| 1 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 2 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 3 | All works upto plinth level |
| 4 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. |
| 5 | Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 6 | Centering & shuttering including Strutting, Propping & removal of forms for : |
| 7 | Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth |
| 8 | Suspended floors, roofs landings, shelves & their supports |
| 9 | Providing and laying inposition (1:11/2:3) Reinforced cementconrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) |
| 10 | In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level |
| 11 | Reinforced cement concrete work 1:1½:3 (1 cement: 1½ coarse sand: 3 granitic or basaltic stone aggreate 20mm nominal size excluding plastering and cost of centering, shuttering & reinforcement, in sloping or battering surface (slabs, beams, louvers, etc) |
| 12 | Where inclination to the horizontal exceeds 30° |
| 13 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 14 | Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. |
| 15 | Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws. |
| 16 | Plain grill |
| 17 | Providing and laying 100 mm thick factory made cement concrete interlocking paver block of M 50 grade made by heavy duty block making machine with strong vibratory compaction and of approved size and design / shape laid in 50 mm thick compacted be of course sand. filling the joints with course sand, etc. all complete as per the direction of Engineer. |
| 18 | Providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete |
| 19 | Dark Shades |
| 20 | Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) |
| 21 | 20 mm thick |
| 22 | 6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand) |
| 23 | 12mm cement plaster 1:3 (1 cement : 3 fine sand) |
| 24 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 25 | Supplying and fixing electrical Conduits and Fixtures Please Enable Macros to View BoQ information |