| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 4 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed. |
| 5 | Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 6 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed. |
| 7 | Demolition of cement concrete of (unreinforced) any description and any position not otherwise specifically provided for and removal of rubbish from the site complete all as specified and as directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and segregating serviceable materials and keeping for reuse at site and removing unserviceable materials from site of work complete all as specified and as directed. |
| 9 | Material and labour for plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in roof kerb or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 10 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 11 | Supply and fixing steel work in tubular trusses i.e truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 etc complete all as specified and as directed. |
| 12 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 13 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 14 | Supply and fixing 4mm thick HSPC(High Pressure Steam Cured) board as in false ceiling with powder coated GI/aluminium snap grid/section of size 600mm x 600mm fixed to wall hanging from soffits/trusses using adjustable supporting hanger comprising of 4mm dia MS rod or wire ‘J’ type hook, nuts, bolts, holding down clips with GI/aluminium section of size 36.5mm x 25mm x 1.4mm (main tee) and 23.5mm x 26.4mm x 1.4mm (cross tee) and wall angle of size 25mm x 25mm x 1.4mm complete all as specified and as directed. |
| 15 | Material and labour for non skid ceramic coloured tiles (Premium Quality) 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 16 | Material and labour for glazed ceramic coloured tiles (Premium Quality) of size 300x200x7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match with the shade of tiles laid over and including 10mm thick cement plaster in CM (1:4) complete all as specified and as directed. |
| 17 | Materials and labour for 15 mm thick rendering on brick work in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 18 | Materials and labour for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) with using water proofing coumpound and as per manufacturer specification and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.Note : WPC will be measured and paid separately. |
| 19 | Materials and labour for 5 mm thick rendering on concrete surfaces in ceiling in cement mortar (1:3) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 20 | Supply only liquid integral water proofing compound conforming to IS-2645 complete all as specified and directed. |
| 21 | Taking down tar felt with cement screed bed from roof surface and removing the same to a distance exceeding 50m and not exceeding 100m complete all as specified and as directed. |
| 22 | Materials and labour for 15 mm thick screed bed on concrete surface in cement mortar (1:4) with using water proofing coumpound and as per manufacturer specification and finished the surfaces fair and even complete all as specified and as directed.Note : WPC will be measured and paid separately. |
| 23 | Material and labour for water proofing treatment to roof slab & sunken portion with APP modified polymeric membrane, centre core 100 micron HMHDPE, outer film 20 micron each, having weight not less than 3 Kg/sqm with 100 mm overlap laid as per manufacturer’s instructions complete all as specified and directed by Engineer-in-Charge with following courses of descriptions below:-(a) Applying evenly a coat of bituminous primer confirming to IS-3384-1965 @ 0.40 Kg/Sqm on prepared surface till the surface is properly impregnated.(b) Second coat of bonding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 Kg per Sqm.(c) Third course i.e. laying of APP modified membrane described here-in-before with 100 mm overlap in longitudinal direction and 100 mm in transverse direction all joints and changes in all directions should be curved with cement mortar (1:3) mixed with SBR (Styrene Butadine Rubber) latex @ 200 ml per bag of cement and curved well before laying the membrane.(d) Fourth coat bonding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 Kg per Sqm. |
| 24 | Material and labour for water proofing treatment to RCC roof slab incl parapet comprising with the following course of treatment/specifications from bottom to top :- (a) Applying bituminous primer @ 200-300 gm per Sqm over plastered surfaces of roof including parapet surfaces. (b) One layer of APP based polymeric membrane of approved manufacturer, 3mm thick, weight not less than 3.60 kgs per sqm, reinforced with non woven polyester fabric or weight not less than 150 grm per sqm. Polymeric membrane shall taken to a height 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note: (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100mm and 75mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instructions. (c) Applying two coats of bituminous aluminum paint on top of APP membrane. |
| 25 | Materials and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 26 | Materials and labour for preparation of newly plastered surfaces of wall and applying two coats of acrylic washable distemper over a coat of primer over and including 1mm thick wall care putty complete all as specified and as directed. |
| 27 | Material and labour for applying two coats of cement base paint over a coat of alkali resistant primer including preparation of newly plastered surfaces of wall complete all as specified and as directed. |
| 28 | Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 29 | Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 30 | Supply and fix 20mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd. |
| 31 | Supply and fix 15mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd. |
| 32 | Supply and fixing as in replacement 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with suitable size of MS flat iron clamp complete all as specified and as directed. |
| 33 | Supply and fixing as in replacement 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with suitable size of MS flat iron clamp complete all as specified and as directed. |
| 34 | Supply and fixing 110 mm bore PVC (SWR) bends any radius with oval access door complete all as specified and directed. |
| 35 | Supply and fixing 75 mm bore PVC (SWR) bends any radius with oval access door complete all as specified and directed. |
| 36 | Supply and fixing 110mm bore PVC (SWR) junction single, (Single T) equal or unequal, with oval access door complete all as specified and as directed. |
| 37 | Supply and fixing 75mm bore PVC (SWR) junction single, (Single T) equal or unequal, with oval access door complete all as specified and as directed. |
| 38 | Supply and fixing 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 39 | Supply and fixing 75 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 40 | Supply and fixing 125/110 mm dia, PVC (SWR) gully trap, including jointing with solvent cement complete all as specified and as directed. |
| 41 | Supply, hoisting and fixing in proper position ISI marked multi-layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), of capacity 1000 litres with and including 20mm bore PTMT float and ball valve set including providing necessary connections after demolition existing PVC tank complete all as specified and as directed. |
| 42 | Supply, hoisting and fixing in proper position ISI marked multi-layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), of capacity 500 litres with and including 20mm bore PTMT float and ball valve set including providing necessary connections after demolition existing PVC tank complete all as specified and as directed. Please Enable Macros to View BoQ information |