| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. ( DSR ch-15 S.No.- 15.56, Page No. 243 ) |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ( DSR ch-4 S.No.- 4.1.8, Page No. 103 ) |
| 3 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (DSR S.No.- 11.41.2, Page No. 194) |
| 4 | Providing and laying in position ready mixed or site batched design mix M-25 cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, cement, admixtures in recommended proportions as per IS: 9103, in all works above plinth level, including pumping of concrete to site of laying, laying, vibrating, curing etc. complete but excluding the cost of centering, shuttering and reinforcemen all complete as per DSR 2023 item no. 5.33.2.1, Page No. 120 |
| 5 | Water proofing treatment of RCC sunshade with Zycosil/equivalent water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred first & 2 litres of Zycoprime/equivalent added and stirred (total 23 litres)) till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls. ( DSR S.No.-26.60, Page No. 370 ) |
| 6 | Steel reinforcement for R.C.C. work ready to use \\" cut and bend\\" rebars of approved make from factory/ wrkshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more.( DSR S.No.- 5.22C.1, Page No. 119 ) |
| 7 | Providing and fixing angle iron frames for doors , windows and ventilatorsof mild steel angle sections of size 40 x 40 x 5 mm, joints mitred and welded by angle iron 40 x 40 x5 mm or 35 x5 mm flat pieces to the existing T- iron frame or to the wall with dash fastners, including fixing of neccessary butt hinges and screws and applying a priming coat of approved steel primer , all complete as per the direction of Engineer - in - charge ( DSR S.No.- 10.31, Page No. 186 ) |
| 8 | Supply and fixing of 10 cm internal dia PVC (6 kg/per sq.cm.pressure 10 cm dia pipe make complete with bands with door et top and plain at bottom and grating and incliding supply of necessary M.S. clamps 22.5 cmx3 mm fixed to walls . (SOR Rampur S.I. 730(A) Page No. 36) |
| 9 | 15 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) ( DSR S.No.- 13.5.2, Page No. 217 ) |
| 10 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) ( DSR S.No.- 13.4.2, Page No. 217) |
| 11 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.( DSR S.No.- 13.46.1, Page No. 220 ) |
| 12 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre ( DSR S.No.- 13.41.1, Page No. 220 ) |
| 13 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even andsmooth complete. ( DSR S.No.- 13.80, Page No.223 ) |
| 14 | Renewing glass panes, with putty and nails wherever necessary including racking out the old puttyFloat glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR S.No.14.5.1 Page No.229) |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. ( DSR S.No.- 9.20.2, Page No. 150 ) |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work .( DSR S.No.- 13.99, Page No. 224 ) |
| 17 | Brick work with common burnt clay bricks of M-150 class in super structure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) ( DSR S.No.- 6.4.2, Page No. 127 ) |
| 18 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, itable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A (DSR S.No.1.10.1 Page No. 03) |
| 19 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (DSR S.No.1.30 Page No. 08) |
| 20 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.(DSR S.No.1.29 Page No. 08) |
| 21 | Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.(DSR S.No.1.13 Page No. 03) |
| 22 | Supplying and fixing 5A to 32A rating, 240/415V , 10kA \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc as per required : Single pole (E&M 2025 DSR No 2.10.1, Page no 16) |
| 23 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(E&M 2025 DSR No 1.25. Page no 07) |
| 24 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) (E&M 2025 DSR No 9.1.1 Page no 63) |
| 25 | Construction of information piller in brick work with Black Granite stone(2x3) size with B/W in 1:4 in 1.20m.wide wall,23 to 35 cm thickness & 1.35m. Height above G.L. with plaster in 1:4 as per drawing attached I/C digging & painting of letters ,snowcem two coats & I/C all materials,Labour &T&P etc. Complete. Please Enable Macros to View BoQ information |