shall be fixed in a direction perpendicular to G.I. intermediatechannel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick27 mm high having flanges of 20 mm and 30 mm long, the perimeter ofceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,with 25 mm long dry wall screws @ 230 mm interval, including fixing ofgypsum board to ceiling section and perimeter channel with the help ofdry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing andfinishing to a flush finish of tapered and square edges of the board withrecommended jointing compound , jointing tapes , finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and twocoats of primer suitable for board, all as per manufacturer’s specificationand also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed,all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board |
| 80 | Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-Charge) of totalcoated thickness 0.50 mm (base metal of minimum 0.45 mm thicknesswith total coating thickness of 0.05mm) with zinc coating 120 grams persqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns. Sheet shouldhave protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixedusing self drilling /self tapping screws of size (5.5x 55 mm) with EPDMseal, complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 81 | Providing and fixing precoated galvanised steel sheet roofing accessoriesof total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridge plan (500-600 mm) |
| 82 | FINISHING WORKS12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 83 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) sqm |
| 84 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 85 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 86 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90litre/10 sqm) |
| 87 | Painting Steel work with Deluxe Multi Surface Paint to give aneven shade. Two or more coat applied @ 0.90 ltr/10 sqm over and under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 88 | Applying priming coat : with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 89 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 90 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 91 | ROAD WORKProviding and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. : 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 92 | SANITATRY INSTALLATIONSProviding and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixturescomplete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 93 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 94 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 95 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perIS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board : 510x1040 mm bowl depth 225 mm |
| 96 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 97 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. : Flexible pipe : 32 mm dia |
| 98 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. : Flexible pipe : 40 mm dia |
| 99 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 100 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 101 | Providing and fixing toilet paper holder : C.P. brass |
| 102 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. : 600 mm long towel rail with total length of 645 mm, width 78mm and effective height of 88 mm, weighing not less than 190 gms. |
| 103 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litre with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 104 | WATER SUPPLYProviding and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on walls : PN - 16 Pipe, 25 mm OD (SDR-7.4) |
| 105 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on walls : PN - 16 Pipe, 32 mm OD (SDR-7.4) |
| 106 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes confirming to IS:15801, UV stabilized & anti - microbial fusionwelded, having thermal stability for hot & cold water supply, including allPP - R plain & brass threaded polypropylene random fittings and fixingthe pipe with clamps at 1.00 m spacing. This includes the cost of cuttingchases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. : PN - 16 Pipe, 20 mm OD (SDR-7.4) |
| 107 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes confirming to IS:15801, UV stabilized & anti - microbial fusionwelded, having thermal stability for hot & cold water supply, including allPP - R plain & brass threaded polypropylene random fittings and fixingthe pipe with clamps at 1.00 m spacing. This includes the cost of cuttingchases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. : PN - 16 Pipe, 25 mm OD (SDR-7.4) |
| 108 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work : PN - 16 Pipe, 32 mm OD (SDR-7.4) |
| 109 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work : PN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 110 | Providing and fixing PPR Unions : PPR Union 25mm |
| 111 | Providing and fixing PPR Unions : PPR Union 32mm |
| 112 | Providing and fixing PPR Unions : PPR Union 40 mm |
| 113 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). : 25 mm nominal bore |
| 114 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). :32 mm nominal bore |
| 115 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). ; 40 mm nominal bore |
| 116 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore 25 mm nominal bore |
| 117 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length : 15 mm nominal bore |
| 118 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter : 150 mm diameter |
| 119 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 120 | Providing and fixing CP brass bib cock of approved quality confirming to IS 8931 : 15 mm nominal bore |
| 121 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. : 15 mm nominal bore |
| 122 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : 15mm nominal bore |
| 123 | Providing and fixing PTMT soap Dish Holder having length of 138 mm,breadth 102 mm, height of 75 mmwith concealed fitting arrangements, weighing not less than 106 gms. : |
| 124 | DRAINAGE Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter |
| 125 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 200 mm diameter S.W. pipe |
| 126 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside)150 x 100 mm size P type the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 127 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and makingchannels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 128 | Constructing brick masonry road gully chamber 45x45x77.5 cm withbricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 129 | Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarsesand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stoneaggregate 40 mm nominal size), inside plastering 12 mm thick withcement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with afloating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for singlepipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 130 | Extra for depth beyond 45 cm of brick masonry chamber :For 455x610 mm size With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 131 | Aluminium Work Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete asper the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 132 | WATER PROOFING Providing and laying water proofing treatment in sunken portion ofWCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 133 | CONSERVATION OF HERITAGE BUILDINGSProviding and fixing double scaffolding system (cup lock type) on theexterior side of building/structure, upto 25 metre height, above groundlevel, including additional rows of scaffolding in stepped manner as perrequirement of site, made with 40 mm dia M.S. tube, placed 1.5 metrecentre to centre, horizontal & vertical tubes joint with cup & lock systemwith M.S. Tubes, M.S. tube challis, M.S. clamps andstaircase system inthe scaffolding for working platform etc. and maintaining it in a serviceablecondition for execution of work of cleaning and/ or pointing and/ orapplying chemical and removing it thereafter. The scaffolding systemshall be stiffened with bracings, runners, connecting with the building etc,wherever required, if feasible, for inspection of work at required locationswith essential safety features for the workmen etc., complete as perdirections and approval of Engineer-in-charge. Note1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment willbe made once only for execution of all items for such works |
| 134 | Ruled/ Flush pointing on White sand stone masonry surface with lime,surkhi and marble dust mortar in the ratio of 1:1.5:1/2 {One lime : 1.5surkhi (15% dark red and 85% light yellow surkhi) : 1/2 marble dust}. (The rate is inclusive of all materials & labours involved except scaffolding). |
| 135 | NEW TECHNOLOGIES AND MATERIALS Providing and fixing false ceiling at all heights with integral densifiedcalcium silicate reinforced with fibre and natural filler false ceiling tiles ofSize 595x595 mm of approved texture, design and patterns having NRC(Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987,Light reflectance of 85% (minimum). Non combustible as per BS:476(part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondaryintermediate cross-T of size 15x42 mm of length 600 mm to form gridmodule of size 600 x 600 mm, suspended from ceiling using galvanisedmild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hangerrod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help ofplastic rawl plugs at 450 mm center to center and 40 mm long dry wallS.Sscrews. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. : With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles |
| 136 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (SuspensionGrade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement andscrewed with full body threaded star headed SS screws having minimumframe density of 750 kg/cum, screw withdrawal strength of 2200 N (Face)& 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulusof elasticity 900 N/mm2 and resistance to spread of flame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SSdash fasteners of required dia and length complete as per direction ofEngineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall bepaid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance indimensions i.e depth and width of profile shall be acceptable. Variation inprofile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 100 mm |
| 137 | Providing and fixing factory made single extruded WPC (Wood PolymerComposite) solid decorative type flush door shutter of required sizecomprising of virgin polymer of K value 58-60 (Suspension Grade),calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)having minimum density of 650 kg/cum and screw withdrawal strengthof 1800 N (Face) & 900 N (Edge), minimum compressive strength 50N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A category with property of being termite/borer proof,water/moisture proof and fire retardant. WPC to be laminated with PVCfoil of minimum 14 microns thick of approved design pasted with hotmelt adhesive on both faces of shutter and fixing with stainless steel butthinges of required size with necessary full body threaded star headedcounter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) ; 30 mm thick |
| 138 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. : Granite Stone of approved shade |
| 139 | NON SCHEDULE ITEMS :Providing and fixing white vitreous china flat back single half stall urinal of size 580x380x350 mm with Angle valve, fittings, standard size C.P. brass flush pipe, spreaders with unions and gratings (all in C.P. brass), cutting and making good the walls wherever required as per direction of Engineer-in-charge. : |
| 140 | Providing and fixing M.S. sheet of 1.6 mm thickness in eave board, chajjas, ceiling etc i/c cutting to size placing in position, welding to frame work i/c priming coat complete as per direction of Engineer in Charge. (Frame work to be paid separately) |
| 141 | Providing and fixing Table top Rectangular shape wash basin with 32 mm C.P.Brass Waste of standard pattern, fixed in RCC counter including cutting and making good the walls wherever required: White Vitreous China Table top Rectangular shape Wash Basin size 550x400 mm |
| 142 | Providing and fixing single lever Basin Mixer without popup waste system with 450 mm long braided hoses with extended nipple & spout including making good the walls where ever required all complete as per the architectural drawings & as directed by Engineer in charge. |
| 143 | Providing and fixing wall mixer 3-in-1 system with provision for overhead shower complete with 115 mm long bend pipe on upper side, connecting legs & Wall Flange including cutting & making good the walls where ever required all complete as per manufacturer's specifications & as per direction of Engineer in charge. |
| 144 | Providing and fixing Hand Shower (Health Faucet) (ABS Body) with 8mm Dia, 1 metre long Spirochrome flex tube & wall hook and fixing with required stainless steel screws etc all complete as per direction of Engineer in charge. |
| 145 | Providing and fixing stainless steel single towel rail 600 mm long without hangers complete as directed by Engineer in charge. |
| 146 | Providing and fixing towel ring square with round flange as directed by Engineer in charge. |
| 147 | Providing and fixing CP Sink Mixer with extended swinging spout (wall mounted ) with connecting legs and wall flanges including cutting & making good the walls where ever required all complete as per manufacturer's specifications & as per direction of Engineer in charge. |
| 148 | Providing and fixing Soap Dish Holder and fixing with required stainless steel screws etc all complete as per direction of Engineer in charge. |
| 149 | Providing and fixing Soap dispenser with glass bottle and fixing with required stainless steel screws etc all complete as per direction of Engineer in charge. |
| 150 | Providing and fixing CP Brass angle valve two in one of approved quality & as per direction of Engineer-in-charge. : 15 mm nominal bore |
| 151 | Providing and fixing Corner Glass Shelf with bracket complete as directed by Engineer in charge. |
| 152 | Providing and fixing on wall face unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 110 mm diameter. |
| 153 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 14735 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° with out door 110 mm diameter |
| 154 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 14735 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° with door 110 mm diameter |
| 155 | Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working pressure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make. The item is inclusive of the rate of rubber seal ring (working pressure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-in-charge.. Single tee with door 110 x 110 x 100 mm diameter |
| 156 | Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working pressure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-in-charge.. Single tee with out door 110 x 110 x 100 mm diameter |
| 157 | Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working pressure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make. The item is inclusive of the rate of rubber seal ring (working pressure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-in-charge.. Terminal guard / Vent Cowl 100 mm diameter |
| 158 | Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working pressure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make. The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-in-charge. Coupler 110 mm |
| 159 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC waste water vent pipes by means, screwed with M.S. screws of required length. complete.: 110 mm embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. |
| 160 | Providing and fixing on wall face unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 75 mm diameter. |
| 161 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 14735 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° with out door 75 mm diameter |
| 162 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 14735 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° with door 75 mm diameter |
| 163 | Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working pressure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make. The item is inclusive of the rate of rubber seal ring (working pressure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-in-charge.. Single tee with door 75 x 75 x 75 mm diameter |
| 164 | Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working pressure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-in-charge.. Single tee with out door 75 x 75 x 75 mm diameter |
| 165 | Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working pressure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make. The item is inclusive of the rate of rubber seal ring (working pressure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-in-charge.. Terminal guard / Vent Cowl 75 mm diameter |
| 166 | Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working pressure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make. The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-in-charge. Coupler 75 mm |
| 167 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC waste water vent pipes by means, screwed with M.S. screws of required length. complete.: 75 mm embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. |
| 168 | Providing and Fixing PVC Nahani trap of size 100mm of approved quality complete in all respect as per the direction of Engineer-In- Charge. |
| 169 | Providing and Fixing CP Grating in floor of size 100mm with or without centre hole of approved quality complete in all respect as per the direction of Engineer-In- Charge. |
| 170 | Supply, Installation, of Premium quality wooden((PINJAKARI) handmade jali crafted by highly skilled master craftsmen, featuring antique patterns with a modern touch. Made from solid wood such as teak, pine, rubber wood, or MDF (no PVC or fake wood), also available in acrylic and WPC options. Ideal for home décor, wall panels, partitions, and architectural interiors, inspired by traditional Kashmiri craftsmanship with intricate geometric and heritage designs. Durable, finely finished, and custom-made as per size requirements. complete in all respects |
| 171 | Providing and laying 12 mm thick AC-5 Grade grade laminate wooden flooring & Skirting of Action Tesa/ Greenply /Vista/Virgin or equivalent make and made having 0.2 mm thick direct laminate on top of specially developed substrate core (high density fibre board ) of plank size as per manufactures specification having smart lock , joint tongue and groove construction including top of skirting should be sealed with 4 mm thick teak wood lipping. The under layer has to be a 0.2 mm thick alkali resistant Polyethylene sheet of density 30-32 Kg per cum on top to secure the floor . The work should be carried out as per manufacture's installation procedure and as per direction of Engineer-in-charge |
| 172 | Proving and laying of hard stone soling of required profile with hammer dressed stones of required depth including preparing the bedding surface etc. all complete. |
| 173 | Providing and fixing Khatamband ceiling as per approved parts and i/c frame work with 2nd class badlo wood &12 mm thick commercial ply wood fixed with fevicol, nails etc. complete as per direction of Engineer-in-chargel |
