| 1 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. |
| 2 | a) All kinds of soil |
| 3 | c) Hard rock where blasting prohibited |
| 4 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 5 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 6 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 7 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in Superstrcuture from floor I level upto floor V level. |
| 8 | Providing & laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded granitic or basaltic stone aggrt. 40 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 9 | a) All works upto plinth level |
| 10 | Making plinth protection 50mm thick of Cement Concrete 1:3:6 (1cement : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry laterite aggregate 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 11 | Centering & shuttering including Strutting, Propping & removal of forms for : |
| 12 | i) Foundations, Footings, Bases for columns |
| 13 | iii) Columns, Piers, Pillars, Abutments, Posts and struts (square rectangle polygon in plan) |
| 14 | iv) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, bressumers and Lintels plinth beams not exceeding 1m in depth |
| 15 | xiii) Suspended floors, roofs landings, shelves & their supports |
| 16 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 17 | Providing Pre-cast concrete jali 1:2:4 (1 : 2 coarse sand: 4 stone aggreate 6mm nominal size) reinforced with 1.6mm dia mild steel wire including centering and shuttering, roughening, cleaning, fixing and finishing in mortar 1:3 (1 : 3 fine snad) all complete excluding plastering of the jambs, sills and soffits. |
| 18 | iii) 25mm thick |
| 19 | Providing and laying in position machine batched concrete (BMC), machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering , shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer-in-charge. M25 grade of reinforced cement conrete by using 410kg of cement per cu.m. of concrete. All works upto floor V level. |
| 20 | Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon. |
| 21 | b) Second class Indian teak wood |
| 22 | Providing and fixing 44 mm. thick panelled, glazed or panelled and glazed shtters for doors, windows and clestory windows including anoodized aluminium butt hinges with necessary screws. |
| 23 | a) Second class Indian teak wood |
| 24 | Providing and fixing flush doors shutters commercial type, core of block board construction with frame of first class hard wood and well matched commercial ply veneering and vertical grains or cross bands and face veneers on the both other faces of shutters. |
| 25 | a) 40 mm thick including anodized aluminum butt hinges with necessary screws: |
| 26 | Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embeded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size. |
| 27 | a) 40 x 3 mm flat iron hold fast 40 cm long |
| 28 | Providing and fixing bright finished brass butt hinges with necessary screws etc complete |
| 29 | a) 125 x 70 x 4 mm (ordinary type) |
| 30 | Providing and fixing bright finished brass tower bolts (barrel type) with screws etc. complete |
| 31 | a) 250 x 10 mm |
| 32 | Providing and fixing bright finished brass handles with necessary screws etc complete |
| 33 | a) 125 mm |
| 34 | Providing and fixing bright finished brass door latch with necessary screws etc complete |
| 35 | a) 300x 16 x 5 mm |
| 36 | Providing and fixing 150 mm. bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete. |
| 37 | Standard Wood Core Door Shutter with Single Colour : Manufacture, Supply and Installation(including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness as per options below by using tray system with seasoned hard wood, moisture less than 17%, woodstylesforToprailandlockrails.FRP(Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of400/450centipoisespersecond(cps).Thecore of Shutter will be filled with MR2nd grade Block Board. The shutter to be water proof as well as mild acid / alkali resistant manufactured using RVTIFAC(RVEngineeringCollege,Bangalore& Technology Information Forecasting & Assessment Council) technology in line withIS 13034 1990 test Standard in an ISO 9001 –2015 certifiedfactory. |
| 38 | Accessories: i. S. S. Hinges 4” - 3 No ii. S. S. Latch - 1 No iii. Tower Bolt 5” - 2 Nos iv. Handle 5” - 2 Nos Shutter Thickness: b. 32mm |
| 39 | TWO TRACK SLIDING WINDOW (Heavy):- |
| 40 | Providing and fixing Two Track sliding window in heavy sections made out of 104mm x 51 mm x 2.5 mm Upvc multi cavity track section & shutter made out of 45mm x54mm x 2.5mm Upvc multi cavity section welded in corners with Glass beading & EPDM Gasket & 4mm clear glass with lock & rollers. The average weight of Two Track Sliding window (Heavy) is 16.75 kg per sq mtr. These Upvc sections are tested by using BS 2782 & DIN 53459 test methods. |
| 41 | Providing and fixing M.S. fan clamp type 1or II of 16 mm dia M.S. bar bent to shape with hooke ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. |
| 42 | Providing and fixing in position S.S. hand rail in main stair case, and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials, etc. complete. |
| 43 | Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws. |
| 44 | Plain grill |
| 45 | Providing and and laying vitrified floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete |
| 46 | a) 600x 600 mm Dark Shades |
| 47 | Providing and laying in design & pattern factory made chamfered edge Cement Concrete paver blocks ( C. C. paver blocks) of M35 strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with river/manufactured sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer’s specifications & direction of Engineer. |
| 48 | f) 80 mm thick with Yellow/ Orange/ Earth color (M40 grade) |
| 49 | Providing & laying mangalore tiles roof covering over M25 grade Precast Cement Concrete Rafters placed @ 60cm C/C apart fixed with adhesive such as Bal endura, Sika etc. over sloping roof slabs & precast concrete Battens includiing all material, labour, tools & plants all complete.(Cost includes mangalore tiles, rafters& battens) |
| 50 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 51 | 6mm cement plaster to ceilling 1:3 (1 cement : 3 fine sand) |
| 52 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 53 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 54 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 55 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 56 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 57 | Melamine polishing on wood work (one or more coat) |
| 58 | a) Glossy |
| 59 | Providing and fixing white vitereous china pedestal type (Europen type) water closet with seat as lid, whth C.I. brass hinges and rubber fitings 15 lts white vitreous china low level flushing cistern with fittings as brackets 40 mm white precelain 3enameled flush bad, 25 mm overflow pipe with specials and mosquito proof coupling of approved municipal design complete, including cutting and making good the walls and floors where required. |
| 60 | W.C. pan with white plastic seat and lid |
| 61 | Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. |
| 62 | b) Flat back wash basin size 630x 450mm with a single 15 mm C.P. brass pillar taps. |
| 63 | Providing and fixing brass bib cock (heavy) of approved quality : |
| 64 | a) 15 mm nominal bore |
| 65 | Providing and fixing brass stop cock (heavy) of approved quality : |
| 66 | 15 mm nominal bore |
| 67 | 20 mm nominal bore |
| 68 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. |
| 69 | d) Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 70 | Making soak pit. 2.5 m dia 3 m deep with 45x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter, 1.8 m long complete filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 40 mm and down gauge as per standard design. |
| 71 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: |
| 72 | a) 110 mm dia |
| 73 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. |
| 74 | a) 110 mm dia |
| 75 | Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door : |
| 76 | a) 100 mm dia |
| 77 | Providing and fixing NICKEL chrome plated copper alloy Fancy Pillar Cock rocket type Jaquar make or equivalent. Confirming to IS 8931;1993 |
| 78 | a) 15mm nominal bore |
| 79 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. |
| 80 | c) 25 mm dia nominal outer dia pipes. |
| 81 | d) 32 mm dia nominal outer dia pipes. |
| 82 | Providing & fixing bevelled edge mirror of superior glass (5mm thk) of approved Quality, shape & size complete with CP brass screws and washers, Cleats, CP studs etc Complete. |
| 83 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. I SCH-40(blue)/(white) |
| 84 | c) 32mm outer dia. |
| 85 | d) 40mm outer dia. |
| 86 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/Cuddapah stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 87 | Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building. |
| 88 | a) Pre- construction |
| 89 | Supplying and fixing electrical Conduits and Fixtures Please Enable Macros to View BoQ information |