| 1 | Excavation in trenches n exc 1.5 m in depth in any type of soil; for foundation, etc. and getting out including bailing/pumping /dewatering(if required) of water complete all as specified and directed by Engr-In-Charge. |
| 2 | Excavation in trenches exc 1.5 m in depth and n exc 3.00 m in any type of soil ; for foundation, etc. and getting out including baling/pumping /dewatering(if required) of water complete all as specified and directed by Engr-In-Charge. |
| 3 | Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engr-In-Charge. |
| 4 | M & L for spreading and leveling in layers n.exc 25cm thick and well ramming including watering as required under floors (in floor with available earth from excavation) complete all as specified and directed by Engr-In-Charge. |
| 5 | Removing excavated material exc 50m and not exc 250m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 6 | M&L for PCC 1:4:8 type D2 40mm stone aggregate filling mass concrete in foundation complete all as specified and directed by Engr-In-Charge. |
| 7 | Material and labour for providing Reinforced Cement Concrete (Design Mix) M-30 using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc complete all as specified and directed by Engr-In-Charge. |
| 8 | M & L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified and directed by Engr-In-Charge. |
| 9 | Material and labour for providing Reinforced Cement Concrete (Design Mix) M-30 using 20 mm graded aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-In-Charge. |
| 10 | Material and labour for providing Reinforced Cement Concrete (Design Mix) M-30 using 20 mm graded aggregate as in beams, cantilever, chajja,lintels over 1.5 m complete all as specified and directed by Engr-In-Charge. |
| 11 | Material and labour for providing Reinforced Cement Concrete (Design Mix) M-30 using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floor, roof, landing, balcknies, conopies, decks, slab and in shelves and like complete all as specified and directed by Engr-In-Charge. |
| 12 | M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; rough finished vertical or to batter complete all as specified and directed by Engr-In-Charge. |
| 13 | M & L Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished vertical or to batter complete all as specified and directed by Engr-In-Charge. |
| 14 | M & L formwork to sides and soffits of floor or roof beams, beam hunching, girders, lintels, cantlievers, shelves including supports, etc for rough finished flat surfaces of concrete complete all as specified and directed by Engr-In-Charge. |
| 15 | M & L formwork to soffits of suspended slabs such as roof slabs, floor slabs, la ndings and similar work; not exceeding 200 mm thick (Horizontal or slopping) for rough finished flat surfaces of concrete complete all as specified and directed by Engr-In-Charge. |
| 16 | Material and labour for 6 to 8 mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-In-Charge. |
| 17 | Material and labour for 10 mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-In-Charge. |
| 18 | Material and labour for 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-In-Charge. |
| 19 | Material and labour for 100 mm thick sand filling over 150 Micro ploythene film over rammed earth under floors or in foundation including watering and consolidation as specified and directed by Engr-In-Charge. |
| 20 | M&L for hard core of broken brick of guage n.exc 63mm deposited spread and levelled in layer n.exc 15cm thick watered and well rammed to true surfaces as s complete all as specified and directed by Engr-In-Charge. |
| 21 | Material and labour for providing 75 mm thick cement concrete (1:3:6) type C2 using 40mm graded aggregate as in plinth protection surfaces even and smooth without using extra cement including provision of construction joints complete all as specified and directed by Engr-In-Charge. |
| 22 | M & L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and directed by Engr-In-Charge. |
| 23 | M & L Cement concrete 100 mm thick type D-2, 1:4:8 (40mm graded aggregate) as in sub-floors, sub bases, floors and pavings, etc complete all as specified and directed by Engr-In-Charge. |
| 24 | S&F ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, (400 X400 mm) as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles15mm thick screed bed or bedding layer CM 1:4 for laying finishes,complete all as specified as directed by Engr-in- Charge |
| 25 | M&L for granite, 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms etc.over and including 20 mm thick screed bed in cement mortar 1:6 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete as specified and directed. |
| 26 | M & L brick work with fly ash bricks, straight or curved on plan exceeding 6 metre mean radius built in CM 1:6 complete all as specified and directed by Engr-In-Charge. |
| 27 | M & L for Rendering 15mm thick in cement mortar 1:4 on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-In-Charge. |
| 28 | M & L for Rendering 15mm thick in cement mortar 1:6 on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-In Charge. |
| 29 | M&L for 5 mm thick plaster on ceiling/ concrete surfaces in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge. |
| 30 | M&L for preparation of Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed by Engr-In-Charge. |
| 31 | M&L for Preparation of new plastered surfaces and applying applying wall care putty on ceiling of 3 mm thickness over plastered surface to prepare the surface even and smooth and apply one coat of OBD on ceiling as specified & directed by Engr-In-Charge. |
| 32 | M&L for preparation of new surfaces including 3 mm wall care putty on walls over plastered surfaces to prepare surface for receiving distempering two or more coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification including all preparation complete all as specified & directed by Engr-In-Charge. |
| 33 | M & L Rendering 1:3 of mortar 10 mm thick for roof with water proofing compound complete all as specified & directed by Engr-In-Charge. |
| 34 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm.(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger PaintsNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. |
| 35 | Supply of SBR waterproofing compound @ 2% of per Kg cement used complete all as specified and directed by Engineer - in - Charge.Make:- Fosroc / Sika/ Choksey / Chemsol / Bostik/ STP |
| 36 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 37 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 38 | M & L for 4.8 mm thick, plain sheet glass ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters) in Squares any size each complete all as specified and directed by engr-in-charge. |
| 39 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge |
| 40 | S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engr-inCharge. |
| 41 | Supply and fixing 150mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed by engr-in-charge. |
| 42 | S & F 150 mm long aluminium handles, fabricated type, anodised complete all as specified and directed by engr-in-charge. |
| 43 | S&F 100 mm long butt hinges, medium weight, cold rolled, mild steel and fixed complete all as specified and directed by engr-in-charge. |
| 44 | S & F Floor door stopper of aluminium , 75-100 mm cast iron body, with hard drawn steel spring complete all as specified and directed by engr-in-charge. |
| 45 | S&F 250 mm long , Aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by engr-in-charge. |
| 46 | S&F Door closer hydraulically regulated, Aluminium (Extruded section body) designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed complete all as specified. |
| 47 | S&F solid PVC door frame(wooden finish) of size 50mmx47mm made out of 5mm wooden colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawings complete all as specified. |
| 48 | S&F Factory made solid panel pvc moulded door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wooden colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wooden colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wooden colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified.Note : (a) stainless steel (304 grade) finished butt hinges 100mm -04 Nos per leaf.(b) Stainless steel (304 grade) finished square tower bolt 150mm long -02 Nos per leaf.(c) Stainless steel (304 grade) finished handles 150mm -02 Nos per leaf. |
| 49 | M&L for Pressed steel frames (125X60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified and directed by Engineer-In-Charge. |
| 50 | S&F 2nd class hard wood plain framed paneled shutter 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board upto commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated (Factory made shutters) complete all as specified.Note : (a) Stainless steel (304 grade) finished square tower bolt 200mm long -02 Nos per leaf.(b) Stainless steel (304 grade) finished handles 200mm -02 Nos per leaf.(c) Stainless steel (304 grade) finished sliding door bolt 300mm -01 Nos per leaf.(d) Stainless steel (304 grade) finished floor door stopper -01 Nos per leaf. |
| 51 | S&F 2nd class hard wood 35 mm thick glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc divided into squares by Rails and styles, with plain chamfered or rounded mitered and rebated size of members of shutters as specified in SSR Part-I, Section 8, Clause 8.24 (a) complete all as specified.Note : (a) Stainless steel (304 grade) finished square tower bolt 200mm long -02 Nos per leaf.(b) Stainless steel (304 grade) finished handles 200mm -02 Nos per leaf.(c) Stainless steel (304 grade) finished sliding door bolt 300mm -01 Nos per leaf.(d) Stainless steel (304 grade) finished floor door stopper -01 Nos per leaf.(e) Stainless steel (304 grade) wire cloth fixing as per manufacture. |
| 52 | S&F Glazed ceramic coloured tiles with highlighter in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in CM 1:4 on other than fair face of brick work. (Highlighter shall be provided as directed by Engr-in-Charge) |
| 53 | S&F three layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity hoisted and fixed in position all as specified including PVC float valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe & dismantling existing water tank complete all as specified and directed by Engr-in-charge. |
| 54 | S&F 25mm (outer dia) Gate valves (brass insert) as per site requirement with iron wheel head, fixed both ends of pipe. |
| 55 | Supplying and laying of CPVC pipes ISI SDR 11 pipe 20mm dia with all fittings solvent and fixed to wall and Ceiling or laid in floor, bore of pipe 20mm complete all as specified and directed by Engr-in-Charge. |
| 56 | Supplying and laying of CPVC pipes ISI SDR 11 pipe 25mm dia with all fittings solvent and fixed to wall and Ceiling or laid in floor, bore of pipe 25mm complete all as specified and directed by Engr-in-Charge. |
| 57 | S&F vitreous china premium/1st quality wash basin (under counter), white/ivory/off white, size 550x400 mm including S&F all accessories as recommended by manufacturer and incl. CP bottle trap 32 mm with inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union and incl 32mm brass CP waste coupling, CP Brass Pillar tap and complete fixed in position in all respect as per manufacturer's instructions all as specified. |
| 58 | S&F Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like duraplast seat cover, rag bolts/ gel gasket etc and ABS health faucet CP jet spray with 1.50 mtr long fexible tube including fixing arrangement complete in all respect all as specified. |
| 59 | S&F one piece/Single body PVC blow moulded conceled cistern, pneumatic type; capacity 9-10 litres, including chrome finish dual flush control plate, flushing pipe and fixing brackets complete assembled and fixed at site. |
| 60 | S&F Vitreous china bowl half urinal flat back, size of 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws complete with flush pipe and half turn valve 15mm more all as specified and directed by Engineer - in - Charge. |
| 61 | S&F in PVC connection, 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 62 | S&F 6mm thick looking mirror fixed to wall with stainless steel plugs/connecter/spacers/screws etc. chrome finish with wooden beading french polished, etc.complete fixed in position all as specified and directed. |
| 63 | S&F chormium plated fancy type 15 mm size wall mixer, for mixing hot & cold water, cast copper alloy, chromium plated with capstan head comprising bib tap with all connected accessories, fixed complete. |
| 64 | S&F Stop valve/angle ball, cast copper alloy,chromium plated, screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed. |
| 65 | S&F bib tap,fancy type ,chromium plated, with crutch or butter fly handle, screwed down, screwed for 15mm bore pipe & fixed complete all as specified and directed. |
| 66 | S&F Grating doom, 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed |
| 67 | S&F fancy type brass chromium plated shower roses 125mm size with swivel joints, any size including fixing to steel pipe or union all as specified and directed by Engineer - in - Charge. Please Enable Macros to View BoQ information |
| 68 | S&F fancy type brass chromium plated shower roses 125mm size with swivel joints, any size including fixing to steel pipe or union all as specified and directed by Engineer - in - Charge. Please Enable Macros to View BoQ information |