Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | ENTRANCE GATEEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.From 0.00m To 1.50 mtr |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.From 1.50m To 3.0 mtr :-Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 3 | Providing and laying cement concrete in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. In Foundation and floors. |
| 4 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra ement,Concrete of M-25 grade with minimum cement content of 330 kg /cum.All works upto plinth level |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra ement,Concrete of M-25 grade with minimum cement content of 330 kg /cum.All works Above plinth level |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more |
| 12 | Steel Reinforcement for R.C.C. work including straightening cutting, bending, placing in position and binding all complete in all level - TMT Bars of Grade Fe-500D or more. |
| 13 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - Exposed face machine cut and tablerubbed with rough backing. |
| 14 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 15 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 16 | Supplying, fabricating, transporting, hoisting and fixing in position good quality of approved thickness red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. |
| 17 | Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.Red sand stone |
| 18 | Supplying, fabricating, transporting, hoisting and fixing in position good quality of Red sandstone Chhatri in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 0.700M Dia 0.650 M Height OR tentative Size as approved from architect in charge |
| 19 | Supplying, fabricating, transporting, hoisting and fixing in position good quality of Red sandstone Chhatri in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 0.500 M Dia 0.750 M Height OR tentative Size as approved from architect in charge |
| 20 | Supplying, fabricating, transporting, hoisting and fixing in position good quality of Ornamental Red sandstone Jharokha in various elements for all levels, inlcuding the cost of oranmental stone work and mouldings, carvings as required, the stone of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge |
| 21 | SIGNAGE3.00M Ornamental Pole with Place Identification MS Structure Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16.2) X 0.757 X 109/107 |
| 22 | Hybrid cast aluminum Pole duly primer coated & Polyester/Polyurethane painted, including cutting, hoisting, fixing in position including welding and bolted with special shaped washers etc. complete. 3000MM height. (MR- Twinkle Lite-CYPRUS-H or as approval of architect in charge) |
| 23 | Cost for CNC work in M.S. Sheet with Logo engraved. (MR) |
| 24 | Foundation and Installation of Sign Boards complete with foundation with 18mm 600 Mm Long 4 nos foundation Bolt Foundation Size 450x450x900mm (0.182 cu.mtr) as per drawing per post. (MR) |
| 25 | MURAL WALLEarth work in excavation in foundation in ordinary soil (loam, clay or sand) including lift up to 1.5 m. & lead of 30 m. including filling, watering and ramming of excavated earth dressing of sides and ramming of bottoms filling of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth in 200 mm th. layers and getting out (removal of) the excavated surplus soil and disposal of surplus excavated soil as directed by engineer-in-charge up to a distance of 30 m from foundation trenches From 0.00m To 1.50 mtr |
| 26 | Earth work in excavation in foundation in ordinary soil (loam, clay or sand) including lift up to 1.5 m. & lead of 30 m. including filling, watering and ramming of excavated earth dressing of sides and ramming of bottoms filling of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth in 200 mm th. layers and getting out (removal of) the excavated surplus soil and disposal of surplus excavated soil as directed by engineer-in-charge up to a distance of 30 m from foundation trenches From 1.50m To 3.0 mtr :-Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 27 | Providing and laying cement concrete in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. In Foundation and floors. |
| 28 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra ement,Concrete of M-25 grade with minimum cement content of 330 kg /cum.Upto Plinth Lvl. |
| 29 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra ement,Concrete of M-25 grade with minimum cement content of 330 kg /cum.Above Plinth Lvl. |
| 30 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra ement,Concrete of M-25 grade with minimum cement content of 330 kg /cum.Upto Plinth Lvl. |
| 31 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra ement,Concrete of M-25 grade with minimum cement content of 330 kg /cum.Upto Plinth Lvl. |
| 32 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra ement,Concrete of M-25 grade with minimum cement content of 330 kg /cum.Above Plinth Lvl. |
| 33 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 34 | Steel Reinforcement for R.C.C. work including straightening cutting, bending, placing in position and binding all complete in all level - TMT Bars of Grade Fe-500D or more. |
| 35 | 12mm Cement plaster with cement mortar in proportion of 1:6 cement & coarse sand of single coat for interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm in girth and finished even and smooth. |
| 36 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 38 | Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 39 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concree |
| 40 | Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 41 | C.C.ROADEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil |
| 42 | Filling By carted earth in trenches, plinth, sides of foundation, campus etc. in layers not exceeding 20 cms in depth, consolidating each deposited layer by ramming and watering including lead upto 50 m & lift upto 1.50 m. |
| 43 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 44 | Construction of dry lean cement concrete sub base over a prepared subgrade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications,cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. |
| 45 | Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 46 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.Cement concrete prepared with batch mixing machine |
| 47 | Providing and fixing in position pre-moulded joint filler in expansion joints. |
| 48 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. |
| 49 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 50 | LANDSCAPINGSupply and stacking of Plumeria alba plant of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge. |
| 51 | Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge |
| 52 | Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 53 | Supply and stacking of Michelia champa (Golden Champa)plant of height 90-105 cm. in earthen pots of size 25 cm as per direction of the officer-incharge. |
| 54 | Supply and stacking of Polyalthia longifolia (Ashok) plant of height 150- 165 cm. in earthen pots of size 25 cm as per direction of the officer-incharge. |
| 55 | Supply and stacking of Terminalia arjuna plant of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. |
| 56 | Supply and stacking of plant Tabernaemontana coronaria (Chandni single) of height 90-105 cm,bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 57 | Supply and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plasticpots & as per direction of the officer-in-charge. . |
| 58 | TOURIST COMPLEXRemoving dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 59 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 60 | Providing and applying Artistic Paint using synthetic enamel or epoxy-based paint (Expxy) in two coats with one transparent protective clear coat (PU/Acrylic) over it, including surface preparation, priming, scaffolding, labor, tools & tackles, and finishing as per the design, pattern, and shade approved by the Architect-in-Charge. |
| 61 | DRAINAGE WORKExcavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 62 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter |
| 63 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm. dia. RCC Pipes |
| 64 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes |
| 65 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 66 | Product Type: SUBMERSIBLE DRAINAGE PUMPProduct ConfigurationPump Classification: Standard PumpComponent MaterialsVolute Material: Cast Iron FG 260Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410Seal Material: Carbon/Ceramic/NBR/S.S 304Motor SpecificationsPhase: 3Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework ConnectionFloat Switch: With Float SwitchSolids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S |
| 67 | Providing & fixing of Sandstone without Handrest and backrest with Ornamentetion engraving/embossing (size 1200mm length and 450mm and height 600 mm) including foundation & support with all necessary T&P etc all complete as per design of direction in engineer/ Architect in charge. [ Details Attached ] |
| 68 | Providing & fixing of Stainless Steel Swing Type SS Pole Hanging Dustbins, Capacity: 50 L (size 350 x 600) constructed using high-quality stainless steel with removable inner bucket. |
| 69 | EXTERNAL ELECTRIFICATIONPOLE LIGHTS Supply ,Installation ,Testing And Commissining Of Twinkle Lites Make 3000Mm Long Hybrid Decorative Pole With Casted Aluminium Base And Ripped Gi Pole Pipe With Decorative Post Top Lantern 'Concord' 1270Mm Long With Polycarbonate Diffuser In 60W Led Having Lumn Output Not Less Than 110Lmns/Watt With 10Kva Surge Prtector Designed As Per Architect In-Charge ( Make- Twinkle Lite- /-Havells/Neri/Juvaas/Orient/ Thor) |
| 70 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10.00 Sqmm 4 Core |
| 71 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25.00 Sqmm 3.5 Core |
| 72 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 70.00 Sqmm 3.5 Core |
| 73 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 74 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the followingHRC type heavy duty TPN fuse switches with fuses and instrumen chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter,instrumentfuses, current transormer etc. The board shall have suitable capacity electroytic alumininumbusbars as per IS8623 istulate with heat shrink sleevingand mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compressionglands and indicatinglamp on incomingetc. Incoming 315 Amp. TPN-1 No Outgoing 100 Amp. TPN-2 No and 63 Amp. TPN-2 Nos. |
| 75 | Supply, Installation, Testing and Commissioning of LEDRGB/RGBW flood lighting luminaire for facade lighting with Die- cast aluminium housing, powder- coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The be amangle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 VAC, 50Hz with power factor>0.9. Fixture shall be suitable to operate at anambient temperature range of-10°Cto +50° C and shall be IP65 and IK06 rated. Life time shall be atleast L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS(IS10322) and shall be complete with all necessary accessories required for proper working of fixture in cluding weatherproof connection cables, waterproof connector setc. as required. 30 W |
| 76 | Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and apable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.40 W |
| 77 | Supply and Fixing 12 Wattage Burial UNIIn Ground- Burial ip68 waterproof BBP343 LED2400/1800/WW 24W/18W 20D 100-240V (Philips/Siems/or Equivalent) |
| 78 | Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. |
| 79 | Receiving, storing, handling, shifting, installation, testing & commissioning of Voltas water cooler, including all accessories complete in all respect etc. (Make - Voltas or Equivalent) |
| 80 | G.S.T Extra as per applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail