| 1 | S/F of SP MCB 6 Amp to 32 Amp C-curve type Havells make 10 KA complete in all respect PS No. 1002 (Cat-B) |
| 2 | S/F of 63 Amp FP Isolator Havells make 10 KA complete in all respect PS No. 1007 B (Cat-B) |
| 3 | S/F of 100 amp 415 Volt metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respects PS No. 328 Cat B |
| 4 | S & F surface/Flush mounting 8ways TPN distribution board without additional Door without MCB complete in all respect, as directed at site by Engineer in charge. PS No. 1028 CAT-B |
| 5 | Supply and fixing of LED Tube Light with batten suitable for upto 1x22 watt LED Tube Light fitting including tube on surface. Complete in all respects (PS No. 1413 CAT-AAA) |
| 6 | Supply and fixing of LED Tube Light with batten suitable for upto 2x22 watt LED Tube Light fitting including tube on surface. Complete in all respects (PS No. 1414 CAT-AAA) |
| 7 | S/F of Ceiling fan 1200 mm sweep incl. proper connection. Complete in all respects (AOR) make Usha, Havells, Crompto/ Bajaj |
| 8 | S/F of 12\\" (300mm) Exhaust Fan Khaitan/Almonard Make. Complete in all respects (AOR) |
| 9 | S/F of Electronic Fan Regulator 120-280Volt ISI marked on the existing switch board including making connection, required material, laour T/P etc. for proper completion of work of Anchor/Kinjal make. As per PS No. 1203A |
| 10 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Kalinga, Grandlay, Skytone, Havell's make) |
| 11 | (1) 16 Sq.mm. 4Core (PS No. 501) |
| 12 | (2) 50 Sq.mm. 3.5 Core (PS No. 501) |
| 13 | S/F of cable Lug(socket) to the cable lead. Complete in all respects as per PS No. 504 |
| 14 | (1) 16 Sq.mm. |
| 15 | (2) 50 Sq.mm. |
| 16 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR 14.1663 mm dia A.(OD-63 mm & ID-51 mm nominal) DSR-2018, 14.16.1 |
| 17 | b) 90 mm dia (OD-90 mm & ID-76 mm nominal) (14.16.2) |
| 18 | Supply and buring of safe earthing electrode T-19 (Hot dip galvanized), length up to 2000mm outer type 50mm, inner pipe, 22mm terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip galvanization up to 100 micron filled with crystalline conductive mixture(CCM) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good micture of retaining capicity along with 30cm square C.I. frame with hinged cover & masonry husing from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra as per PS No. 725A |
| 19 | Wiring point for light in 1.5 sq. mm. .FRLSH PVC insulated multistrand single core copper conductor cable (drawn through existing PVC conduit), with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conducter cable as earth wire and 5 Amp.flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminated backalite sheet with brass machine screws and cup washers mounted over existing M.S. switch board box/ junction box with supply of all material, labour & T&P etc. required for proper completion of the work as directed at site by the Engineer in charge. PS No. 174 (C) |
| 20 | Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductoer cable in existing PVC conduit pipe with 1.5 sq. mm .FRLSH PVC insulated multistrand copper conducter cable as earth wire drawn in side the conduit. Complete piano type switch and ceiling rose / angle /betten holder 3mm thick phenolic laminated backelite sheet etc. Complete in all respects as directed including matching colour wash PS No. 177C |
| 21 | Wiring point for Plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductoer cable in existing PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conducter cable as earth wire drawn in side the conduit. Complete piano type switch and 5 pin socket on 3mm thick phenolic laminated backelite sheet etc. Complete in all respects as directed including matching colour wash PS No. 178C |
| 22 | S/F of power plug with15A/240V Flush type switch and 5 pin 15A/250 Flush type universal socket in suitable MS box of 175mmx100mmx50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer as per PS No. 1139 |
| 23 | S/W of submain with 2 Nos. 2.5 sq. mm & with 1 No. earth wire 1.5 sq. mm FRLSH PVC insulated 1100 Volt grade single core Multi strand copper conductor cable in existing PVC conduit complete with supply of all material labour & T&P required for proper completion of the owrk as directed at site by E/I PS No. 291 |
| 24 | S/W of submain with 2 Nos. 4 sq. mm & with 1 No. earth wire 2.5 sq. mm FRLSH PVC insulated 1100 Volt grade single core Multi strand copper conductor cable in existing PVC conduit complete with supply of all material labour & T&P required for proper completion of the owrk as directed at site by E/I PS No. 291A |
| 25 | S/W of submain with 2 Nos. 6 sq. mm & with 1 No. earth wire 4 sq. mm FRLSH PVC insulated 1100 Volt grade single core Multi strand copper conductor cable in existing PVC conduit complete with supply of all material labour & T&P required for proper completion of the owrk as directed at site by E/I PS No. 291D |
| 26 | S/W of submain with 2 Nos. 10 sq. mm & with 1 No. earth wire 6 sq. mm FRLSH PVC insulated 1100 Volt grade single core Multi strand copper conductor cable in existing PVC conduit complete with supply of all material labour & T&P required for proper completion of the owrk as directed at site by E/I PS No. 291G |
| 27 | Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. UPSOR 1403 Please Enable Macros to View BoQ information |