| 1 | Providing and Filling Construction and Longitudinal joints (6 mm wide x 65 mm deep) in VDC/PQC M- 30 by groove cutting machine, providing and filling joints with Polysulphide Pour Grade sealent of approved make in the VDC M-30 complete as per specifications and directions of Engineer-incharge. (Item of dowel bars / tie bars to be paid separately). |
| 2 | Earth Filling under floors with Tibba sand taken from outside the campus area with all lead and lift, including loading, unloading, laid in 25 cm layers including compaction upto 98% of SPD , watering compensation of earth etc. complete in all respect with entire satisfaction of Engineer in Charge. (N.S.ITEM) Note : Density to be checked layer wise and recored in register. |
| 3 | Extra for kota stone flooring in treads of steps and risers using single length up to 2.00 metre. |
| 4 | Providing and fixing of GI chain link fabric fencing of required with of mess size 50x50 mm including strengthening with 2 mm dia of wire or nuts ,bolts and washers as required complete as per the Engineer-in-charge -made of GI wire of dia. 4 mm |
| 5 | Providing and fixing heavy Duty S.S Handle bolt (200 long) with nuts and screws etc complete (N.S.ITEM) (Grade 304) |
| 6 | Providing and fixing heavy Duty S.S tower bolt (18` long) with nuts and screws etc complete (N.S.ITEM) (Grade 304) |
| 7 | Providing and fixing Heavy Duty. S.S tower bolt (6` long) with nuts and screws etc complete (N.S.ITEM) (Grade 304) |
| 8 | Providing and fixing Heavy Duty S.S Sliding bolt (200mm x16 mm dia.) with nuts and screws etc complete (N.S.ITEM) (Grade 304) |
| 9 | Supply of Door handle size 32mmx457mm H-type (CTC 308mm) to required colour or shade, with necessary SS screws and Nut etc. complete :- (make:- OZONE , Dorma) |
| 10 | Supply of Patch Lock to required colour or shade, with necessary SS screws and Nut etc. complete :- (make:- OZONE , Dorma) |
| 11 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Door Tees :- 110mmx110mmx110 mm |
| 12 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Plain Tee 160 mm |
| 13 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- door bend 87.5 degree 110 mm |
| 14 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Door bend 87.5 degree 160 mm |
| 15 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-plain bend 40 mm |
| 16 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Plain bend 50 mm |
| 17 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Plain bend 110 mm |
| 18 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Plain bend 160 mm |
| 19 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Plain Tee 110 mm |
| 20 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-plain Y 90mmx90 mmx90 mm |
| 21 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Plain Y junction 110mm x110mmx110mm |
| 22 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Door Y junction 110x110x110 mm |
| 23 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Double Y junction 110x110x110x110 mm |
| 24 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Y junction 160 mm |
| 25 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Double Y Junction 160x160x160x160 mm |
| 26 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-coupler 40 mm |
| 27 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Coupler 50mm |
| 28 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-coupler 90 mm |
| 29 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Coupler 110 mm |
| 30 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Coupler 160 mm |
| 31 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- bend 45 degree 40 mm |
| 32 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- bend 45 degree 50mm |
| 33 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- bend 45 degree 90mm |
| 34 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- bend 45 degree 110 mm |
| 35 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- bend 45 degree 160 mm |
| 36 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- bush 160mm x110 mm |
| 37 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Bush 110x90 mm |
| 38 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM) -Bush 50x40 mm |
| 39 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- End cap 110 mm |
| 40 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-End cap 160mm |
| 41 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- door end cap 110 mm |
| 42 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- door end cap 160 mm |
| 43 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Cowl 90 mm |
| 44 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-Cowl 110 mm |
| 45 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Cowl 160 mm |
| 46 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- P trap 110x110 mm |
| 47 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)-S trap 110x110 mm |
| 48 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Gully trap 150x150x150 mm |
| 49 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- 50 mm dia pipe UPVC |
| 50 | Providing and fixing for SWR Pipes/as per site required used pipes conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge (N.S ITEM)- Floor drain jali (S.S) |
| 51 | Providing and fixing Baloon/chilly Clamp 2 to 2.5mm pati thickness with 8mm dia bullet fastner, 8mm tie rod witth Nut and washer for pipe hanging 25mm to 80mmDia |
| 52 | Providing and fixing Baloon/chilly Clamp 2 to 2.5mm pati thickness with 10mm dia bullet fastner, 10mm tie rod witth Nut and washer for pipe hanging for 90mm to 110mm Dia pipe |
| 53 | Providing and fixing Baloon/chilly Clamp 2 to 2.5mm pati thickness with 10mm dia bullet fastner, 10mm tie rod witth Nut and washer for pipe hanging for 150mm to 200mm dia pipe |
| 54 | Providing and fixing Hand shower (Health faucet) with 1.0m long easy flex tube in chrome finish and wall hook of jaquar, Grohe, Kohler make. with all accessories complete with all respects (N.S ITEM) |
| 55 | Providing and fixing of straight Grab bar 300 mm long stainless steel. |
| 56 | Providing and fixing of U grab bar stainless steel. |
| 57 | Providing and fixing of 50 mm Dia MS Threaded Coupler |
| 58 | Providing and fixing of CPVC Brass MTA 20x15 mm |
| 59 | Providing and fixing of CPVC Brass MTA 50x50 mm |
| 60 | Providing and fixing of CPVC Brass MTA 65x65 mm |
| 61 | Providing and fixing of Limit switch for pump |
| 62 | Providing and fixing of CPVC ball valve 20 mm dia. |
| 63 | Providing and fixing of cpvc ball valve 25 mm dia |
| 64 | Providing and fixing of cpvc ball valve 50 mm dia |
| 65 | Providing and fixing of cpvc union 25 mm dia |
| 66 | Providing and fixing of cpvc union 32 mm dia |
| 67 | Providing and fixing of cpvc union 40 mm dia |
| 68 | Providing and fixing of cpvc union 50 mm dia. |
| 69 | Providing and fixing of cpvc union 75 mm dia |
| 70 | Providing and fixing of cpvc union 100 mm dia |
| 71 | Providing and fixing of 200 mm Dia UPVC Pipe quick fix Type B/6Kg/Cm2 Pressure for Sewer and Strom Water Line |
| 72 | Supplying, installation, testing and commissioning of intelligent addressable programmable sounder complete as required. |
| 73 | Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required. |
| 74 | Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required. |
| 75 | Supplying, installation, testing and commissioning of addressable manual call point complete as required. |
| 76 | Supplying, installation, testing and commissioning of addressable fire control module complete as required. |
| 77 | Supplying, installation, testing and commissioning of addressable phone control module complete as required. |
| 78 | Supplying, installation, testing and commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. |
| 79 | Supplying, installation, testing and commissioning of fire fighter phone jack complete as required. |
| 80 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. TEN LOOP PANEL |
| 81 | Supplying, installation, testing and commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required |
| 82 | Supplying, installation, testing and commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 83 | Supplying and laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring and LSZH outer sheath complete as required. fire cable |
| 84 | Supply,installation,testing and commissioning of two pole structure with required arrangement for terminating 11KV overhead conductor on one side and 11KV, 1R x 3 x 300 sq.mm. Al conductor XLPE cable on the other side including providing triple pole ,mechanically operated mounted on insulators and steel frame with operating mechanism worked from ground level,expulsion fuses of 33KV ,required rating along with 11KV 200 amp air break isolator suitable for outdoor application ,earth switch, Metal oxide type Lightning arrester complete with all fittings and discharge capacity 50 KA complete as required. |
