| 1 | Taking down Chowkhats or frames exc 1.5 sqm but n exc 4 sqm each without taking off shutters from the frames complete all as specified and directed by the Engg-in-Charge. |
| 2 | Taking down chowkhats or frames not exc. 1.5sqm each complete all as specified and directed by the Engg-in-Charge. |
| 3 | S&F solid PVC door frame of size 50x47mm made out of 5mm thick PVC sheet reinforced with mild steel square tube complete all as specified and directed by the Engg-in-Charge. |
| 4 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed by the Engg-in-Charge. |
| 5 | S&F second class soft wood (KAIL) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by the Engg-in-Charge. |
| 6 | S&F second class soft wood (KAIL) plain, framed, panelled shutters (any number of panels), 35 mm thick with panels of 9mm ply BWP commercial type or 12 mm thich of veneered particle board with commercial veneering both faces as in doors, complete all as specified and directed by the Engg-in-Charge. |
| 7 | S&F 30mm thick second class soft wood (KAIL) glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by the Engg-in-Charge. |
| 8 | S&F butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed by the Engg-in-Charge. |
| 9 | S&F butt hinges medium weight cold rolled mild steel of 75 mm long complete all as specified and directed by the Engg-in-Charge. |
| 10 | S&F anodised aluminium barrel tower bolt extruded sections 100 mm size complete all as specified and directed by the Engg-in-Charge. |
| 11 | S&F 300mm long aluminium alloy, anodised sliding door bolt with hasp staple ( bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed by the Engg-in-Charge. |
| 12 | S&F Aluminum Anodised barrel tower bolts of extruded section, 150mm long complete all as specified and directed by the Engg-in-Charge. |
| 13 | S&F anodised aluminium handle, cast type anodised section 150mm size complete all as specified and directed by the Engg-in-Charge. |
| 14 | S&F sheet glass 3.00mm thick ordinary quality, and glazing with oil putty in square nexc. 0.50 Sqm each pane complete all as specified and directed by the Engg-in-Charge. |
| 15 | Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by the Engg-in-Charge. |
| 16 | S&F 9mm thick prelaminated particle board, interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails to timber frame work in ceiling or sloping complete all as specified and directed by the Engg-in-Charge. |
| 17 | Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40Sqcm, in any position as in unframed work, complete all as specified and directed by Engr-in-Charge. |
| 18 | S&F second clas soft wood fillets square or rectangular in section sectional area exceeding 13sqcm and nexc 25sqcm as in scantling secured with nails or brads complete all as specified and directed by the Engg-in-Charge. |
| 19 | S&F second class softwood fillets square, rectangular or triangular in section sectional area not exceeding 3 sqcm , clean sawn, secured with nails or brads bullnosed, splayed, chamfered or rounded on one edge or face as in cover fillets, complete all as specified and directed by the Engg-in-Charge. |
| 20 | S&F second class softwood moulding as in cornices, picture rails and the like sectional area not exceeding 6 Sqcm fixed with nails complete all as specified and directed by the Engg-in-Charge. |
| 21 | Dismantling timber scantlings 40 sqcm and over in section, in any position complete all as specified and directed by the Engg-in-Charge. |
| 22 | M&L Second class soft-wood in scantlings 40 sqcm and over in section, in any position complete all as specified and directed by the Engg-in-Charge. |
| 23 | M&L for prepration of new wooden surfaces of any description, not otherwise descri-bed over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by the Engg-in-Charge. |
| 24 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by the Engg-in-Charge. |
| 25 | M&L for pre-cast cement concrete block masonry 1:3:6 type C-1 using 20mm graded stone aggregate with solid blocks, exc. 10cm in width and setting in mortar 1:6 complete all as specified and directed by the Engg-in-Charge. |
| 26 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by the Engg-in-Charge. |
| 27 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 finishing of surface even and smooth with out using extra cement complete all as specified and directed by the Engg-in-Charge. |
| 28 | M&L for preparing new plastered surfaces of wall applying two coats of cement paint all as specified and directed by Engr-in-Charge. |
| 29 | M&L rendering 15mm thick cement plaster in cement mortar (1:6) finished even & smooth without using extra cement on brick/concrete surfaces complete all as specified and directed by the Engg-in-Charge. |
| 30 | M&L for two coats of oil bound distemper on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 31 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by the Engg-in-Charge. |
| 32 | M&L for colored joint free Non-skid Ceramic tiles 9 to 10mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed by the Engg-in-Charge. |
| 33 | M&L for coloured glazed ceramic tiles in vertical surfaces 450X 300X 7mm thick, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15mm thick rendering in CM (1:4) complete all as specified and directed by the Engg-in-Charge. |
| 34 | M&L for coloured non-skid ceramic tiles 7 to 8mm thick (square / rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc set and set and jointed in neat cement slurry and pointed in white or coloured cement to match the work including 15 thick screed bed in CM (1:6) complete all as specified and directed by the Engg-in-Charge. |
| 35 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by the Engg-in-Charge. |
| 36 | M&L for chequered cement concrete coloured tiles 300x300x25 mm thick set, jointed and pointed in neat cement slurry and pointed with grey cement and pigment in floors over 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed by the Engg-in-Charge. |
| 37 | M&L for 50mm thick plain cement concrete 1:3:6. type C-2 (using 40mm graded aggregate) as in subbase to floors complete all as specified and directed by the Engg-in-Charge. |
| 38 | M&L for providing, cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by the Engg-in-Charge. |
| 39 | M&L for 75mm thick plain cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in plinth protection finishing of concrete even and smooth without using extra cement complete all as specified and directed by the Engg-in-Charge. |
| 40 | M&L for hardcore with broken stone or boulders of guage exc 63mm but n exc 100mm, deposited, spread and levelled in layers nexc 15cm thick, watered and rolled/rammed to a true surface complete all as specified and directed by the Engg-in-Charge. |
| 41 | Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by the Engg-in-Charge. |
| 42 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 43 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20mm dia pipes complete all as specified and directed by the Engg-in-Charge. |
| 44 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 25 mm dia pipes complete all as specified and directed by the Engg-in-Charge. |
| 45 | S&F 20mm outer diameter 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UVstabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by the Engg-in-Charge. |
| 46 | All as per Item No.45 above but 25mm outer diameter complete all as specified and directed by the Engg-in-Charge. |
| 47 | S&F in repair 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed by the Engg-in-Charge. |
| 48 | Taking down PVC pipe, eaves and gutters (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by the Engg-in-Charge. |
| 49 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 50 | S&F 110mm bore PVC (SWR) bends with oval access door any radius complete all as specified and directed by the Engg-in-Charge. |
| 51 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 52 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed by the Engg-in-Charge. |
| 53 | S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 54 | S&F 75mm bore PVC (SWR) bends with oval access door any radius complete all as specified and directed by the Engg-in-Charge. |
| 55 | S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 56 | S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed by the Engg-in-Charge. |
| 57 | M&L for two coats of cement based paint on old plastered surfaces of walls including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 58 | M&L for two coats of Oil bound distemper on old plastered surfaces of walls including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 59 | S&F in repairs stainless steel squatting pan of pattern “long pan”, size 580x440mm with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge. |
| 60 | S&F in repairs 10ltrs capacity PVC valveless syphonic action type low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed by the Engg-in-Charge. |
| 61 | S&F in repair 15mm bore bib taps standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge. |
| 62 | S&F in repair 15mm bore dia angle valves of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge. |
| 63 | S&F in repairs 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by the Engg-in-Charge. |
| 64 | S&F in repair 15mm bore PVC connection 600mm long both ends screwed with brass cap all complete all as specified and directed by the Engg-in-Charge. |
| 65 | S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by the Engg-in-Charge. |
| 66 | M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in CM 1:4, complete all as specified and directed by the Engg-in-Charge. |
| 67 | M&L for stone masonry walling of random rubble,uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed by the Engg-in-Charge. |
| 68 | Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and directed by the Engg-in-Charge. |
| 69 | M&L for precast cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates as in lintels, landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 70 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, ending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engg-in-Charge. |
| 71 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by the Engg-in-Charge. |
| 72 | S&F Angle Iron (and FI, staging for water tank and the like including caps bases splices etc built up from two or more beam or channel section angle with plate including all lattice bars stiffenes gusset plate etc (Fe-290quality A) complete all as specified and directed by the Engg-in-Charge. |
| 73 | M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer including preparation of surface complete all as specified and directed by the Engg-in-Charge. |
| 74 | Dismantling PVC water tanks of capacity exc 500 but n exc 1000 ltr and removing to store complete all as specified and directed by the Engg-in-Charge. |
| 75 | S&F 1000 ltr capacity rotationally moulded polythene water storage tanks (cylindrical vertical with closed top) multilayers layers of approved make hoisted & fixed at position complete all as specified and directed by the Engg-in-Charge. |
| 76 | S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls complete all as specified and directed by the Engg-in-Charge. |
| 77 | S&F Solid PVC Wall Lining consisting of 5mm thick wood grain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed by the Engg-in-Charge. |
| 78 | S&F 2mm Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed by the Engg-in-Charge. |
| 79 | Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed by the Engg-in-Charge. |
| 80 | S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and directed by the Engg-in-Charge. |
| 81 | M&L for 25mm thick plain cement concrete 1:2:4. type B-0 (using 12.5mm graded aggregate) as sub-base to floor tiles complete all as specified and directed by the Engg-in-Charge. |
| 82 | M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, mass filling , sub base and the like complete all as specified and directed by the Engg-in-Charge. |
| 83 | M&L PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed by the Engg-in-Charge. |
| 84 | S&F in repair 15mm bore Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-110gms) complete all as specified and directed by the Engg-in-Charge. |
| 85 | S&F in repairs vitreous china wash hand basin (flat black) white of size 550x400mm with pedestal excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size complete all as specified and directed by the Engg-in-Charge. |
| 86 | S&F in repairs 32mm dia Waste coupling of CP brass for WHB including waste pipe complete all as specified and directed by the Engg-in-Charge. |
| 87 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) with Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by the Engg-in-Charge. |
| 88 | S&F in repair curtain rails anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by the Engg-in-Charge. |
| 89 | S&F in repair 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by the Engg-in-Charge. |
| 90 | S&F Aluminum Anodised barrel tower bolts of extruded section, 200mm long complete all as specified and directed by the Engg-in-Charge. |
| 91 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed by the Engg-in-Charge. |
| 92 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 93 | M&L Fe 290 (Gde E-165) for roof trussed (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by the Engg-in-Charge. |
| 94 | S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts and washers, in roofs, walls in curve shape etc. with grade of zinc coating 275 complete all as specified and directed by the Engg-in-Charge. |
| 95 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 96 | M&L for Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 97 | M&L for Point wiring for light/fan with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point controlled by one switch. |
| 98 | All as per Srl item No. 97 here in before but for one 3 pin 5 Amps socket outlet on same board. |
| 99 | All as per Srl item No 97 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 100 | All as per Srl item No 97 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 101 | S&F Switch piano flush type 5 Amps, single pole one way complete all as specified and directed by the Engg-in-Charge. |
| 102 | S&F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type complete all as specified and directed by the Engg-in-Charge. |
| 103 | S&F Switch socket combination 2 in 1, 5 and 15Amps flush type complete all as specified and directed by the Engg-in-Charge. |
| 104 | S&F Socket Outlet 2 in 1, 5Amp flush type complete all as specified and directed by the Engg-in-Charge. |
| 105 | M&L of ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed by the Engg-in-Charge. |
| 106 | S&F in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and directed by the Engg-in-Charge. |
| 107 | S&F LED lights fitting, surface mounting general purpose ultra slim economical LED batten of 1x 18W, lumen out put 100lm/wattt, CCT:6500K/3000K, PF>0.9, in extruded PC housing and round/square shaped diffuser including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by the Engg-in-Charge. |
| 108 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 16 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 109 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 110 | S&F in replacement 240V 10KA C curve MCB SPN 32Amp in the MCB DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 111 | S&F in replacement 240V 10KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 112 | S&F in replacement 240V 10KA C curve MCB SP 6 to 32Amp in the MCB DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 113 | S&F LED flood light 70watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete including connecting to to celling rose with suitable size cable complete all as specified and directed by the Engg-in-Charge. |
| 114 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250 mm including making arrangement for fixing complete all as specified and directed by the Engg-in-Charge. |
| 115 | M&L for Earthing complete with galvanised steel earth plate electrode 60x60cm,6mm thick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing on completion.Notes : (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate,(ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same. |
| 116 | S&F in replacement 1100volts grade heavy duty 6Sqmm 2core flat cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by the Engg-in-Charge. |
| 117 | S&F in replacement 1100volts grade heavy duty 16Sqmm 2core flat cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by the Engg-in-Charge. |
| 118 | S&F in replacement LED light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up two core flexible copper conductor cable of suitable size complete all as specified and directed by the Engg-in-Charge. |
| 119 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 12way with 200Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 120 | S&F in replacement Sheet metal enclosure for DB's Single door, single pole and neutral, 240V, 4way with 200Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 121 | M&L for submain wiring comprising single core, 2 Runs of 10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 2mm thick PVC Casing Caping ISI Marked(heavy duty) and its fittings on surface/recessed complete including 1x6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS including taking down old UNSV submain wiring and making good the disturbed surface complete all as specified and directed by Engr-In-charge.(Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 122 | Supply, laying incl testing of XLPE, LT cable armoured, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100V grade with stranded aluminium conductor having cross sectional area 16Sqmm 2core and conforming to IS-7098(Part-I-1988 & as per latest amendments), laid in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles including taking down of existing cable complete all as specified and directed by the Engg-in-Charge. |
| 123 | S&F in replacement 1100volts grade heavy duty 10Sqmm 2core flat cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by the Engg-in-Charge. |
| 124 | Note : Deduction for amount of Rs. 1,14,133.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |