| 1 | Taking down the steel rolling shutter push and type n-exc 25 Sqm area of clear opening each including hood cover and cleaning the sides of shutter suspension and guide shannelks and greasing all the moving parts of rolling shutter shaft and replacement of bolts and nuts as required for smooth functioninig of shutters, incl necessary welding whereever required as directed giving proper tension to the spring and refixing the shutter and gear box including hood cover in same opening after repair work complete all as specified and directed by Engr-in-charge. |
| 2 | All as per item No 01 above but gear operated rolling shutter exc 25 Sqm but n-exc 50 sqm area including adjustment of gear worms assembly complete all as specified and directed by Engr-in-charge. |
| 3 | S&F in repair mild steel lock plates/ handles made out of MS flat 35x5 complete all as specified and directed by Engr-in-charge. |
| 4 | S&F in repair mild steel helical wire spring (Confirming to IS 6248-1970) of gauge 1 of approved make for rolling shutter size upto 30 Sqm complete all as specified and directed by Engr-in-charge. |
| 5 | S & F in repairs MS gear assembly complete including connecting and fixing the gear box to wall with 4 nos hexagonal bolts 10mm dia 10 cm long complete and grouting the bolt in cement mortar in 1:3 complete all as specified and directed by Engr-in-charge. |
| 6 | S & F in repair in MS hood cover made out of mild steel sheets 1.00mm thick including bending the steel sheets to required shape and fixing the sheet to the rolling shutters bracket plate including with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed by Engr-in-charge. |
| 7 | S & F in repairs of roller ball bearing ISI marked for 40mm dia pipe shaft complete all as specified and directed by Engr-in-charge. |
| 8 | Supply only MS gear handles of approved make for gear operated rolling shutters complete all as specified and directed by Engr-in-charge. |
| 9 | S&F for Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type thickness of laths 1.00 mm etc. as required complete all as specified and directed by Engr-in-charge. |
| 10 | S&F in repairs interlocking lath section formed (confirming to IS 6248-1970) from rolled MS Strip for rolling shutter (of existing width ) 1.00 mm thick complete all as specified and directed by Engr-in-charge. |
| 11 | M & L for preparation of new steel surface of any description over 10 cm in width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 12 | Preparation of old painted steel surface and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-charge. |
| 13 | M&L for repair of MS door of area n.exec 15.00 Sqm area to make fully functional by necessary welding, greasing, denting, oiling,one coat of synthetic enamel painting etc and fixing by repairing small parts like gate hingrs, steel handles, Al drops (16mm dia Bars) etc. complete all as specified and directed by Engr-in-charge. |
| 14 | Dismantling wrought iron or mild steel work of any description not otherwise provided for including necessary steel double scaffolding complete all as specified and directed by Engr-in-charge. |
| 15 | S & F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. upto 15 m ht of bldg complete all as specified and directed by Engr-in-charge. |
| 16 | S & F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engr-in-charge. |
| 17 | S & F rolled mild steel in Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete complete all as specified and directed by Engr-in-charge. |
| 18 | Dismantling of CGI / Poly Carbonate /Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings upto 15 m ht of bldg including necessary steel double scaffolding complete all as specified and directed by Engr-in-charge. |
| 19 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-charge. |
| 20 | S & F in repair Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, bend to curve where required and fixed with self tapping screws upto 15 m ht of bldg complete all as specified and directed by Engr-in-charge. |
| 21 | Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-charge. |
| 22 | M&L Brick work with Fly ash bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 complete all as specified and directed by Engr-in-charge. |
| 23 | Taking down cement or cement lime plaster, any description, roof plaster, plaster on chajjas , parapet on brick walls,roof etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed by Engr-In-charge |
| 24 | M&L Rendering 15mm thick in cement mortar 1:4 on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-In-Charge. |
| 25 | M&L Rendering 10mm thick in cement mortar 1:6 on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-In-Charge. |
| 26 | M&L Rendering 10mm thick in cement mortar 1:3 on ceiling or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-In-Charge. |
| 27 | M& L Preparation of newly plastered surfaces of Ceiling etc., and applying two coats of white wash complete all as specified & directed by Engr-In-Charge. |
| 28 | M& L for Preparation of newly plastered surfaces of walls etc, and applying wall putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and distempering walls with 2 coats of distemper oil emulsion complete all as specified & directed by Engr-In-Charge. |
| 29 | Preparation of newly plastered surfaces of walls etc., and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed by Engineer -in -Charge. |
| 30 | Preparation of old plastered surfaces of walls etc., and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed by Engineer -in -Charge. |
| 31 | Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material upto a distance n.exc 100m where directed, complete all as specified and directed by Engr-in-charge. |
| 32 | Demolition of mud in roof, any thickness including plastering and leaping (whether full thickness removed or only a part thereof) and disposal off rubbish upto a distance n.exc 100m, where directed complete all as specified and directed by Engr-in-charge. |
| 33 | M&L for levelling course for roof slab, Type B0, 1:2:4 (12.5 mm graded aggregate) using waterproofing compound (SBR) for maintaining proper roof slope and finishing cement concrete surface even and smooth without using extra cement complete all as specified.(Minimum thickness of concrete should not be less than 50mm at any point) complete all as specified and directed by Engr-in-charge.Note : Waterproofing compound should be measured and paid separately. |
| 34 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm.(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger PaintsNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. |
| 35 | Supply of SBR waterproofing compound @ 2% of per kg cement used complete all as specified and directed by Engr-in-charge.Make : Fosroc/Sika/Choksey/Chemsol/Bostik/STP/Asian Paints / Berger Paints |
| 36 | S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-charge. |
| 37 | Dismantling CI/PVC pipe upto 100mm bore complete all as specified and directed by Engineer in Chrge. |
| 38 | S & F PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors/Walls complete all as specified and directed by engr-in-charge. |
| 39 | All as per Item No 38 here in before but 110mm bore pipe complete all as specified and directed by Engr-in-charge. |
| 40 | S&F in PVC (SWR) bend any radius 110 mm bore complete all as specified and directed by Engr-in-charge. |
| 41 | Demolition of unreinforced cement concrete in ground floor, plinth protection, paving not exceeding 15 cm thick (below or above ground level) complete all as specified & directed by Engr-In-Charge. |
| 42 | M&L for 100 mm thick cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregates) as in path, hard standing/mass concreteing finishing surfaces even and fair complete all as specified and directed by Engr-in-charge. |
| 43 | Disconnecting and Refixing old 500 Ltrs but n exc 1000 Ltrs capacity Rotational moulded polyethylen water storage tank after cleaning and removing all scale and dirt etc from tanks and from mouths of cirulating pipes etc complete all as specified and directed by Engr-in-charge. |
| 44 | Taking up or down 15/20mm dia GI/PVC Tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed by Engr-in-charge. |
| 45 | Supplying and laying of CPVC pipes ISI SDR 11 pipe 20mm dia with all fittings solvent and fixed to wall and Ceiling or laid in floor, bore of pipe 20mm complete all as specified and directed by Engr-in-Charge. |
| 46 | Taking up or down 25mm dia GI/PVC Tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed by Engr-in-charge. |
| 47 | Supplying and laying of CPVC pipes ISI SDR 11 pipe 25mm dia with all fittings solvent and fixed to wall and Ceiling or laid in floor, bore of pipe 25mm complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F in repair Rotational moulded polythylene 500 ltrs capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including brass float valve 20 mm bore, high pressure with polythene ball & float & dismantling of old water tank complete all as specified and directed by Engr-in-charge. |
| 49 | S&F in repair Rotational moulded polythylene 1000 capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including Brass float valve 20 mm bore, high pressure with polythene ball & float & dismantling of old water tank complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |