| Sl. No. | Item Description |
| 1 | Dismantling doors,windows and clerestory windows(steelorwood) shutter including chowkhats,architrave,holdfastsetc.completeand stacking within 50 metres lead (Of area 3 sq. metres and below) |
| 2 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 3 | Providing and fixing 25 mm thick factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) |
| 4 | Providing and fixing 12mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain white color board for backing of cup boards and bathroom/kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-In- Charge. (Note: stainless steel screws shall be paid separately) |
| 5 | Providing and fixing 30 mm thick Second class teak wood glazed shutters for doors,windows and clerestory windows using 4mm thick float glass panes(weightnot lessthan10kg persqm) fixing with ISI marked M.S. pressed but thinges bright finished of required size with necessary screws. |
| 6 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side 12.45.3 inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board ( Code No. 12.45.3) |
| 7 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : Using R3 series with frame (55mm & above) x (45mm & above) & sash (55mm & above) x (65mm & above) & French (False) mullion (55mm & above) x (60mm & above). (Height upto 1.8 metre). (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Using R3 series with frame (55mm & above) x (45mm & above) & sash (55mm & above) x (65mm & above) & French (False) mullion (55mm & above) x (60mm & above). (Height upto 1.8 metre). |
| 8 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : Using R3 series with frame (55mm & above) x (45mm & above) & sash (55mm & above) x (65mm & above) & French (False) mullion (55mm & above) x (60mm & above). (Height upto 1.8 metre). (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Using R3 series with frame (55 mm & above) x (50mm & above) & sash (55 mm & above) x (85mm & above) & French (False) mullion (55 mm & above) x (60mm & above). (Height upto 2.5 metre). |
| 9 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : Using R3 series with frame (55mm & above) x (45mm & above) & sash (55mm & above) x (65mm & above) & French (False) mullion (55mm & above) x (60mm & above). (Height upto 1.8 metre). (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Using R3 series with frame (55mm & above ) x (45mm & above). (Height upto 2.5 metre) |
| 10 | Providing and fixing 30mm thick ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters |
| 11 | Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : |
| 12 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 13 | Providing and fixing 12 mm thick at all height wall panelling with phenol bonded Bamboo Mat board conforming to IS:13958-1994 including providing and fixing to frame work made of 50mm x 50mm hardwood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge. |
| 14 | 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete |
| 15 | Wiring for light point/ fanpoint/ exhaust fanpoint/ call bell pointwith1.5 sq.mm FRLSPVC insulated copper conductor single core cable insurface/ recessed medium class PVC conduit, with modular switch,modular plate, suitable GI box and earthing the point with1.5sq.mm. FRLSPVC insulated copper conductor single corec able etc as required..Group C (DSRE&M 2022 1.10.3) |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate&switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 17 | Supplying and fixing of 25mm of medium class PVC conduit along with accessories insurface/recess including junction box,cutting the wall and making good the same in case of recessed conduit asr equired |
| 18 | Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) (code 27.10) |
| 19 | Supply Installation, Testing and Commissioning of 1200mm sweep, BEE 5 Star rated, ceiling fan with Brush less Direct Current (BLDC) Motor, class of Insulation: B, 3 nos blades,30cm long down rod,2 nos canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/M/W) minimum 6.00 Air delivery minimum 210 Cum/min 350 RPM (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise-75 degree C (MAX.) INSULATION RESISTANCE MORE THAN 2 MEGA OHM. (NSI) SUITABLE FOR 230v, 50Hz. Songle phase AC supply, earthing etc. complete as required (DSR E&M 2022 19.1) |
| 20 | Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (code 27.11) |
| 21 | Wiring for circuit/ submain wiring with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(code No. 27.06) |
| 22 | Wiring for circuit/ submain wiring with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR E&M 2022 1.14.2) (code No. 27.05) |
| 23 | Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.(code No. 27.14) |
| 24 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(code No. 27.16) |
| 25 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) (code No. 27.17) |
| 26 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) (Code No. 27.19) |
| 27 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm) (Code No. 27.21 ) |
| 28 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. |
| 29 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. (CSI No. 28.40) |
| 30 | Providing and fixing 30 mm thick factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutterof required sizecomprisingofvirginpolymerof Kvalue 58-60 (SuspensionGrade), calciumcarbonate and natural fibers (wood powder/ ricehusk/wheathusk)andnontoxicadditives(maximumtoxicityindexof12 for100gms having minimum density of 650kg/cum and screw withdrawal strengthof 1800N(Face)&900N(Edge),minimum compressive strength 50N/mm2, modulus ofelasticity 850N/mm2 and resistance tospread of flame of ClassA category with property of beingtermite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum14microns thick of approved design pasted withhot melt adhesiveonboth facesof shutter and fixingwithstainlesssteel butt hingesof requiredsizewithnecessary full body threadedstarheadedcountersunk S.Sscrews, all asper directionofEngineer-In-Charge. (Note: stainlesssteel butt hinges and necessary S.S screws shall be paid separately) |
| 31 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (Code No. 22.60) |
