| 1 | Earthwork in excavation by mechanical means (hydraulic excavator) / manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. |
| 2 | All kinds of soil |
| 3 | Earthwork in excavation by mechanical means (hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : |
| 4 | All kinds of soil |
| 5 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 6 | Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building. |
| 7 | Pre-construction |
| 8 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 9 | All works upto plinth level |
| 10 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 11 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 12 | Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. |
| 13 | moorum |
| 14 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 15 | Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 16 | Providing andlaying inposition (1:11/2:3) Reinforced cementconrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) |
| 17 | All works upto plinth level |
| 18 | In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level |
| 19 | In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level |
| 20 | Centering and shuttering including struttings, propping etc. and removal of formwork for : |
| 21 | Foundations, footings, bases for columns and mass concrete |
| 22 | vertical surfaces such as retaining walls , return walls, walls (any thk) including attached pilasters, buttresses, plinth and string courses, fillets, etc. |
| 23 | Columns, Pillars ,piers,abutments, posts and strut, square, rectangular, polygon in plan. etc. |
| 24 | Centering & shuttering including Strutting, Propping & removal of forms for : |
| 25 | Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth |
| 26 | Suspended floors, roofs landings, shelves & their supports |
| 27 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 28 | Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. |
| 29 | Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws. |
| 30 | Plain grill |
| 31 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section. |
| 32 | Figured glass |
| 33 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Adjustable louvered windows. |
| 34 | Figured glass |
| 35 | FRP (Fiber Reinforced Polymer) Frames : Manufacture, Supply and Installation (with anchor fastener) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) Frame of cross section as per options below with right angle joint and FRP (Fiber Reinforced Polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). The core of frame would be filled with seasoned wood as infill material. The slot of frame for door resting will be of suitable width so as to take specified thickness door.. The frame will be water proof as well as mild acid/ alkali resistant manufactured in an ISO 9001- 2015 certified company. |
| 36 | 5” x 2 ½ “ |
| 37 | Wood Finish Foam Core FRP (Fiber Reinforced Polymer) Door Shutter Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness asper options below by using tray system, with seasoned hard wood, moisture less than 17%, wood styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) along with printed matt havingwoodentextures,usedalongwith UVResistantresinto givethe clear wooden texture on the door. The core of shutter will be filled as specified(ExpandedPolystyreneFoam/Polyurethane Foam(EPS/PU) Foam) The shutter to be water proof as well as mild acid / alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) Technology in line with IS 13034 1990 test Standard in an ISO 9001 – 2015 certified factory. |
| 38 | Accessories: i. S. S. Hinges 4” - 3 No ii. S. S. Latch - 1 No iii. Tower Bolt 5” - 2 Nos iv. Handle 5” - 2 Nos Shutter Thickness: b. 35mm |
| 39 | Providing and fixing M.S. tower bolts (barrel type) with necessary screws etc. complete |
| 40 | 200 x 10 mm |
| 41 | Providing and fixing M.S. door latch with screws etc. complete |
| 42 | 300 x 20 x 6 mm |
| 43 | Providing and fixing M.S. handles with necessary screws etc. complete. |
| 44 | 125 mm |
| 45 | Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embeded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size. |
| 46 | 40 x 3 mm flat iron hold fast, 15 cm long |
| 47 | Providing and fixing bright finished brass butt hinges with necessary screws etc complete |
| 48 | 125 x 70 x 4 mm (ordinary type) |
| 49 | Providing and fixing 150 mm. bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete. |
| 50 | Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-incharge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete |
| 51 | Wall Ceramic Glazed Tiles : 200 x 300 |
| 52 | Providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete |
| 53 | Dark Shades |
| 54 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 55 | Providing and fixing Colouron Plus galvulium roofing Sheets of 0.5mm thick double ribbed trapezoidal profile coated 1080mm with cover width of 1020mm including all the accessories (JSW or equivalent make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 56 | Add for providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth upto 610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 57 | Providing and fixing 15cm wide 45cm overall semi-circular plain G.I. sheets gutter with iron brackets 40 x 3 mm bolts nuts and washers etc., including making necessary connection with rain water pipe complete as per design. |
| 58 | 0.63 mm thick sheet |
| 59 | Providing & fixing 20 mm caves barge boards 2nd class matti wood |
| 60 | 12mm cement plaster 1: 3 (1 cement ; 3 coarse sand) finished with a floating coat of neat cement. |
| 61 | 6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand) |
| 62 | 12mm cement plaster 1:3 (1 cement : 3 fine sand) |
| 63 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 64 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 65 | Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 66 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 67 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. |
| 68 | Providing and fixing in position S.S. hand rail in main stair case, and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials, etc. complete. |
| 69 | Providing and laying indesign& pattern factory made chamfered edge Cement Concrete paver blocks ( C. C. paver blocks) of M35/M40 strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with river/manufactured sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer’s specifications & direction of Engineer. |
| 70 | 80 mm thick with Red/ Black colour (M40 grade) |
| 71 | Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. long complete as per standard design |
| 72 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. |
| 73 | Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 74 | Providing and fixing white vitereous china pedestal type (Europen type) water closet with seat as lid, whth C.I. brass hinges and rubber fitings 15 lts white vitreous china low level flushing cistern with fittings as brackets 40 mm white precelain 3enameled flush bad, 25 mm overflow pipe with specials and mosquito proof coupling of approved municipal design complete, including cutting and making good the walls and floors where required. |
| 75 | W.C. pan with white plastic seat and lid |
| 76 | Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. |
| 77 | Flat back wash basin size 630x 450mm with a single 15 mm C.P. brass pillar taps. |
| 78 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. |
| 79 | SCH-80(blue)/(white) : 25mm outer dia. |
| 80 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work Exposed on wall. |
| 81 | SCH-80(blue)/(white) : 20mm outer dia. |
| 82 | Providing and fixing brass bib cock (heavy) of approved quality : |
| 83 | 20 mm nominal bore |
| 84 | Providing and fixing brass stop cock (heavy) of approved quality : |
| 85 | 20 mm nominal bore |
| 86 | Providing and fixing ball valve (brass) of approved quality : |
| 87 | High pressure with P.V.C. floats: 20 mm nominal bore |
| 88 | Providing and fixing non-return valve of approved quality : |
| 89 | 32 mm nominal bore |
| 90 | Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design : |
| 91 | 150 x 100 mm size –P or S type |
| 92 | Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door : |
| 93 | 110 mm dia |
| 94 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. |
| 95 | 110 mm dia |
| 96 | Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door: |
| 97 | 110 mm dia. |
| 98 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: |
| 99 | 110 mm dia |
| 100 | Providing and fixing U.P.V.C. pipe clips (approved make ) for S.W.R. pipes : |
| 101 | 110 mm dia |
| 102 | Providing and fixing R.P.V.C. vent cowl: |
| 103 | 110 mm dia |
| 104 | Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996. |
| 105 | 200 lit .capacity |
| 106 | Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers. |
| 107 | Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws |
| 108 | 600 x 20 mm size |
| 109 | Providing & fixing liquid soap container with C. P. brass lid and brackets fixed to wooden cleats with C. P. brass screws |
| 110 | Plastic container |
| 111 | Supplying and fixing electrical Conduits and Fixtures Please Enable Macros to View BoQ information |