|
| 1 | B-44/1.8 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | B-54/3.1.6 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 3 | B-59 /4.1 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 4 | B-62 /4.13.2 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 5 | B-61 /4.9 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 6 | S-27/3.44.2 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110 mm dia |
| 7 | S-28/3.45.4 (ii) Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend 87.5 Dg 110mm dia |
| 8 | B-3.1.5 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). |
| 9 | B-293 Supply of Stone Aggrigate (Single Size) atQuarry 40 mm size , |
| 10 | B-G.4.2/C-.13/C-4 Carriage of Stone Aggregate Upto 80 Km |
| 11 | B-43/1.1 Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed : All kinds of soil |
| 12 | B-9.1 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 13 | B-6.1.6 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: |
| 14 | B-11.3.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm thick nominal size aggregate. |
| 15 | B-12.3.2 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm Thick |
| 16 | G 4.1 Carriage of Earth, Sand, Lime, Morrum manure or sludge lead 5 KM |
| 17 | B-1.25 Filling available excavated earth (excluding rock) intrenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 18 | Labour charge for spreading of 20-63 mm nominal size Hand / Crusher broken stone agregate in unifor layer of 100 mm thicknessin yardof any substation (charged / uncharged) GSS by manual / mechanical means, as permitted by the Engineer In Charge with due care as per safety norms of substation complete in all respect with all lead & lift.( Item Rate approved by CE civil ) |
| 19 | Providing and fixing 30mm thick ferrow cast RCC cable trenche cover upto a span of 1200mm c.c. grade M-25 with all left and lift complete having outer frame of M.S. flate 30x3mm and reinforcement consisting of 6mm dia MS round bars both way at the specing of 10cm C/C weleded with outer frame and two layers of G.I. wire 12mm hexagonl shape of 24gauge including concrete additional admixture like plasticiser both impervingcompound etc. manufacturing with vibro pressing system 20% covers have lifting hooks as per design and exposed surface of M.S flates/hooks shall be painted with two coats of superior quality corrosion resistance paint, cover shall be adiquate to take a miminum live load of 2000 Kg. per sqm/minimumultimate load of 3000 Kg. per sqm.( Item Rate approved by CE civil ) Please Enable Macros to View BoQ information |