| 1 | 1. PT-100 strap on type RTD for 400 NB at KGS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at KGS. ( 18 nos for KGS 1 and 2 and 18 nos for KGS 3 and 4) |
| 2 | 2. PT-100 strap on type RTD for 400 NB at KAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at KAPS ( KAPS 1 and 2 ) |
| 3 | 3. PT-100 strap on type RTD for 400 NB at NAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at NAPS |
| 4 | 4. PT-100 strap on type RTD for 400 NB at RAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at RAPS (18 nos for RAPS 3 and 4 and 18 nos for RAPS 5 and 6) |
| 5 | 5. PT-100 strap on type RTD for 500 NB at TAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 500 NB line, OD 508 mm to be supplied at TAPS (TAPS 3 and 4) |
| 6 | 6. PT-100 strap on type RTD for 600 NB at TAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 600 NB line, OD 610 mm to be supplied at TAPS (TAPS 3 and 4) |
| 7 | 7. PT-100 strap on type RTD for 300 NB at RAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 300 NB line, OD 323.84mm to be supplied at RAPS (RAPS 1 and 2) |
| 8 | 8. PT-100 strap on type RTD for 300 NB at MAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 300 NB line, OD 323.84mm to be supplied at MAPS |
| 9 | 9. Test strap on type RTD for 600 NB at TAPS | Test strap on type RTD with 6 meter MI cable and 4 meter extension cable for 600 NB line, OD 610 mm for carrying out the type tests and to be supplied at TAPS (TAPS 3 and 4) |
| 10 | 10. Pt 100 simplex area temperature RTD at KGS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at KGS ( 14 nos for KGS 1 and 2, 14 nos for KGS 3 and 4 ) |
| 11 | 11. Pt 100 simplex area temperature RTD at KAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at KAPS (KAPS 1 and 2) |
| 12 | 12. Pt 100 simplex area temperature RTD at NAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at NAPS |
| 13 | 13. Pt 100 simplex area temperature RTD at RAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at RAPS ( 7 nos for RAPS 1 and 2, 14 nos for RAPS 3 and 4, 14nos for RAPS 5 and 6 ) |
| 14 | 14. Pt 100 simplex area temperature RTD at TAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at TAPS (TAPS 3 and 4) |
| 15 | 15. Pt 100 simplex area temperature RTD at MAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at MAPS (MAPS 1 and 2) |
| 16 | 16. Pt 100 simplex area temperature RTDs at KGS | Test Pt 100 simplex area temperature RTDs with MI cable and 4 meter extension cable for carrying out the type tests and to be supplied at KGS |