| 1 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. |
| 2 | Hard rock where blasting prohibited |
| 3 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 4 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 5 | All works upto plinth level |
| 6 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 7 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 8 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 9 | Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 10 | Centering and shuttering including struttings, propping etc. and removal of formwork for : |
| 11 | Foundations, footings, bases for columns and mass concrete |
| 12 | Columns, Pillars ,piers,abutments, posts and strut, square, rectangular, polygon in plan. etc. |
| 13 | Providing and laying inposition (1:11/2:3) Reinforced cementconrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) |
| 14 | All works upto plinth level |
| 15 | In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level |
| 16 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 17 | Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. |
| 18 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section. |
| 19 | Figured glass |
| 20 | Providing and laying 100 mm thick factory made cement concrete interlocking paver block of M 50 grade made by heavy duty block making machine with strong vibratory compaction and of approved size and design / shape laid in 50 mm thick compacted be of course sand. filling the joints with course sand, etc. all complete as per the direction of Engineer. |
| 21 | Cuddappah stone slab machine cut flooring over 20mm (average) thickness of cement mortar 1:4 (1 cement : 4 coarse sand laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete - 25 mm thick. |
| 22 | Providing and fixing Granite stone slabs (mirror polished) 18mm thick in risers of steps, skirting, dado and pillars laid on cement paste and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 23 | Cherry Red |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 25 | Providing and fixing Colouron Plus galvulium roofing Sheets of 0.5mm thick double ribbed trapezoidal profile coated 1080mm with cover width of 1020mm including all the accessories (JSW or equivalent make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 26 | Add for providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth upto 610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 27 | Providing and fixing Prince or equivalent make PVC SWR half round eaves gutter with bolts, nuts and flat iron brackets 40 x 3 mm size complete. |
| 28 | 250 mm nominal size |
| 29 | Providing & fixing 20 mm caves barge boards 2nd class matti wood |
| 30 | 12mm cement plaster 1: 3 (1 cement ; 3 coarse sand) finished with a floating coat of neat cement. |
| 31 | 12mm cement plaster 1:3 (1 cement : 3 fine sand) |
| 32 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 33 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 34 | Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 35 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 36 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade. |
| 37 | Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. long complete as per standard design |
| 38 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. |
| 39 | Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 40 | Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design : |
| 41 | 150 x 100 mm size –P or S type |
| 42 | Providing and fixing white vitereous china pedestal type (Europen type) water closet with seat as lid, whth C.I. brass hinges and rubber fitings 15 lts white vitreous china low level flushing cistern with fittings as brackets 40 mm white precelain 3enameled flush bad, 25 mm overflow pipe with specials and mosquito proof coupling of approved municipal design complete, including cutting and making good the walls and floors where required. |
| 43 | W.C. pan with white plastic seat and lid |
| 44 | Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. |
| 45 | Flat back wash basin size 630x 450mm with a single 15 mm C.P. brass pillar taps. |
| 46 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. |
| 47 | SCH-80(blue)/(white) : 25mm outer dia. |
| 48 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work Exposed on wall. |
| 49 | SCH-80(blue)/(white) : 20mm outer dia. |
| 50 | Providing and fixing brass bib cock (heavy) of approved quality : |
| 51 | 20 mm nominal bore |
| 52 | Providing and fixing brass stop cock (heavy) of approved quality : |
| 53 | 20 mm nominal bore |
| 54 | Providing and fixing ball valve (brass) of approved quality : |
| 55 | High pressure with P.V.C. floats : 20 mm nominal bore |
| 56 | Providing and fixing non-return valve of approved quality : |
| 57 | 32 mm nominal bore |
| 58 | Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door : |
| 59 | 110 mm dia |
| 60 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. |
| 61 | 110 mm dia |
| 62 | Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door: |
| 63 | 110 mm dia. |
| 64 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: |
| 65 | 110 mm dia |
| 66 | Providing and fixing U.P.V.C. pipe clips (approved make ) for S.W.R. pipes : |
| 67 | 110 mm dia |
| 68 | Providing and fixing R.P.V.C. vent cowl: |
| 69 | 110 mm dia |
| 70 | Providing and placing on terrace roof offloor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996. |
| 71 | 500 lit. capacity |
| 72 | Providing and fixing prefabricated compound gate of G.I.pipes 40 –50 mm dia (medium) with 12mm M.S. square bars of G.I. pipes grill work as per drawing including providing & fixing locking arrangements, pintals, hold fast embedded in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 granitic or basaltic aggreate 20mm nominal size) including applying priming coat with ready mixed red lead paint and painting 2 or more coats with superior ready mixed paint of approved brand and manufacture in all shades as per direction complete. |
| 73 | Supplying and fixing electrical Conduits and Fixtures Please Enable Macros to View BoQ information |