| 85 | Supplying / Receiving, Installation, Testing and Commissioning of Powder coated, 14 SWG CRCA sheet steel enclosed 11KV H.T. Metering Panel complete with the following:1set of 11/ v3KV / 110/ v 3 Volt, 100 VA burden and accuracy class 0.5, single phase construction, dry type cast resin PT. 3 Nos. of dual core 50/5A, 15 VA burden, accuracy class CL 0.5, 33 KV cast resin CTs , One Set of Phase Indicating Lamps, 2 Sets of HRC fuses with fuse base (H.T. Fuse - 1A and LT fuse 2-6A).,2 Nos. indoor cable end box suitable for 3C x 300 sq.mm. 11 KV(E), aluminum conductor XLPE Ar. cable (Incoming and Outgoing cable).,1 No. SEB approved digital Trivector meter with MDI in KVA of accuracy class - 0.5.(Accuracy class shall be as per local board),Note: The contractor shall get the Trivector meter, CTs` and PT tested by SEB and the charges for lesioning for the same will be paid extra.. |
| 86 | Design, manufacture, supply, delivery including supervision during installation, testing and commissioning of 1 panel, 11KV HT VCB switch board with following accessories: type tested Indoor Air insulated 11KV up to 2500A, 26.3kA / 40kA (3sec), 3 Phase, metal clad, horizontal draw out type Switchboard with vacuum circuit breaker,a.1No. incoming panel equipped with following:-630A, 11KV, VCB 25 KA, TP, totally enclosed, air insulated metal clad housing, cassette mounted horizontal isolation, horizontal draw out type, motorized spring charged, manually operated, trip free, vacuum circuit breaker (VCB) having double isolation features and control devices complete with mechanical with continuous tripping and closing, coil suitable for 24V DC, shunt trip coil, OFF/ON indicators, mechanical operation counter and provided with following:Spring charge / discharge mechanical OFF push buttons for emergency trip (test / service position limit switches with 6 NO/6 NC breaker auxiliary contacts in service position and The cubicle shall be of LSC 2B (Loss of Service Continuity) and PM (Partition Class) classes as defined by IEC standard 62271-200. And it shall comprise three high voltage compartments and one LV cabinet,CT chamber with single wound single phase, dual core cast resin CT, 15VA burden with core-1 for metering (CL-0.5) and core-2 for protection (CL-5P10) and of 110/5 plus 5A ratio.,Wireless communication energy sensor that monitors and measures energy and power in real-time is required so that can count on operational efficiency and uptime.,Microprocessor based relay, IDMT, Time delay with 3 elements for over current (50-200%) and 1 element for earth fault protection(10-40%) .-1 Set,Antipumping relay and master trip relay- 1 Set,Digital Ammeter with selector switch.-1 Set,A set of breaker ON/OFF/Trip/DC control supply/ Spring Charged indication lamp. 1 Set,Emergency trip push button on front door 1 Set,Limit switches with 6 NO/ 6 NC breaker auxiliary contacts 1 Set,Control:- T-N-C (Trip, Neutral, Close) breaker control switch. 1 Set,Space heater with thermostat for moisture absorption. 1 Set,Suitable for connection to 2 Runs x 3 core x 300 sq.mm. Cross linked polythelene (XLPE) 11KV cables or as called for. 1 Set,HT Danger Plate 1 Set,Hooter low intensity 24 Volt with acknowledge and reset push button 1 Set,6-window microprocessor based annunciation panel with audio and visual indicator.,Over current and earth fault - 2 windows,Master trip operated - 1 window,Spare - 3 windows,Surge Arrestor, 10KA, Class II 1 Set,Thermal monitoring shall be fitted on HV field cable/busbar connections,The monitoring shall be done by a battery less sensor that communicates wirelessly using Zigbee Green Power protocol.,1 Nos Incoming as described above.,b. Bus Bars:-800A, 11KV, 25 KA, 3 phase, air insulated Electrolytic grade Al bus bars,c.2 Nos Feeder panel for, equipped with following :-1 nos. 630A, VCB 11KV 25 KA, TP, Totally enclosed, air insulated, metal clad housing, cassette mounted horizontal isolation, horizontal drawout type, motorised spring charged, manually operated, trip free,each vaccum circuit breaker having double isolation features and control devices complete with mechanical with continous tripping and closing, coil suitable for 24V DC, shunt trip coil OFF/ON indicators mechanical operation counter and provided with each feeder following:-Spring charge / discharge mechanical OFF push buttons for emergency trip (shrouded) test / service position limit switches with 6 NO / 6 NC breaker auxliary contacts in service position.The busbars shall be rated for continuous current, at 40°C ambient temperature. Temperature rise shall be as per IEC 62271-200.,The bus bars shall be sleeved for full voltage. Sleeve shall be heat shrinkable BTPM type of Reychem / equivelent make. No PVC sleeving in bus bar for 11 KV is acceptable,CT chamber with Dual core, single phase, Single ratio cast resin CT, 15VA burden with core-1 for metering (CL-0.5) ,core-2 for protection (CL-5P10),Digital Ammeter with selector switch, shrouded terminals, square size.The busbars shall be located in a separate metal clad chamber and shall be air insulated. Bus bars shall be extendible on either side,Microprocessor based IDMT instantaneous relay with 3 O/C (50-200%) and one E/F protection (10-40%). To maintain safety of the Indoor switchgear and Human resources in case of any internal ARC fault and also minimize the damage, maintenance cost and downtime of the system, the system should have ARC flash protection system with ACTIVE Arc flash protection,Antipumping relay and master trip relay,A set of breaker ON/OFF/Trip/DC control supply/Trip circuit healthy and R,Y, B phase indication lamps.,Required Auxiliary relays for WTI (Winding temperature indication with alarm and trip),8-window annunciation panel with audio and visual indication,8 Over current and earth fault - 2 windows,Master trip operated - 1 window, |
| 87 | Supplying / Receiving, Installation, Testing and Commissioning of Powder coated, 14 SWG CRCA sheet steel enclosed 11KV H.T. Metering Panel complete with the following:BUSBAR-1,From 500 KVA Transformer-1,1 No. 800A 4 pole microprocessor based EDO, ACB(35kA) with integral protection as per PRMB-1 mentioned in Premable,1 set of 800/5A, 15 VA, class-0.5 CTs for APFC relay,1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB,1 No. (0-800A) Ammeter with ASS with 3 nos. 1000/5A CT`s,1Set- of ON/OFF/Trip/ Spring Charged and Trip circuit healthy indicating lamps.,240 V AC Motor wound spring closing mechanism,1 - 24 volts DC shunt trip coil,6 nos NO/NC contacts for remote opening and closing, Terminals to receive XLPE insulated Aluminum cables, Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.,Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order and %THD with RS485 port,From DG-1 No. 200A 4 pole microprocessor based MCCB, ACB(35kA) with integral protection as per PRMB-1 mentioned in Premable,1 set of 200/5A, 15 VA, class-0.5 CTs for APFC relay,1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.,1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB,1 No. (0-200A) Ammeter with ASS with 3 nos. 1000/5A CT`s,Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order and %THD with RS485 port,240 V AC Motor wound spring closing mechanism,1 - 24 volts DC shunt trip coil,6 nos NO/NC contacts for remote opening and closing,Terminals to receive XLPE insulated Aluminium cables,Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.,Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order and %THD with RS485 port,Emergency Push Button,TNC Breaker Control switch.BUS BARS-Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 800 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at 433 volts. The neutral busbar is to be of 50% capacity.,OUTGOINGS-Bus Section-1-1 No.400A FP MCCB (35 KA) complete with:3 nos 400/5A Class - 0.5, 15 VA Burden CT`s for metering,ON / OFF indicating lamps with MCB as backup protection.,Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of Accuracy-1 as specified.,2 No.200A FP MCCB (35 KA) complete with,3 nos 200/5A Class - 0.5, 15 VA Burden CT`s for metering, ON / OFF indicating lamps with MCB as backup protection. Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of Accuracy-1 as specified.3 No. 100A FP MCCB(25KA) complete with:3 nos 100/5A Class - 0.5, 15 VA Burden CT`s for metering, ON / OFF indicating lamps with MCB as backup protection. Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of Accuracy-1 as specified.BUS COUPLER - 1-1 No. 800Amps, 35KA, 433 volt 4-P EDO ACB without release complete with following:,6 Nos. NO/NC contacts for remote opening and closing,Red/Green / Amber / ON/OFF / Trip indicating lamps with 2A SP MCB as backup protection.,Backup MCB and terminal blocks as required.,TNC Breaker Control switch, Required Interlocking with other incomers and Bus Coupler to be provided as per Interlocking / operation scheme.BUSBAR-2-1 No. 800A 4 pole microprocessor based EDO, ACB(35kA) with integral protection as per PRMB-1 mentioned in Premable,1 set of 800/5A, 15 VA, class-0.5 CTs for APFC relay,1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.,1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB,1 No. (0-800A) Ammeter with ASS with 3 nos. 1000/5A CT`s,1Set- of ON/OFF/Trip/ Spring Charged and Trip circuit healthy indicating lamps.,240 V AC Motor wound spring closing mechanism,1 - 24 volts DC shunt trip coil,6 nos NO/NC contacts for remote opening and closing,Terminals to receive XLPE insulated Aluminium cables,Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.,Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order and %THD with RS485 port,BUS BARS,Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 800 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 35 kA at 433 volts. The neutral busbar is to be of 50% capacity.,OUTGOINGS-Bus Section-21 No. 400A FP MCCB (35 KA) complete with.,3 nos 400/5A Class - 0.5, 15 VA Burden CT`s for metering,ON / OFF indicating lamps with MCB as backup protection.Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of Accuracy-1 as specified.1 No. 200A FP MCCB (35 KA) complete with.2 nos 200/5A Class - 0.5, 15 VA Burden CT`s for metering,ON / OFF indicating lamps with MCB as backup protection.Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of Accuracy-1 as specified.3 No. 100A FP MCCB (25 KA) complete with.6 nos 100/5A Class - 0.5, 15 VA Burden CT`s for metering,ON / OFF indicating lamps with MCB as backup protection.Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of Accuracy-1 as specified. |
| 88 | Supplying / Receiving, Installation, Testing and Commissioning of Powder coated, 14 SWG CRCA sheet steel enclosed 11KV L.T. Metering Panel complete with the following: FLOOR PANEL (GR,1ST,2ND,3RD),1 No 200 A FP MCCB,METERING and INDICATION for each Incomer,1 set of R,Y,B phase indicating lamps,Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order and %THD) with RS-485 Port.,Sets of 200/5A, CL-1, 15VA CTs for measuring.Sets of phase indicating lamp with 2A control MCBs.,BUS-BAR,250A TPN Aluminium Bus Bar with colour coded PVC Sleeves, OUTGOINGS-6 No. 63amps 4P MCB,6 No. 40amps 4P MCB |
| 89 | Supplying / Receiving, Installation, Testing and Commissioning of Powder coated, 14 SWG CRCA sheet steel enclosed 11KV L.T. Metering Panel complete with the following: 1 No 100 A FP MCCB,METERING and INDICATION for each Incomer,1 set of R,Y,B phase indicating lamps,Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order and %THD) with RS-485 Port.,Sets of 200/5A, CL-1, 15VA CTs for measuring.Sets of phase indicating lamp with 2A control MCBs.,BUS-BAR,250A TPN Aluminium Bus Bar with colour coded PVC Sleeves, OUTGOINGS-6 No. 40amps 4P MCB, |
| 90 | Supplying / Receiving, Installation, Testing and Commissioning of Powder coated, 14 SWG CRCA sheet steel enclosed 11KV L.T. Metering Panel complete with the following: 1 No 100 A FP MCCB,METERING and INDICATION for each Incomer,1 set of R,Y,B phase indicating lamps,Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order and %THD) with RS-485 Port.,Sets of 200/5A, CL-1, 15VA CTs for measuring.Sets of phase indicating lamp with 2A control MCBs.,BUS-BAR,250A TPN Aluminium Bus Bar with colour coded PVC Sleeves, OUTGOINGS-2 No. 40amps 4P MCB, |
| 91 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid andprotected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 92 | Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 93 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 94 | Supplying, Installation, Testing and commissioning of Wifi Router with complete accessories etc. as required. |
| 95 | Construction of 224 bedded SC Boys Hostel at Indira Gandhi University Meerpur, Rewari Please Enable Macros to View BoQ information |