| 174 | Supplying and Placing in Position of King Size Bed, Box Storage : (L) 2110mm X (W) 1960mm X (H) 1,100mm. The collection relives the charm of mid - century modern designs. Clean, linear styling in premium solid Teak wood finished in Walnut highlights the distinctive grains. An open framing of the headboard makes the bed look airy and light. Spacious box storage to keep your bedding essentials organized. Warp and scratch resistant solid beech wood assures durability. 12mm moisture -resistant plywood slats for superior support. Borer and Termite resistant plywood construction. Machine processed non -chipping and smooth finished edges makes safe for kids and pets. 3 -coat Melamine and 1 coat PU polish process to give a velvet touch assuring no colour fading even in the long run. King size dimensions (L) 2109mm X (W) 1956mm X (H) 1,093mm having 3 Year unmatched warranty for hassle -free service of Headboard & foot board made in combination of teak wood & commercial plywood. Boxes Made of commercial plywood. Internal part will be in raw finish & outer part will be in polish finish matching to other parts polish finish as per the direction of Engineer-in-charge including Supplying and Placing in Position of Bed side Table With dimensions top having 407mm x 407mm, height 508mm and drawer size 127mm With a playful contrast of refined finishes and clean lines,. The Acacia Dark and textured Greige finish adds a dimensional touch. Made with engineered wood wrapped in dark Acacia brown & cream -finished laminate. A drawer and spacious shelf combination offers abundant space for your bedtime essentials with Linear metal pull design. Smooth finished edges eliminate moisture seepage, prevent warping, and make it last longer. Premium 3 -coat Melamine and 1 coat PU High -quality polish with low chemical emission. 10mm high buffers offer ground clearance for easy cleaning. The product shall have warranty period of 3 years from the date of supply |
| 175 | Supplying and placing in position of Veneer 6 Seater Dining Set in Coffee Brown Size: (D) 2134mm X (W) 1069mm X (H) 762mm.Table Top Thickness 12mm toughened glass with edge mould. Dimension Of Chair (W) 432mm X (D) 483mm X (H) 1042mm. Seating Height 432mm. Inspired by clean lines of modern designs, our Havelock Collection features minimal silhouettes crafted with an eye for detail. The exotic veneer tabletop accentuates the distinctive wood grains. Paired with neatly tailored fabric dining chairs featuring padded backrests and elegant wooden accents. the Havelock is a timeless addition to any dining space. Includes: Rectangular dining table and six dining chairs. Tabletop crafted of exotic veneer. Legs crafted of premium solid wood. Kiln -dried solid wood makes it warp and scratch -resistant. Premium fabric upholstery feels soft and sumptuous. Breathable upholstery with a comfortable stretch, ideal for everyday use. Tilted padded backrest offer comfortable seating experience. Wooden accent on the chair complements the design. Soft cushioning dimensions 76.2mm back and bottom for offers comfortable seating experience. Comfortably seats up to six. The Teak wood furniture shall be finished with melamine 3 or more coat and 1 coat of PU which should be resistant to water, scratches, and heat. The product shall have warranty period of 3 years from the date of supply. |
| 176 | SUB-HEAD-I ( INTERNAL WIRING)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. : Group \\"C\\" |
| 177 | Note:- In areas where false ceiling are provided, termination of wires should be at the fittings. Metal Flexible conduits from ceiling junction box to the fittings shall be provided duly coupled at both ends. This shall be included within the scope of point wiring.) : Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 178 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. : 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 179 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. : 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 180 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. : 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 181 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. : 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 182 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. : 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 183 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. : 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 184 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. ; 3x1.5 sqmm |
| 185 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. : 6 x 1.5 sq. mm |
| 186 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. : 3x4 sqmm |
| 187 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. : 6x4 sqmm |
| 188 | Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. : 2 Pair |
| 189 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 190 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. : 20 mm |
| 191 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. : 25 mm |
| 192 | Supplying and fixing following sizes/ module, G I box along with modular base & cover plate for modular switches in recess etc. as required. : 1 or 2 Module |
| 193 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 194 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. : Telephone socket outlet |
| 195 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. : TV antenna socket outlet |
| 196 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. : Bell push |
| 197 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 198 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. : 1 or 2 Module (75mmX75mm) |
| 199 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 200 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required . |
| 201 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 202 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 203 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings) |
| 204 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 205 | Supplying and fixing following way, horizontal type TPN/SPN, sheet steel, MCB distribution board, 415/240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 4 way (4 + 12), Double door TPN MCBDB |
| 206 | Supplying and fixing following way, horizontal type TPN/SPN, sheet steel, MCB distribution board, 415/240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 6 way (4 + 18), Double door |
| 207 | Supplying and fixing following way, horizontal type TPN/SPN, sheet steel, MCB distribution board, 415/240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) :8 way (4 + 24), Double door TPN MCB DB |
| 208 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powderpainted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs(but without MCBsandincomer) as required. (Note: Vertical type MCB TPDBis normally usedwhere3 phaseoutlets are required.) : 4 way (4+24), Double door |
| 209 | Supplying and fixing 5 A to 63A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ; 5-32 Amps.SP MCB |
| 210 | Supplying and fixing 5 A to 63A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ; 40 Amps. TP MCB |
| 211 | Supplying and fixing 5 A to 63A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ; 63 Amps. TP MCB |
| 212 | Supplying and fixing 5 A to 63A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ; 40 Amps. TPN/ Four Pole MCB |
| 213 | Supplying and fixing 5 A to 63A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ; 63 Amps. TPN/ Four Pole MCB |
| 214 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. : 100 A, 16 KA,TP MCCB |
| 215 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. : 150A 16 KA,TP MCCB |
| 216 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. : 200 A, 16 KA,TPMCCB |
| 217 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. : 125 A, 16 KA, TP MCCB |
| 218 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. : 400 A, 35 KA TP MCCB |
| 219 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. : 40 A |
| 220 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. : 40 A |
| 221 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. : 1 run of cable |
| 222 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. : 12run of cable |
| 223 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 224 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. |
| 225 | Supplying, installation, testing and Commissioning of following ways Sub main Distribution Boards(SMBD's) factory fabricated from CRCA sheet ,surface / recess mounting, vertical type, 415 volts, Vertical panel Board System TPN MCCB distribution board of sheet steel, with MCCB input and MCCB output, dust protected, duly powder painted, insulated tinned cooper bus bar (400A),IP-41 or better , rated short circuit withstand capicity for busbar 25KA/36KA at 415V for 1Sec, common neutral link, earth bar, Suitable arrangement for mounting MCCB‟s, with provision of 400 amps TP 25 KA MCCB as incomer and 200A TP MCCB as outgoing, interconnection between incomer MCCB and bus bars (but without MCCB) , Incomer kit for 400A 3P MCCB and Key lock,confirming to IEC 60439(1) complete etc as required. : 4 way , upto 400A TP MCCB as incoming and 200 A TP MCCB as outgoing ( MCCB are not included in this item) |
| 226 | Supplying, installation, testing and Commissioning of following ways Sub main Distribution Boards(SMBD's) factory fabricated from CRCA sheet ,surface / recess mounting, vertical type, 415 volts, Vertical panel Board System TPN MCCB distribution board of sheet steel, with MCCB input and MCCB output, dust protected, duly powder painted, insulated tinned cooper bus bar (200A),IP-41 or better , rated short circuit withstand capicity for busbar 25KA/36KA at 415V for 1Sec, common neutral link, earth bar, Suitable arrangement for mounting MCCB‟s, with provision of 200 amps TP 25 KA MCCB as incomer and 125A TP MCCB as outgoing, interconnection between incomer MCCB and bus bars (but without MCCB) , Incomer kit for 200A 3P MCCB and Key lock,confirming to IEC 60439(1) complete etc as required. 4 way , upto 200A TP MCCB as incoming and 125 A TP MCCB as outgoing ( MCCB are not included in this item) : 4 way , upto 200A TP MCCB as incoming and 125 A TP MCCB as outgoing ( MCCB are not included in this item) |
| 227 | Supplying and fixing metering box with all following accessories for VTP SMDB's panel Board System ,MCCB incomer and MCCB outgoing i/c connections as per item no. 19 & 20 SH-I above suitable for 415 volts, complete etc as required as required : Ampere meter with selector switch : Volt Meter with selector switch ; R,Y, B phse indicator - 1 Set ; Metering Box : Ampere meter with selector switch 3Ph LED Ammeter Cl 0.5P ; Volt Meter with selector switch 3Ph LED Voltmeter Cl 0.5 (c) : R,Y, B phase indicator - 1 Set |
| 228 | SUB-HEAD-II ( FANs & FITTINGS)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). : Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) : 24-26 watt |
| 229 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). : Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) : 40 watt |
| 230 | SITC of 10 Watt or less, 5700/6500 K (2 Ft.) wall mounted LED batten mirror light fitting with aluminium heat sinkable provided for efficient heat dissipation complete with electronic driver, having minimum total system lumens ≥ 1100 etc. complete as reqd. |
| 231 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required : with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . : 18 watt |
| 232 | Providing and fixing 10 watt or less, 5700 K LED Bulk head luminaire made of die cast housing having system lumens ≥ 1000 at CRI ≥ 80, THD ≤ 10% and PF ≥ 0.90,Led life≥ 50,000Hrs, with IP66 protection and IK09 mounted directly on ceiling/ wall complete etc. as required. |
| 233 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) : 36 watt |
| 234 | Supplying and fixing of 25 Ltr capacity storage water heater having rating of 5 star and above glassline tank suitable for operation on 230V/50Hz and 2 KW heating element with protecting against over heating and dry heating, thermal cut out with LED indication light i/c installation on wall with das fastener water connections with reinforced rubber/plastic pipe 15 mm dia i/c testing, commissioning etc. as required at site. |
| 235 | Supplying and fixing of 70 Ltr capacity storage water heater having rating of min 3 star and above glassline tank/other suitable material, suitable for operation on 230V/50Hz and 3 KW heating element with protecting against over heating and dry heating, thermal cut out with LED indication light i/c installation on wall with das fastener water connections with reinforced rubber/plastic pipe 15 mm dia, 2 year product warrenty with 3 year on heating element i/c testing, commissioning etc. as required at site. |
| 236 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. Brush Less Direct Current (BLDC) Fan without Remote : 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 237 | Supplying, installation, testing & commissioning of 300 mm sweep metal ventilating exhaust fan complete with louver/ shutter, 1 phase , Air delivery minimum 1100 CMH, 900/1400 RPM with metal blade and frame duly powder coated, double ball bearing with heavy duty motor with protective bird gaurd including making good the damage, making connections with 3 X 1.5 sq. mm copper conductor PVC insulated and PVC sheathed round cable etc. as required. |
| 238 | Supplying, installation, testing and commissioning of 250 mm sweep min 1150 rpm vantilator fan with plastic louver and blade i/c connections with 13/0.20 mm twin core PVC sheathed flat flexible copper cable etc as required |
| 239 | SUBHEAD-III (LT PANEL, CABLE AND DWC PIPES)NOTE: The following provisions shall be required to be made in the switchboard detailed below:All live accessible parts shall be shrouded and all equipment shall be ginger touch proof. The busbar insulation shall be with heat shrinkable sleeves SMC / DMC shrouds and busbar supports shall be used. : Suitable tinned copper extension links for incoming / outgoing cables shall be provided wherever required. : Control circuits includes breaker control switch, auto manual selector switch, anti pumping relay, spring charging trip indication, Timer, Control wiring, Auxiliary contactors MCB's as required at site. : All fault level breaking capacity indicates shall be I.C.S. value at 415 volts. (ICS=ICU=ICW=100%) for 1 sec : MCCBs of current rating 250 Amps and above shall be provided with microprocessor based releases and those of 250 Amps below rating shall be provided with thermal magnetic releases. : All ACB/MCCB shall have with Rotary Handles. : Padlocking facility shall be provided on all outgoing feeders: All ACB's shall have all standard accessories such as CT,s Arc Chute, safety shutters etc. ; Link and drops from ACB / MCCB shall be designed for all rated current of ACB / MCCB rating at same amount of current density as of main busbar. : Compliance to the technical specifications of CPWD . : All MCCB in main panel should have O/L, S/C, E/F protection with S/C and E/F differtation. : Installation height of each panel should be min 400 from the ground level. ; All panel have Danger notice plate vitreous enamelled white on both sides and inscription in signal red colour of mild steel (200mm x 150 x 2mm thick) : Main & Distribution panel- Supplying, installation, testing & commissioning of cubical type floor mounted Main panel double door outdoor type with IP-54 rating having 400mm depth and suitable front face area suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for load bearing members and 1.6 mm thick for non load bearing members, 3 mm thick for gland plates i/c cleaning & surface treatment with 7 tank process before powder coating in approved shade, suitbale capacity extensible type TPN Aluminium Alloy bus bars with suitable rating Neutral of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35 MVA for I Sec. bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, having height 400mm above the ground level, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control cable etc. complete as reqd.The Panel shall have IP-54 rating . INCOMER- a) 1 No.800 A, Four Pole, 415V, 50 KA MCCB b) Digital flush type class -I accuracy multifunction meter showing V, A, PF, KVAR , KWH etc. with 3 Nos. current transformers of 1000/5 ratio, 15 VA Class 1.0 metering and class 5P10 for protection. c) 1 Set of three phase R,Y,B indicating lamps along with 2A SP MCB backup protection. d) Control 2A MCB, control terminals & wiring as required. e) Danger notice plate vitreous enamelled white on both sides and inscription in signal red colour of mild steel (200mm x 150 x 2mm thick) - 1 No. Bus Bar Electrolytic high conductivity aluminium TPN/ Four Pole busbars rated at 433V,50 Hz., 1000 amps of size 100x10mm, 36kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.Outgoings:- a) 315A 35 KA 3P MCCB - 3 Nos. b) 250A 35 KA 3P MCCB - 3 Nos. Main Non Essential Panel described as Above |
| 240 | Supplying, installation, testing & commissioning of cubical type floor mounted Main panel double door outdoor type with IP-54 rating having 400mm depth and suitable front face area suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for load bearing members and 1.6 mm thick for non load bearing members , 3 mm thick for gland plates i/c cleaning & surface treatment with 7 tank process before powder coating in approved shade, suitbale capacity extensible type TPN Aluminium Alloy bus bars with suitable rating Neutral of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35 MVA for I Sec. bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, having height 400mm above the ground level, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control cable etc. complete as reqd.The Panel shall have IP-54 rating . INCOMER a) 1 No400 A, Four Pole, 415V, 36 KA MCCB b) Digital flush type class -I accuracy multifunction meter showing V, A, PF, KVAR , KWH etc. with 3 Nos. current transformers of 600/5 ratio, 15 VA Class 1.0 metering and class 5P10 for protection. c) 1 Set of three phase R,Y,B indicating lamps along with 2A SP MCB backup protection. d) Control 2A MCB, control terminals & wiring as required.Bus BarElectrolytic high conductivity aluminium TPN/ Four Pole busbars rated at 433V,50 Hz., 600 amps of size 80x6mm, 36kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.Outgoings:-a) 200A 35 KA 3P MCCB - 6 Nos. Main Essential Panel described as Above |
| 241 | Supplying, installation, testing & commissioning of cubical type floor mounted Main panel double door outdoor type with IP-54 rating having 400mm depth and suitable front face area suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for load bearing members and 1.6 mm thick for non load bearing members , 3 mm thick for gland plates i/c cleaning & surface treatment with 7 tank process before powder coating in approved shade, suitbale capacity extensible type TPN Aluminium Alloy bus bars with suitable rating Neutral of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35 MVA for I Sec. bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, having height 400mm above the ground level, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control cable etc. complete as reqd.The Panel shall have IP-54 rating . INCOMER - a) 1 No 150 A, Four Pole, 415V, 25 KA MCCB b) Digital flush type class -I accuracy multifunction meter showing V, A, PF, KVAR , KWH etc. with 3 Nos. current transformers of 200/5 ratio, 15 VA Class 1.0 metering and class 5P10 for protection. c) 1 Set of three phase R,Y,B indicating lamps along with 2A SP MCB backup protection. d) Control 2A MCB, control terminals & wiring as required.Bus Bar - Electrolytic high conductivity aluminium TPN/ Four Pole busbars rated at 433V,50 Hz., 200 amps of size 30x5mm, 36kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.Outgoings:- a) 100A 16 KA TP MCCB - 6 Nos. Sub Distribution Essential/ Non Essential Panel describe as Above |
| 242 | Supplying, installation, testing & commissioning of cubical type floor mounted Main panel double door outdoor type with IP-54 rating having 400mm depth and suitable front face area suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for load bearing members and 1.6 mm thick for non load bearing members , 3 mm thick for gland plates i/c cleaning & surface treatment with 7 tank process before powder coating in approved shade, suitbale capacity extensible type TPN Aluminium Alloy bus bars with suitable rating Neutral of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35 MVA for I Sec. bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, having height 400mm above the ground level, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control cable etc. complete as reqd.The Panel shall have IP-54 rating . INCOMER- a) 1 No 150 A, Four Pole, 415V, 25 KA MCCB b) Digital flush type class -I accuracy multifunction meter showing V, A, PF, KVAR , KWH etc. with 3 Nos. current transformers of 200/5 ratio, 15 VA Class 1.0 metering and class 5P10 for protection. c) 1 Set of three phase R,Y,B indicating lamps along with 2A SP MCB backup protection. d) Control 2A MCB, control terminals & wiring as required.Bus Bar-Electrolytic high conductivity aluminium TPN/ Four Pole busbars rated at 433V,50 Hz., 200 amps of size 30x5mm, 36kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for jointsOutgoings:-a) 125A 16 KA TP MCCB - 4 Nos. Sub Distribution Lift panel describe as Above |
| 243 | Supplying, laying & fixing of following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade on surface/ in the existing RCC/ Hume/ Metel/ HDPE pipe/ or in recess or direct in ground etc. complete as reqd. : 3-½ x 185 Sq.mm. |
| 244 | Supplying, laying & fixing of following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade on surface/ in the existing RCC/ Hume/ Metel/ HDPE pipe/ or in recess or direct in ground etc. complete as reqd. : 3-½ x 95 Sq.mm. |
| 245 | Supplying, laying & fixing of following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade on surface/ in the existing RCC/ Hume/ Metel/ HDPE pipe/ or in recess or direct in ground etc. complete as reqd. : 3-½ x 70 Sq.mm. |
| 246 | Supplying, laying & fixing of following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade on surface/ in the existing RCC/ Hume/ Metel/ HDPE pipe/ or in recess or direct in ground etc. complete as reqd. : 4 x 25 Sq.mm. |
| 247 | Supplying, laying & fixing of following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade on surface/ in the existing RCC/ Hume/ Metel/ HDPE pipe/ or in recess or direct in ground etc. complete as reqd. : 3x50 sqm |
| 248 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 249 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ; 3-½ x 185 Sq.mm. |
| 250 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ; 3-½ x 95 Sq.mm. |
| 251 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ; 3-½ x 70 Sq.mm. |
| 252 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ; 4 x 25 Sq.mm. |
| 253 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ; 3 x 50 Sqm |
| 254 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. : 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 255 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. : 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 256 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. : 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 257 | SUB HEAD-IV ( STREET LIGHT POLES & Fitting)-Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 35 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%),, Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) Charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, with Lithium-Iron Phosphate Battery (LiFePO4), charging time 8-10 hours, Battery backup time 12 hours (minimum), LED fixture watt 35 watt, Input voltage: 12V DC , Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI >70 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPR 15 , lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K (As per American National Standard Institute (ANSI Bin)), life time (LED, Driver & electrical circuitry) of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic switch on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). : 35 Watt (System lumen efficacy >120 lm/Watt) |
| 258 | SITC of 6 Mtr. height street light pole made out of Galvanised Mild steel tabular/ Conical/ Octangual having min140mm dia at bottom and 75 mm dia at Top. The Poles are primer coated and painted with Polyurethane paint. Having one way arm for fitting installation.The Poles has a service window at the bottom comprising four way 25Amp connector terminal and a MCB. Poles has a mild steel base plate 300 mm x 300 mm having four numbers mounting holes and can be mounted with four numbers anchor bolts suitable Cement Concrete foundation of size not less than 0.50 mtr x 0.50 mtr x 1.0 mtrs. with 1:3:6 CC (1 cement:3 coarse sand :6 graded stone aggregate 20 mm nominal size), 4 Nos hot dip glavanized L-type Anchor bolts of minimum 20 mm dia x 600mm long including providing 40mm dia DWC pipe sleeve 1.00 mtr. length in the CC foundation for cable entry, plastering the same with fine sand and having horizontal top surface without any slope including two coats of exterior paint complete as required. |
| 259 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).powder coated pressure die cast aluminium body. : 45 watt |
| 260 | Supplying, installation, testing and commissioning of outdoor double door floor mounted modular, sectionalised, compartmentalized type MV cubical panel of suitable size fabricated from CRCA sheet steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having canopy for rain water protection, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with aluminium bus DMC/SMC busbar supports, suitable for 3 phase 415 V 50 HZ AC supply i/c providing and fixing the following switchgear & accessories etc. mounted thereon complete with gaskets and solid copper connections & interconnections as per specifications complete as required. The panel shall be supplied with suitable pedestal of angle iron (The Panel shall have IP-54 rating.) INCOMING a) 125 Amp FP thermal magnetic based MCCB 25 KA:- 1No. b) 4 strip 200 Amp aluminium bus bar :- 1setOUTGOING a) 40 A SPN/TPN MCB 10 KA:- 6 Nos. b) Digital Timer and contactor of suitable capacity for ON/OFF external lighting along with indicators. c) Digital Voltmeter 0-500V. d) LED Type Phase Indicating lamp For RYB -1 Set e) 25 mm x 5mm copper earth bus through out the width of panel with suitable drilled holes etc. f) Danger notice plate vitreous enamelled white on both sides and inscription in signal red colour of mild steel (200mm x 150 x 2mm thick) - 1 No.Street light Feeder Pillar describe as above |
| 261 | Supplying, laying & fixing of following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade on surface/ in the existing RCC/ Hume/ Metel/ HDPE pipe/ or in recess etc. complete as reqd. : 3x 10 sq. mm. |
| 262 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 263 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. : 3x 10 sq. mm. |
| 264 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. : 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 265 | Earthing With GI pipe 4.5m long X 40mm dia i/c accessories and providing masonary encloure with cover palte having locking arrangement etc with charcoal or coke and salt complete etc as reqd. |
| 266 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required |
| 267 | Pdg. & Fixing 25mm X 5mm GI strip on surface or in recess for connection etc. as reqd. |
| 268 | SUB HEAD -V FIRE FIGHTING SYSTEM - Pumping Equipments(a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Terrace) (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal footmounted type with Class-'F' insulation, conforming to IS-12615: 2018. (d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered with anti vibration pads. : 450 lpm at 35 m Head |
| 269 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia |
| 270 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
| 271 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia |
| 272 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 100 mm dia |
| 273 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 274 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia |
| 275 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. : 100 mm dia |
| 276 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) |
| 277 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. : (a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 (b) 20 mm nominal internal dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipmets on wall. (d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. : 30 m |
| 278 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) |
| 279 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe |
| 280 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 281 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 282 | Fabrication, Supplying, installation, testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm. Thick CRCA sheet, having IP-42 degree of protection compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade, cable alley, inter-connection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply for outdoor application as required. (For 1W +1S Pump) Number of pumps - 2 Incomer- 63 Amp. 10 KA TP&N MCB - 1 No.Digital Voltmeter (0-500 Volts) with selector swtich - 1 No.Digital Ammeter (0-60Amp. ) with selector swtich & CTs etc. - 2 SetSet of 3 Phase indicating Lamp - 1 SetSet of Al. bus bar 100 Amp. - 1 SetSingle Phase Preventor - 2 Nos. Outgoing :- 40 Amp. 10 KA TP&N MCB - 2 Nos.Fully automatic DOL starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation of 10 HP pump motor set - 2Nos.Selector switch for selection of pump for operation out of two pumps, local/ remote, auto/ manual/ off operation ON/OFF indication lamps with individual Toggle switch, Pump ON/OFF indication, Control MCB etc.Providing & wiring for connection of the pressure switch and auto operation including provision of remote switch cable connection etc as reqd. 3 phase indication LED Lamp - 1 set |
| 283 | SUB-HEAD-VI (EARTHING &LIGHTING)Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealedmaintenance free batteries with automatic charger.The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. : Two Loop |
| 284 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 285 | Supplying, installation, testing & commissioning of addressable manual call point complete as required |
| 286 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 287 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 288 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 289 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. and laying on surface, ceiling/wall with saddle /laying in exisiting conduit/chanell/tray complete etc as required. |
| 290 | PA system to be integrated with Fire alarm Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 291 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 292 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. For speakers etc |
| 293 | Safety Signages and Fire Extinguisher -Providing and fixing Architectural hanging/ wall mounted Signage system direct fixed on wall / ceiling comprising of 2mm aluminuim PHOTOLUMINESCENT SAFETY SIGNAGES high intensity luminous properties with Ultra Violet Protection Layer butcontains no lead or phosphorus etc i/c Printed graphics symbols & written message in English & bilingual fixed with fastner/ steel screw complete etc. as reqd. |
| 294 | SITC of maintained LED slim Exit/Egress Lights with self contained maintenance free nickel cadmium rechargabe battery pack , upto 2 hrs battery backup, power consumption less than 5Watt. constituted with aluminium housing body wall/ceiling mounted with. Installed with 02 nos suitable type suspension. equipped withPush test switch and indicator . RED LED indicates charging . Input 230V , 50Hz . 16 - 24 Hrs. Recharging Period Constant Current Charger. All facia on clear acrylic and thickness of acrylic not less than 8 mm. Dimensions 300mm x 180mm etc. as required.(Double sided). |
| 295 | SITC of 6 kg ABC Powder (Mono-Ammonium Phosphate IS 15683:2006 Marked, Powder Stored Pressure Type Portable Fire Extinguisher Complete in all Respect with IS 14609 marked, MAP90, with wall mounting bracket. complete etc as required. |
| 296 | SITC of Fire Extinguisher CO2 Type,4.5 Kg complete with ISI Marked Steel Body & ISI Marked Valve Duly filled & complete Conforming to IS:15683, with wall mounting bracket. complete etc as required. |
| 297 | SUB-HEAD-VII (EARTHING &LIGHTING) -Earthing With GI pipe 4.5m long X 40mm dia i/c accessories and providing masonary encloure with cover palte having locking arrangement etc with charcoal or coke and salt complete etc as reqd. |
| 298 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required |
| 299 | Pdg. & Fixing 25mm X 5mm GI strip on surface or in recess for connection etc. as reqd. |
| 300 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 301 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 302 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 303 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 304 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. |
| 305 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 306 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 307 | SUB-HEAD- VIII ( Lifts) - 6 passanger (480 Kg)Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (PartIII Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:- (i) Speed-1 MPS (ii) Floors-3 (G+2) (iii) Travel -14 Meters (approx.) (iv) Stops & opening- 3 stops and 3 openings (v) Controller: A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. vii) Operation: Microprocessor based single automatic push button/ simplex selective collective/duplex collective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/ Honeycomb / Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors (a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). (b) Landing doors: stainless steel scratch proof .(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided : 6 passanger (480 Kg) |
| 308 | UNITARY SYSTEM -Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). : Inverter Type - Hot & Cold : 1.5 TR with 3 Star BEE Rating Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail