| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, i/c getting ou and disposal of surplus the excavated soil as directed withen a lead of 50m. DSR-2.8.1 |
| 2 | P & L in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate) 40 mm nominal size deliver from natural sources. DSR 4.1.8 |
| 3 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) as per SI No- 6.1.1 |
| 4 | Brick work with common burnt clay bricks of M-150 Class in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand ) as per SI no 6.4.1 |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Lvl as SI No-5.3 |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) as SI No-5.1.2 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Above Plinth Lvl as SI No-5.2.2 |
| 8 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per SI. No.- 5.22 B.1 |
| 9 | 15 mm thick cement plaster of mix 1:4 ( 1 cement & 4 course sand ) rough surface per IS 13.5.1 |
| 10 | 12 mm thick cement plaster of mix 1:4 ( 1 cement & 4 course sand ) rough surface per IS 13.4.1 |
| 11 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame i/c fixing necessory butt,hinge,screw etc. and priming coat.complete as DSR-10.31 |
| 12 | P/F of 1mm thick m.s. Sheet door & window frame with 3mm m.s. Gusset plate at junctios using 30x6mm digonal breces etc.as 10.5.2 |
| 13 | 1:2:4 Cement concrete cement , coarse sand & 20mm nominal size deliver from natural sorces as DSR-4.1.3 |
| 14 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (Under Floor) as per SI.No. 2.25 (a) |
| 15 | Centering and shuttering including strutting, propping etc.and removal of form. Foundation as per SI- 5.9.1 |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form. Column as per SI- 5.9.6 |
| 17 | Centering and shuttering including strutting, propping etc.and removal of form. Slab as per SI- 5.9.3 |
| 18 | Centering and shuttering including strutting, propping etc.and removal of form. Beam / Band as per SI- 5.9.5 |
| 19 | C.c.flooring in 1:2:4 cement,c.sand and 20mm gauge s.grit mix 40mm thick with floating coat of neat cement 3mm thick complete as DSR-11.3 |
| 20 | Forming groove in plaster 12mm x 12mm used approved pattern complete in all respects as per DSR-13.76 |
| 21 | P/F of glass strips of 4 mm.thick and 35 mm.deep in floor comp. as SI.631(a) |
| 22 | Providing & applying white cement based wall putty of avrage thickness 1mm of approvel brand & mfd.to prepaterd the surface even and smooth complete as DSR-13.80 |
| 23 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per Sl no. -13.46.1 Two Coats |
| 24 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and inclu |
| 25 | Painting with synthetic enamle paint of app. Brand and Mfd. Of required colour to given an even shede. Two or more coats on new work over on under coat of suitable shade with ordinary paint complete DSR 13.62.1 |
| 26 | Diluting and injecting chemical for preconsruction antitermite treatment in Fd,n-treches,plinth filling,wall and floor etc.comp.as DSR-2.35.3 |
| 27 | S/F of sign bord at site of work comp.in all respects as directed by Er. In-charge. |
| 28 | Wiring point for light / exhaust / Fan / Call bell point with1.5 Sq.mm FRLS PVC insulated multistrand copper conductor single core cable in sueface / recessed medium class PVC conduit with modular type switch , phenolic laminated sheet , suitable size M.S. Box and earthing the point with 1.5 sq.mm.FRLS PVC insulated multistrand copper conductor as required complete as DSR(E&M) -1.10.1 |
| 29 | Wiring point for fan with 1.5Sq.mm FRLS PVC insulated multistrand copper conductor cable complete as DSR(E&M)-1.10.1 |
| 30 | Wiring point for plug with 2x4Sq.mm FRLS /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 2No.4sq.mm. FRLS /HFFR PVC insulated copper conductor single core cable for earthing as equired complete as DSR(E&M)-1.12 |
| 31 | Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.DSR(E&M) 1.13 |
| 32 | S/F of LED tube light with batten fitting sutable for up to 18-22 watt LED tube light fitting i/c tube on surface complete as DSR(E&M)-8.9.1 |
| 33 | S/F of 12 way SPN Double door steel sheet MCB distributor bord on surface / recess complete with tinned copper bus bar,natural bus bar, earth bar din bar,inter connections powder painted i/c earthing etc.complete as DSR(E&M)-2.3.3 |
| 34 | S/F of 6 Amp. To 32 Amp.TP&N disconector fuse or MCB inside the existing panel board with ISI marked HRC fuse i/c drilling hole in cubical panel making connections etc. DSR(E&M)-2.1.1 |
| 35 | S/F of 63 Amp.D.P. Isolator 240V in the existing MCB DB complete with connections testing etc. As DSR(E&M)-2.12.2 |
| 36 | Supply, Instalation ,testing & commissioning of ceilling fan 1200mm with brush less direct current (BLDC) motor ,class of insulation B ,3 Nos metal blades ,30cm. Dowen rod ,350 RPM ,suitable for oreration with regular for speed control, 230V,50Htz.single phase AC ceilling fan complete in all respects as DSR(E&M)-9.2.3 |
| 37 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.DSR(E&M) 1.25 |
| 38 | Supplying and fixing following size/ modules, 8 Module (125mmX125mm) GI box along with modular base & cover plate for modular switches in recess etc. as required.DSR(E&M) 1.27.5 |
| 39 | Supplying and fixing metal box of following sizes 250x300x60 mm (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.DSR(E&M) 1.22.15 |
| 40 | Instalation ,testing and commissioning of cielling fan i/c wiring the down rod of standard length ( up to 30cm ). With 1.5 sq.mm.FRLS PVC insulated multistrand copper conductor single core cable i/c providing & fixing phenolic laminated sheet cover on the fan box etc. complete as DSR(E&M)-1.45 |
| 41 | PVC pipe 100mm dia & 6kg/sq.cm of app.make & quality comp. Item no-22 page14 |
| 42 | S/fixing of 15mm dia G.I pipe with asseceries complete in all respects.as S.no.18.11.1 |
| 43 | S/fixing of 20mm dia G.I pipe with asseceries complete in all respects.as S.No.-18.11.2 |
| 44 | S/fixing of 15mm dia bib cock complete in all respects.s.no.-18.15.1 |
| 45 | P/Fixing of white vitreous china wash basin 630×450mm i/c all connections S.No.17.25.1 |
| 46 | Supply & fixing of W.c.pan indin type with 100mm, trap,10lit.low level flushing sistern i/c all as SI-no-ch.22 new item-17.1.1 |
| 47 | P/F of c.p. brass angle valve for basin and flushing cystern etc comp.18.53.1 |
| 48 | S/F 32 mm dia semi rigid PVC waste pipe for sink and wash basin (ch.24-8) 17.28.1.1 |
| 49 | P/F of 600 ×450mm bevelled edge mirror of superior quality comp. as S.No.-17.31 |
| 50 | P/F of white vetreouschina flat back lipped front urinal basin 430×260×350 & 340×410×265 mm i/c all fittings complete as S.No.-17.4.1 (5 male Urinal & 5 Female Urinal ) |
| 51 | P/placing on tarrace PVC water storege tank Complete in all respects.18.48 |
| 52 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.1 15 mm nominal bore |
| 53 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, i/c getting ou and disposal of surplus the excavated soil as directed withen a lead of 50m. |
| 54 | P & L in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate) 40 mm nominal size deliver from natural sources. |
| 55 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) as per SI No- 6.1.1 |
| 56 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Lvl as SI No-5.3 |
| 57 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per SI. No.- 5.22 B.1 |
| 58 | 20mm thick plaster in 1:3 cement and c.sand mix mortar i/c floating coat of neat cement complete as Ch.-13,N.Item -2 page-36 |
| 59 | 2.5 cm thick p.c.c. floor in 1:2:4 cement,c.sand and s.grit mix mortar i/c base 1:4:8 cement fine sand & 40mm b.ballast complete as SI-601A |
| 60 | P/Laying of 150mm PVC pipe (6kg per sq.cm.) ISI mark i/c cost of pipe also i/c necessary fittings etc.copmplete as DSR-23.3.2 |
| 61 | P/Fixing of bail plug/bottom plug 150mm dia to the bottom of pipe assambly of tube etc comp. as DRS-23.15.2 |
| 62 | Supply and wiring of submain with two nos.2.5 sq.mm flush PVC insulated 1100V multistrand single core copper conductor cable in 20mm dia condute concelled with one 14 swg copper earth wire etec comp. As PWD SOR-1304B |
| 63 | Providing and fixing G.I.pipe 32mm dia nominal bore complete with GI fittings as DSR-18.12.4 |
| 64 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.as DSR-11.37A toilet |
| 65 | Providing and laying Vitrified tiles in [ 600x600mm ] (thickness to be specified by manufacturer), with water absorption less than 0.08 % & conforming to 1.8. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm th 1:3 cement & c.sand mix mortar. complete as DSR-11.46.2 |
| 66 | P/L of integral water proofing treatment i/c preparation of surface as required five stages [Brick Coba] 1-apply cement slurry 2.75kg/sq.m . 2-laying brick bats in 1:5 cement c.sand mix mortar i/c water froofing compound. 3-apply cement slurry 2.75kg/sq.m. 4-Finishing with 20mm 1:4 cement c.sand mix mortar i/c water froofing compound. 5-whole tarace flooded with water for two week mim. |
| 67 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern comp DSR 16.91.2 Please Enable Macros to View BoQ information |