| 32 | Providing and fixing factory made single extruded WPC (WoodPolymerComposite) solid door/window/Clerestory windows & other Frames/Chowkhat size 65 x 150 mm comprising of virgin PVC polymer of Kvalue 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ ricehusk/wheathusk)and nontoxic additives (maximum toxicityindex of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded starheaded SS screws having minimum frame density of 750kg/cum, screw with drawal strength of 2200N (Face)&1100N (Edge), minimum compressive strength of 58N/mm2,modulus of elasticity 900 N/mm2and resistance tospreadof flame of ClassA category with property of being termite/borer proof,water/moisture proof and fireretardant and fixed in position with M.Shold fast/lugs/SSdash fastenersof requireddiaand length complete as per direction of Engineer-In-Charge. (M.Shold fast/lugs or SS dash fastenersshall be paid for separately). |
| 33 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (Code No. 15.56) |
| 34 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) (Code No.15.2.1) |
| 35 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). (Code No. 4.1.10) |
| 36 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)( code No. 4.1.3) |
| 37 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. (Code No. 11.40) |
| 38 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Code No. 8.31) |
| 39 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Code No. 17.31) |
| 40 | Providing and fixing toilet paper holder : C.P. brass (Code No. 17.34.1) |
| 41 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.(Code No. 17.81) |
| 42 | Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 110 mm Dia (Code No. 110/27.29C) |
| 43 | Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 90 mm Dia (Code No. 110/27.29b) |
| 44 | Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 75 mm Dia (Code No. 110/27.29a) |
| 45 | Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. 111(Code No. 111/27.30a) 75mm dia |
| 46 | Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. 111(Code No. 111/27.30b) 90mm dia |
| 47 | Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. 111(Code No. 111/27.30c)100mm dia |
| 48 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.(code no. 11.55.1) |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(code No. 18.8.1) 15 mm dia. |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(code No. 18.8.2) 20 mm dia. |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(code No. 18.8.3) 25 mm dia. |
| 52 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge |
| 53 | S/F of Jaquar make pillar cock of model of FLR-5011N as per direction of engineer in charge. This include cost of labour, material T&P etc for proper completion of work. (CSI No. 26.27) |
| 54 | Supply and fixing of health faucet for model no-ALD-573 as per direction of engineer in charge. This include cost of labour, material T&P etc for proper completion of work. (CSI No. 26.30) |
| 55 | Supply and fixing of Under Counter table top wash basin Jaguar make model no-CNS-WHT-903 as per direction of engineer in charge This include cost of labour, material T&P etc for proper completion of work. (CSI No. 26.32) |
| 56 | Supply and fixing toilet paper holder for model no-AHS-1551 KN as per direction of engineer in charge. This include cost of labour, material T&P etc for proper completion of work. (CSI No. 26.33) |
| 57 | S/F of Jaquar make long body Bib Cock of model no CON-107PM as per direction of engineer in charge. This include cost of labour, material T&P etc for proper completion of work. (CSI No. 26.34) |
| 58 | S/F of Jaquar make Towel Rail of model No. AQN 7711A 450 mm long as per direction of engineer in charge. This include cost of labour, material T&P etc for proper completion of work. (CSI No. 26.36) |
| 59 | Supply and fixing of Angular stop cock of \\"Jaguar\\" make or equivalent Model No-FUS-29053as approved by E/I. This include cost of labour, material T&P etc. for proper completion of work. . (CSI No. 26.37) |
| 60 | 12 MM Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.. (Code No. 13.9.1) |
| 61 | 12 mm cement plaster of mix 1:4 (1cement:4coarse sand) |
| 62 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 63 | Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. or R.B. work (Payment shall bemade on the cross sectional area of R.C.C.or R.B.work)as per direction of Engineer-in |
| 64 | In-filling/sealing of joint between RCC lintel cum sunshade and wall (one xternal side) in all floors by pushing in Grout RW/ equivalent in paste form and coving 20mmx20 mm after applying a coat of Zycosil/ equivalent & zycoprime/equivalent solution before cement plastering of top, bottom and sides of RCC su |
| 65 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar (1 cement : 6 coarse sand) 1:6 |
| 66 | 12 mm cement plaster of mix 1:6 (1cement:6coarse sand) lumsum |
| 67 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 68 | Fixing window chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks of size15x10x10 cm with cement concrete1:3:6(1cement :3coarse sand:6graded stone aggregate 20mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, includingdisposalof rubbishtothedumpingground,allcompleteas per direction of Engineer-in-Charge |
| 69 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 70 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 71 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer,over the plastered wall surface to prepare the surface even and smooth complete. |
| 72 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 73 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 74 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 75 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 76 | Supply and fixing 6mm thick polycarbonate multiwall sheet ,fixing in position with J or U bolts 10 mm. dia with G.I. Limpet & bitumen washers including supply of all materials, labour,wastage. and T&P etc. required for proper completion of the work. (CSI No. 10.13) |
| 77 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 78 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail