| 1 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by the Engg-in-Charge. |
| 2 | Demolition of Stone slabs and tiles of any description or thickness in floors etc, laid, bedded and pointed in any mortar complete all as specified and directed by the Engg-in-Charge. |
| 3 | M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match shade with joint free non skid tiles over screed bed as bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified and directed by the Engg-in-Charge. |
| 4 | M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in vertical surfaces such as skirting, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 as backing coat for dado, skirting etc complete all as specified and directed by the Engg-in-Charge. |
| 5 | M&L for glazed ceramic coloured tiles of size 300X250X7mm/ 450X300X7mm thick as in vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 as backing coat for dado, skirting etc complete all as specified and directed by the Engg-in-Charge. |
| 6 | M&L for machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing polishing etc complete all as specified and directed by the Engg-in-Charge. |
| 7 | M&L for machine cut kota stone slab as in skirting 20-25mm thick over and including 10 mm thick rendering in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing polishing etc complete all as specified and directed by the Engg-in-Charge. |
| 8 | Taking down cement or cement lime plaster, any description on stone walls etc incl raking out joints hacking for key, scrubbing down with water, etc complete all as specified and directed by the Engg-in-Charge. |
| 9 | M&L for rendering 15mm thick cement plaster 1:6 on stone masonry surface or surface other than fair face of brickwork surface finished even and smooth complete all as specified and directed by the Engg-in-Charge. |
| 10 | M&L 15mm thick rendering in cement mortar 1:4 to stone masonry wall surfaces including patches or on other than fair faces of brick masonary finished even and smooth without using extra cement complete all as specified and directed by the Engg-in-Charge. |
| 11 | M&L for preparing newly plastered surfaces and applying applying two coats of distemper oil emulsion by roller white or tinted over and including one coat of 1mm thick wall care putty complete all as specified and directed by the Engg-in-Charge.Make - Berger / Nerolac / Assian or techno commercially equivalent. |
| 12 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed by the Engg-in-Charge.Note: Steps to be followed for cement base paint (a) Curing the surface by spray gun (b) applying one coat of primer (c) Applying one coat of cement base paint (d) Curring the surface by spray gun (e) Applying second coat of cement base paint after that curing the surface by spray gun |
| 13 | M&L for complete removal of existing treatment from wall and preparation of old decorated wall surfaces by brooming down or steel wire brushing scraping cown smoke shoot moulds mass and efflorescrent salts and trading oil and greasy spot etc and two coat cement base paint complete all as specified and directed by engineer-in-charge Note: Steps to be followed for cement base paint (a) Complete removal of existing treatment by water jet/spray gun (b) Filling of cracks by silka cream 888 group/doctor fixit crack filler (c) Curing the surface by spray gun (d) applying one coat of primer (e) Applying one coat of cement base paint (f) Curring the surface by spray gun (g) applying second coat of cement base paint after 10-12 hrs of Ist coat |
| 14 | Dismantling plain or corrugated steel sheeting, any gauge, thickness in roof coverings complete all as specified and directed by the Engg-in-Charge. |
| 15 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc completed all as specified. |
| 16 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 17 | Dismantling of wall and ceiling boards (fibre, pulp, insulation) or insulation boards /slab /blankets of any description and thickness including frame/grid of any description complete all as specified and directed by the Engg-in-Charge. |
| 18 | M&L for Anodised Aluminium snap grid (minimum 15 microns anodisation) of size 605 x 605 mm with anodized aluminum angle of size 40mm x 25mm x 2mm thick weighing 0.36 Kg per running meter and anodized aluminum main and cross T of size 36.50 x 23.50 x 1.50 mm thick weighing 0.254 Kg per running meter and 23.50 x 23.50 x 1.50 mm thick weighing 0.202 Kg per running meter respectively for false ceiling complete all as specified and directed by the Engg-in-Charge. |
| 19 | S&F hangers 6 mm dia G.I (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long suitable for size of snap grid 605x605 mm complete all as specified and directed by the Engg-in-Charge. |
| 20 | M&L for perforated particle board/ tiles for insulation and accoustic purposes of size 60x60cms, 12mm thick fixed with staples on snap grid in ceiling complete all as specified and directed by the Engg-in-Charge. |
| 21 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed by the Engg-in-Charge. |
| 22 | Disantling of timber scantling, fillets, rails, post, rafters, purlins etc under 40 sqcm as in unfraed work complete all as specified and directed by the Engg-in-Charge. |
| 23 | S&F second class soft wood fillets square, rectangular or triangular in section sectional area exceeding 13sqcm and nexc 25sqcm as in scantling secure with nails or brads complete all as specified and directed by the Engg-in-Charge. |
| 24 | S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in wall complete all as specified and directed by the Engg-in-Charge. |
| 25 | Taking down wooden door / window /CB shutters of any description, area exc 1 sqm but n.exc 2 Sqm each complete all as specified and directed by the Engg-in-Charge. |
| 26 | Taking down wooden door / window /CB shutters of any description, area not exc 1 sqm each complete all as specified and directed by the Engg-in-Charge. |
| 27 | S&F 35mm thick plain framed second class soft wood (KAIL) panelled factory made shutters (two panel) with lock rail and panel of 9mm thick BWP commercial ply with size of rail and stiles as per IS 1003 (part-1), kiln seasoned and chemically pressure treated complete all as specified and directed by the Engg-in-Charge. |
| 28 | S&F 30mm thick 2nd class soft wood (KAIL) glazed and skeleton shutters for windows , open rebated and prepared to receive glass/gauge etc (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass / gauge etc., sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24(b) supplied and fitted to chowkats complete all as specified and directed by the Engg-in-Charge. |
| 29 | M&L 4mm thick sheet glass, ordinary quality and glazing with wooden beading not exc 0.5 Sqm in each pane complete all as specified and directed by the Engg-in-Charge. |
| 30 | S&F 75mm butt hinges medium weight cold rolled mild steel complete all as specified and directed by the Engg-in-Charge. |
| 31 | S&F 100mm butt hinges medium weight cold rolled mild steel complete all as specified and directed by the Engg-in-Charge. |
| 32 | S&F Aluminum alloy sliding door bolt 300 mm long and not less than 12mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by the Engg-in-Charge. |
| 33 | S&F Aluminium barrel tower bolts of extruded section 150mm long complete all as specified and directed by the Engg-in-Charge. |
| 34 | S&F Aluminium barrel tower bolts of extruded section 75mm long complete all as specified and directed by the Engg-in-Charge. |
| 35 | S&F extruded aluminum alloy handles, fabricated type and powder coated, 150mm size complete all as specified and directed by the Engg-in-Charge. |
| 36 | S&F extruded aluminum alloy handles, fabricated type and powder coated, 75mm size complete all as specified and directed by the Engg-in-Charge. |
| 37 | M&L for Two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description over 10cm width or girth including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 38 | M&L for one coats of synthetic enamel on old wooden surfaces of any description over 10cm width or girth including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 39 | M&L for one coat of synthetic enamel paint old steel surfaces of any description over 10cm width or girth including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 40 | S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring over all length of plate 140mm complete all as specified and directed by the Engg-in-Charge. |
| 41 | Demolition of un-reinforced cement concrete in ground floor and pavings n exc 15 cm thick (below or above ground level) and removing all the rubbish complete all as specified and directed by the Engg-in-Charge. |
| 42 | M&L cement concrete type B-1, 1:2:4 (20mm graded aggregate) 25mm thick as in sub base complete all as specified and directed by the Engg-in-Charge. |
| 43 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where dirtected and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified and directed by the Engg-in-Charge. |
| 44 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation filling & mass concrete complete all as specified and directed by the Engg-in-Charge. |
| 45 | M&L for Machine pressed precast concrete interlocking paver block glossy finish any shape and size with grey cement & no pigment confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade complete all as specified and directed by the Engg-in-Charge. |
| 46 | M&L Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by the Engg-in-Charge. |
| 47 | S&F in repairs 25mm dia fancy aluminium Alloy CP curtain rod with bracket and screw with neccessary all fittings complete all as specified and directed by the Engg-in-Charge. |
| 48 | S&F factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed by the Engg-in-Charge. |
| 49 | Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each without taking off shutters from the frames all as specified and directed. |
| 50 | Taking down chowkhats or frames not exc. 1.5 sq. m each all as specified and directed. |
| 51 | S&F second class soft wood (KAIL) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by the Engg-in-Charge. |
| 52 | S&F sheet glass 3.00 mm thick ordinary quality, and glazing with oil putty in square nexc. 0.50Sqm each pane complete all as specified and directed by the Engg-in-Charge. |
| 53 | S&F anodised aluminium barrel tower bolt extruded sections 100 mm size complete all as specified and directed by the Engg-in-Charge. |
| 54 | S&F 9mm thick prelaminated particle board, interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails to timber frame work in ceiling or sloping complete all as specified and directed by the Engg-in-Charge. |
| 55 | S&F second class softwood fillets square, rectangular or triangular in section sectional area not exceeding 3 sqcm , clean sawn, secured with nails or brads bullnosed, splayed, chamfered or rounded on one edge or face as in cover fillets complete all as specified and directed by the Engg-in-Charge. |
| 56 | S&F second class softwood moulding as in cornices, picture rails and the like sectional area not exceeding 6 Sqcm fixed with nails complete all as specified and directed by the Engg-in-Charge. |
| 57 | M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer complete all as specified and directed by the Engg-in-Charge. |
| 58 | S&F Solid PVC Wall Lining consisting of 5mm thick wood grain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed by the Engg-in-Charge. |
| 59 | S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed by the Engg-in-Charge. |
| 60 | Dismantling timber scantlings 40 sqcm and over in section, in any position in framed work in partition complete all as specified and directed by the Engg-in-Charge. |
| 61 | Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed by the Engg-in-Charge. |
| 62 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing with Extra for Powder Coating (minimum thickness of powder coating 50micron) complete all as specified and directed by the Engg-in-Charge. |
| 63 | M&L for coloured non-skid ceramic tiles 7 to 8mm thick ( square / rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc set and set and jointed in neat cement slurry and pointed in white or coloured cement to match the work including 15 thick screed bed in CM (1:6) complete all as specified and directed by the Engg-in-Charge. |
| 64 | M&L PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed by the Engg-in-Charge. |
| 65 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework complete all as specified and directed by the Engg-in-Charge. |
| 66 | M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified and directed by the Engg-in-Charge. |
| 67 | M&L for stone masonry walling of random rubble,uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed by the Engg-in-Charge. |
| 68 | Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and directed by the Engg-in-Charge. |
| 69 | M&L for precast cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates as in lintels, landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 70 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, ending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engg-in-Charge. |
| 71 | Demolition of precast concrete articles and precast concrete block walling including all quoins, arches, pillars, etc built in cement mortar of any description not other specifically provided for etc complete all as specified and directed by the Engg-in-Charge. |
| 72 | M&L for Precast cement concrete type C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6) complete all as specified and directed by the Engg-in-Charge. |
| 73 | M&L rendering 15mm thick cement plaster in cement mortor (1:4) finished even & fair without using extra cement on brick/concrete surfaces complete all as specified and directed by the Engg-in-Charge. |
| 74 | Taking down PVC pipe, eaves and gutters (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by the Engg-in-Charge. |
| 75 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 76 | S&F in repair 15mm bore PVC connection 600mm long both ends screwed with brass cap complete all as specified and directed by the Engg-in-Charge. |
| 77 | S&F in repair 15mm bore bib taps standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge. |
| 78 | S&F in repair 15mm bore dia angle valves of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge. |
| 79 | S&F in repair 15mm bore Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-110gms) complete all as specified and directed by the Engg-in-Charge. |
| 80 | S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by the Engg-in-Charge. |
| 81 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20mm dia pipes complete all as specified and directed. |
| 82 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 25 mm dia pipes complete all as specified and directed by the Engg-in-Charge. |
| 83 | S&F 20mm outer diameter 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UVstabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by the Engg-in-Charge. |
| 84 | All as per item ser No 83 above but 25mm outer diameter complete all as specified and directed by the Engg-in-Charge. |
| 85 | S&F in repairs 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by the Engg-in-Charge. |
| 86 | S&F in repairs vitreous china wash hand basin (flat black) white of size 550x400mm with pedestal excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size complete all as specified and directed by the Engg-in-Charge. |
| 87 | S&F in repairs 32mm dia Waste coupling of CP brass for WHB including waste pipe complete all as specified and directed by the Engg-in-Charge. |
| 88 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) with Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device to be approved by Engr in Charge, complete all as specified and directed by the Engg-in-Charge. |
| 89 | S&F in repairs 10ltrs capacity PVC valveless syphonic action type low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed by the Engg-in-Charge. |
| 90 | S&F in repair 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by the Engg-in-Charge. |
| 91 | S&F 110mm bore PVC (SWR) bends with oval access door any radius complete all as specified and directed by the Engg-in-Charge. |
| 92 | S&F in repair 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed by the Engg-in-Charge. |
| 93 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 94 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed by the Engg-in-Charge. |
| 95 | M&L for two coats of Oil bound distemper on old plastered surfaces of walls including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 96 | M&L for preparing old wooden surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed by the Engg-in-Charge. |
| 97 | S&F in repairs stainless steel squatting pan of pattern “long pan”, size 580x440mm with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge. |
| 98 | Dismantling PVC water tanks of capacity exc 500 but n exc 1000 ltr and removing to store complete all as specified and directed by the Engg-in-Charge. |
| 99 | S&F 1000ltr capacity rotationally moulded polythene water storage tanks (cylindrical vertical with closed top) multilayers layers of approved make hoisted & fixed at position complete all as specified and directed by the Engg-in-Charge. |
| 100 | M&L for Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 101 | M&L for Point wiring for light/fan with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point controlled by one switch. |
| 102 | All as per Srl item No. 101 here in before but for one 3 pin 5 Amps socket outlet on same board. |
| 103 | All as per Srl item No 101 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 104 | All as per Srl item No 101 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 105 | S&F Switch piano flush type 5 Amps, single pole one way. |
| 106 | S&F Switch socket combination 2 in 1, and 3 and 2 pin, 5Amps flush type. |
| 107 | S&F Switch socket combination 2 in 1, 5 and 15Amps flush type. |
| 108 | S&F Socket Outlet 2 in 1, 5 Amp flush type |
| 109 | S&F of ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed. |
| 110 | S&F in repair LED lights fitting, surface mounting general purpose ultra slim economical LED batten of 1x18W, lumen out put 100lm/wattt, CCT:6500K/3000K, PF>0.9, in extruded PC housing and round/square shaped diffuser including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by the Engg-in-Charge. |
| 111 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm including making arrangement for fixing complete all as specified and directed by the Engg-in-Charge. |
| 112 | S&F in repair LED flood light 70watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete including connecting to ceiling rose with suitable size of cable complete all as specified and directed by the Engg-in-Charge. |
| 113 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 12way with 200Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 114 | S&F in replacement 240V 10KA C curve MCB SPN 40 to 63Amp in the MCB DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 115 | S&F in replacement 240V 10 KA C curve MCB SP 6 to 32Amp in the MCB DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 116 | M&L for submain wiring comprising single core, 2 Runs of 10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 2mm thick PVC Casing Caping ISI Marked(heavy duty) and its fittings on surface/recessed complete including 1X10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS including taking down old UNSV submain wiring and making good the disturbed surface complete all as specified and directed by Engr-In-charge.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 117 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing.Notes: (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate,(ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same. |
| 118 | S&F in replacement 1100volts grade heavy duty 16Sqmm 2core flat cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by the Engg-in-Charge. |
| 119 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 16way with 200Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 120 | Supply, installation, commisioning and testing in replacement of factory made (CPRI approved) LT panel board of suitable size out door type (single dore) 415 volts,dust proof, vermin proof, made out of CRCA sheet 3.15 mm thick duly compartmentalised inside panel with 2mm thick CRCA sheet, to accommodate the incoming and outgoing, and having provision for front and rear side opening with rubber beading and brass cable glands for each cable to make it weather and vermin proof. single door hinged type , both side openable, air fins for ventilation, panel shall be mounted on angle of size (40x40x6 mm) & duly spray painted with seven tank process internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs of suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20mm graded stone aggregate) or as manufacturer instruction and including notice board & danger plate complete with all connection incoming/outgoing complete all as specified and as directed by Engr-in-Charge. Comprising of following accessories :- INCOMING (a) MCCB 4 pole 125 amps , 415 volt of breaking capacity not less than 25 KA(lcs=100% of lcu) with fixed TM range - 01 No for incoming. (b) Aluminium bus bar 200 Amps current rating duly sleeve insulated for set of 3 phase, 4 wire system -01 Set. OUTGOING (a) MCB DP 63 Amps, 230 Volts breaking capacity not less than 10 KA C curve - 06 Nos. (b) Multifunction digtal VAF-PF meter of suitable capacity, with inbuilt selector switch - 01 SET. (c) LED indicator Lamps R,Y,B - 01 Set. |
| 121 | S&F GI tubing light grade 40mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc complete all as specified and directed by the Engg-in-Charge. |
| 122 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of hard / dense soil for taking out cable & laying of cable complete all as specified and directed by the Engg-in-Charge. |
| 123 | Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by the Engg-in-Charge. |
| 124 | Returning filling, including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified and directed by the Engg-in-Charge. |
| 125 | Supply & laying or fixing and testing of DWC (Double Wall Corrugated) duct pipe (HDPE) of size 63x50mm laid in trench/ducts/under roads/under hard standing/along poles complete all as specified and directed by the Engg-in-Charge. |
| 126 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized strip or wire armoured, electric power cables (heavy duty) 1100volts grade with stranded aluminium conductor of size 16sqmm 2core complete all as specified and directed by the Engg-in-Charge. |
| 127 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq. mm 3.5 core complete all as specified and directed by the Engg-in-Charge. |
| 128 | S&F Bell push, flush type, 5 Amp complete all as specified and directed by the Engg-in-Charge. |
| 129 | S&F Electronic Ding Dong Bell, AC 240 volts single pole, complete all as specified and directed by the Engg-in-Charge. |
| 130 | S&F Modular socket 6A-2/3 pin combined 2 module. |
| 131 | S&F Modular socket 6A/16 A -2/3 pin combined 2 module. |
| 132 | S&F Modular switch 1 way 6A, 1 module. Please Enable Macros to View BoQ information |
| 133 | S&F Modular switch 1 way 6A, 1 module. Please Enable Macros to View BoQ information |