| 1 | Maintenance of Re-circulatory type Air Handling Units (AHU) as per clause no. 1 of tender specifications. |
| 2 | Recirculatory AHU from 2000cfm to 8000cfm (Qty. 18 Nos) |
| 3 | Recirculatory AHU from 10000cfm to 20000cfm (Qty. 13 Nos) |
| 4 | Maintenance of Once-through type Air Handling Units (AHU) as per clause no. 2 of tender specifications. |
| 5 | Once-through AHU from 3000cfm to 8000cfm (Qty. 9 Nos) |
| 6 | Once-through AHU from 10000cfm to 12000cfm (Qty. 6 Nos) |
| 7 | Maintenance of ventilation blowers from 21,000 cfm to 39,000 cfm at 50 mm WC static pressure as per clause no. 3 of tender specifications (Qty. 13 Nos). |
| 8 | Maintenance of following FRP fume hood exhaust systems on ML terrace, as per clause no. 4 of tender specifications. |
| 9 | FRP fume hood exhaust systems of 3000 cfm (Qty. 17 Nos). |
| 10 | FRP fume hood exhaust systems of 6000 cfm (Qty. 14 Nos). |
| 11 | Maintenance of centrifugal chilled water pumps as per clause no. 5 of tender specifications. |
| 12 | Chilled Water booster pump from 100 to 350 gpm and 20m head, at AH, Sp.Area & L&PTD basement (Qty. 5 Nos.). |
| 13 | Chilled Water booster pump of 500 gpm and 20m head, at B-144 & canteen basement (Qty. 4 Nos.). |
| 14 | Chilled Water booster pump of 1500 gpm and 25m head, running on VFD at basement pump rooms (Qty. 8Nos.). |
| 15 | Maintenance of centrifugal sewage pumps as per clause no. 6 of tender specifications. |
| 16 | Submersible pumpset, 2HP, 3-Phase at A & D Block dry pit. (Qty. 2 No). |
| 17 | Sewage Pumpset, 5HP, 3-Phase at 'A' & 'D'-Block basement (Qty. 4 Nos.). |
| 18 | Submersible pumpset, 10HP, 3-Phase at A & D Block wet pit. (Qty. 2 No). |
| 19 | Up keeping and annual testing of de-watering submersible pump, 5HP, 3-Phase, ML basement as per clause no. 7 of tender specifications(Qty. 5 Nos). |
| 20 | Maintenance of following facilities at ICCM as per clause no. 8 of tender specifications. |
| 21 | Fan housing unit of 1000cfm at 240 mm WC. (Qty. 2 Nos). |
| 22 | Cooling coil housing unit, once through type for 1000 cfm, 10TR (Qty. 1 No.) |
| 23 | Exhaust blower of 1000 cfm at 100 mm WC (1 No.). |
| 24 | Comprehensive Maintenance of Tower AC of 4.0 TR capacity, DX type, air cooled (Qty. 2 Nos). |
| 25 | Comprehensive Maintenance of Precision package AC unit of 5.71 TR capacity, DX type, air cooled (Qty. 2 Nos). |
| 26 | Comprehensive Maintenance of Package DX AC units, water cooled condenser, complete accessories for 2-99-H as per clause no. 9 of tender specification. |
| 27 | Packaged DX AC unit each 16.5TR capacity (Qty. 4 No) |
| 28 | Cooling tower, 40TR capacity each with pumps for above 16.5TR Package DX AC units (Qty. 2 No) |
| 29 | Comprehensive Maintenance of Package DX unit of 8.5TR, air cooled condenser with accessories in room no. G-118-S as per clause no. 10 of tender specification (Qty. 2 No). |
| 30 | Maintenance of Inline Ventilation blowers from 1000 cfm to 2000 cfm, as per clause no. 11 of tender specification (Qty. 15 Nos). |
| 31 | Cleaning of grease filters, 36 nos, installed at kitchen fume hood exhaust system of ModLab Canteen, Basement as per clause no. 12 of tender specification. |
| 32 | Cleaning of sump (Vol. approx. 15 Cu.M each) in pump rooms at Basement of modlabs as per clause no. 13 of tender specification. (Qty. 4 Nos sump). |
| 33 | Maintenance of 150mm dia Strainers as per clause no. 14 of tender specifications. (Qty. 18 Nos). |
| 34 | Operation and maintenance of chilled water line manually operated valves as per clause no. 15 of tender specification. |
| 35 | NB Size: 80 mm to 150 mm. |
| 36 | NB Size: 200 mm to 300 mm. |
| 37 | Overhauling of following breakdown equipments, as per clause no. 16 of tender specification. |
| 38 | Overhauling of breakdown de-watering submersible pumpset from 200 lpm to 600 lpm and 20Mtr head. |
| 39 | Overhauling of breakdown motors upto 2 HP, as per tender specification. |
| 40 | Replacement, Supply & installation of V-Belts during contract period as per clause no. 17 of tender specification. |
| 41 | Replacement, Supply & installation of V-Belts during contract period as per clause no. 18 of tender specification. |
| 42 | Replacement, Supply & installation of V-Belts during contract period as per clause no. 19 of tender specification. |
| 43 | Replacement, Supply & installation of V-Belts during contract period as per clause no. 20 of tender specification. |
| 44 | Replacement, Supply & installation of V-Belts during contract period as per clause no. 21 of tender specification. |
| 45 | Replacement, Supply & installation of following bearings during AMC at site as per clause no. 22 of tender specification. |
| 46 | A205F (SA205) |
| 47 | FSB P205 |
| 48 | FYH SA 205 with eccentric locking collar & rubber sitting ring : 63mm OD & 21.5 mm Width. |
| 49 | FYH SA 206 with eccentric locking collar & rubber sitting ring : 72mm OD & 23mm Width. |
| 50 | FYH UK 207 without housing but with Adapter sleeve & Rubber Sitting ring : 80mm OD & 24 mm Width. |
| 51 | FYH UK 208 without housing but with Adapter sleeve & Rubber sitting ring : 84mm OD & 27mm Width. |
| 52 | FYH UK 209 without housing but with Adapter sleeve & Rubber sitting ring : 94mm OD & 28 mm Width. |
| 53 | FYH UK 210 without housing but with Adapter sleeve & Rubber Sitting ring : 100mm OD & 30 mm Width. |
| 54 | FYH UK 211 without housing but with Adapter sleeve & Rubber sitting ring. |
| 55 | Replacement, Supply & installation of following bearings during AMC at site as per clause no. 23 of tender specification. |
| 56 | FYH 213 Pillow Block with grease nipple, Self aligning bearing, UK 213 with adapter sleeve. Blower Shaft Dia 60 mm |
| 57 | Housing No. FYH F208 & Bearing No. NA208FYH and Eccentric locking collar No. A208-24F |
| 58 | Housing No. FYH P206, Bearing No. NA206FYH and Eccentric locking collar No. A206-19F |
| 59 | Housing No. NTN P205J, Bearing No. NTN UL 205-100 GY Eccentric locking collar. |
| 60 | KTN9-1306 bearing for ICCM |
| 61 | SKF 1310 EKTN9 With adapter sleeve suitable for equipment. |
| 62 | SKF 2211 EKTN9/C3 |
| 63 | SKF 22209 EK with adapter sleeve. |
| 64 | SKF 22210 EK with adapter sleeve. |
| 65 | Replacement, Supply & installation of following bearings during AMC at site as per clause no. 24 of tender specification. |
| 66 | SKF 22211 EK with adapter sleeve. |
| 67 | SKF 22315 EK Roller Bearing with adapter sleeve suitable for equipment. |
| 68 | SKF 6206 with brass shaft sleeve. |
| 69 | SKF 6304 ZZ |
| 70 | SKF 6305 |
| 71 | SKF 6306 with brass shaft sleeve. |
| 72 | SKF 6309/C3 |
| 73 | Replacement, Supply, installation of old deteriorated SS hardware, as per clause no. 25 of tender specification. |
| 74 | SS Nut bolt with washer M10 X 50mm. |
| 75 | SS Nut bolt with washer M12 X 60mm. |
| 76 | SS Nut bolt with washer M12 X 100mm. |
| 77 | SS Nut bolt with washer M16 X 120mm. |
| 78 | SS Nut bolt with washer M16 X 150mm. |
| 79 | SS Nut bolt with washer M18 X 150mm. |
| 80 | Replacement, Supply, installation of old deteriorated SS, T-slot hardware, as per clause no. 26 of tender specification. |
| 81 | SS T Slot bolt, nut with washer M12 X 150mm. |
| 82 | SS T Slot bolt, nut with washer M16 X 150mm. |
| 83 | SS T Slot bolt, nut with washer M20 X 150mm. |
| 84 | SS T Slot bolt, nut with washer M20 X 200mm. |
| 85 | Replacement, Supply & installation of following Pulleys with key & suitable belt, 2B, Dual Duty Taper-Lock, Cast Iron, as per clause no. 27 of tender specifications. |
| 86 | Pulley, PCD upto 155 mm |
| 87 | Pulley, PCD from 160 mm to 250mm |
| 88 | Replacement and SIT of Temperature gauges, dial type with accessories, as per clause no. 28 of tender specifications. |
| 89 | Replacement and SIT of Pressure gauges, dial type with accessories, as per clause no. 29 of tender specifications. |
| 90 | Replacement/ Supply and installation of complete assembly of Spring Isolators, as per clause no. 30 of tender specification. |
| 91 | Replacement, supply & installation of Linear grille with VCD, extruded aluminium, as per clause no. 31 of tender specification. |
| 92 | Replacement, supply, fabrication and installation of Diffuser with VCD, extruded aluminium, as per clause no. 32 of tender specification. |
| 93 | Replacement, supply & installation of Damper, GI construction, multi louvers opposed blade type, manually operated, as per clause no. 33 of tender specification. |
| 94 | Replacement, supply & installation of Damper, FRP construction, manually operated, as per clause no. 34 of tender specification. |
| 95 | Replacement, supply & installation of Air Filters, 4 ply pleated HDPE washable type, 50 mm deep in aluminium casing, as per clause no. 35 of tender specification. |
| 96 | Replacement, Supply, fabrication and installation of GI ducting and sheet metal spares made out of 1.0 mm thick GI sheet, as per clause no. 36 of tender specification. |
| 97 | Replacement, Supply, fabrication and installation of FRP ducting and components, 6.0 mm thickness, as per clause no. 37 of tender specification. |
| 98 | Supply, installation and testing of following instruments and equipments, as per clause no. 38 of tender specification. |
| 99 | Sound level (dB) meter, Range 35dB to 130dB. |
| 100 | Digital Anemometer, Air velocity range from 0 to 50 Meter/sec. |
| 101 | Hand-Held Mechanical Tachometer, 30-50,000 rpm with accessories. |
| 102 | Hand-Held Digital Tachometer, 30-50,000 rpm with accessories. |
| 103 | Belt Tension Meter, analog type |
| 104 | Belt Tension Meter, digital type |
| 105 | Supply, installation and testing of following tools /instruments as per clause no. 39 of tender specification. |
| 106 | Puller for manually removal of pulley and bearing, Heavy-Duty Adjustable 2-Leg Puller Tool. Range : 40mm to 75mm, 65mm thickness. |
| 107 | Puller for manually removal of pulley and bearing, Heavy-Duty Adjustable 3-Leg Puller Tool. Range : 70mm to 100mm, 75mm thickness. |
| 108 | Puller for manually removal of pulley and bearing, Heavy-Duty Adjustable 3-Leg Puller Tool. Range: 100 mm to 300 mm dia. |
| 109 | Hot Air Blower, Duel Speed, 2000Watts, 3 Mtr Cable, SS Accessories. |
| 110 | Industrial vacuum cleaner, storage tank stainless Steel body, In hand Suction control, Large capacity of 12 Litre for Wet & Dry, 1500Watt, 5Mtr power cable. |
| 111 | Replacement, Supply, installation and testing of new monoblock pumpset, 350 gpm, 25m head, 7.5kW, 3-phase, for L&PTD A-Block basement, as per clause no. 40 of tender specification. |
| 112 | Replacement, Supply, installation and testing of new centrifugal pumpset, 375gpm and 15m head, split casing type, with mechanical seal, Pin-Bush type coupling, motor, for B-144, as per clause no. 41 of tender specification. |
| 113 | Replacement, Supply, installation and testing of new Sewage submersible pumpset with starter, 10 HP, SS construction, as per clause no. 42 of tender specification. |
| 114 | Replacement and SIT of sprinkler assembly set for cooling tower, induced draft, 40TR capacity each. Please refer Clause no. 43 of tender specifications for detailed scope of work. |
| 115 | Replacement, Supply and installation of new Pin-Bush type CI Coupling set for pumps having 1500gpm, 50HP capacity, as per clause no. 44 of tender specification. |
| 116 | Replacement, supply, installation & testing of electrical operated fire damper for G-130-S AHU, as per clause no. 45 of tender specification. |
| 117 | Supply, installation & testing of Ball Valve, DN15 (1/2\\"), SS material, two piece, flanged end, class#300, along with fittings for LPG gas manifold system as per clause no. 46 of tender specification. |
| 118 | Replacement, Supply, installation and testing of Pot Strainer, 100 mm dia size, Carbon steel body, flanged end, SS filter element, as per clause no. 47 of tender specification. |
| 119 | Replacement and Supply, installation and testing of Air Release Valve assembly, 40 mm dia size, CI body, flanged end, as per clause no. 48 of tender specification. |
| 120 | Replacement and Supply, installation and testing of Globe Valve, SS body, flanged end, as per clause no. 49 of tender specification. |
| 121 | Globe Valve, SS body, 50 mm dia size |
| 122 | Globe Valve, SS body, 80 mm dia size |
| 123 | Globe Valve, SS body, 100 mm dia size |
| 124 | Supply and installation of GI Piping, ERW, heavy class, upto 150mm NB, including necessary fittings and accessories as per clause no. 50 of tender specifications. |
| 125 | Removal and disposal of old piping along with accessories, etc, as per clause no. 51 of tender specifications. |
| 126 | Repairing by only welding of pipes and structural material complete with final run at site as per clause no. 52 of tender specification. |
| 127 | Removal and disposal of old unwanted metallic ducting along with accessories as per clause no. 53 of tender specification. |
| 128 | Removal and disposal of old unwanted FRP ducting along with accessories as per clause no. 54 of tender specification. |
| 129 | Replacement, Supply and installation of Nitrile Rubber thermal insulation, 19mm thick, Class-O, close cell as per clause no. 55 of tender specification. |
| 130 | Replacement, repair and Supply and installation of Thermocole Insulation, 50mm Thick, TF quality with sand cement plastering etc. as per clause no. 56 of tender specification. |
| 131 | Replacement, Supply and installation of Acoustic Insulation, nitrile rubber, open cell, 50 mm thickness, in plant room with framing etc. as per clause no. 57 of tender specification. |
| 132 | Replacement, Supply and installation of Aluminium cladding, 0.6 mm thick sheet, fastened suitably etc. as per clause no. 58 of tender specification. |
| 133 | Supply, fabrication and installation of MS supports as per clause no. 59 of tender specification. |
| 134 | Removal and disposal of old deteriorated MS supports as per clause no. 60 of tender specification. |
| 135 | Supply, fabrication and installation of SS supports and other accessories as per clause no. 61 of tender specification. |
| 136 | Replacement, Supply and installation of Stainless Steel Crimped Wire Mesh made out of 3 mm dia wire with 15 mm square grid, at various locations as per clause no. 62 of tender specification. |
| 137 | Repair, Replacement of PCC construction work at various locations as per clause no. 63 of tender specification. |
| 138 | Painting on surface after proper scraping, cleaning at site, as per clause no. 64 of tender specification. |
| 139 | Painting of metallic surface. |
| 140 | Painting of cement plaster surface. Please Enable Macros to View BoQ information |