| 1 | Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed |
| 2 | Taking down chowkats or frames, exc 1.5 sqm but not exc 4 Sqm each with shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also Grills/Guard bars (where exists), complete all as specified and directed. |
| 3 | Taking down chowkats or frames, not exc 1.5 sqm each with shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also Grills/Guard bars (where exists), complete all as specified and directed. |
| 4 | Taking down and refixing in the same opening shutters of any description exceeding 1 Sq.m but not exceeding 2 Sq.m each complete all as specified and directed. |
| 5 | Taking down shutters of any description exceeding 1 Sq.m but not exceeding 2 Sq. M each complete all as specified and directed. |
| 6 | Demolition of cement concrete in ground floors (un-reinforced) and paving not exc. 15cm thickness (below or above ground level) including removing debris outside MD land complete all as specified and directed. |
| 7 | Demolition of cement concrete (reinforced) as in roofs, shelves, chajjas, floors (other than ground floors), beams, staircase, landing, chajjas , parapet, water tank and similar suspended work etc. and removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 8 | Demolition of brickwork built in cement mortar including disposal of debris, etc outside MD land, complete all as specified and directed. |
| 9 | M&L for brick work with sub class B old size bricks straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 10 | M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 11 | M & L for dubbing out with CM 1:4 average 15mm thick on irregular face of walls complete all as specified and directed. |
| 12 | M & L for cement plaster 20 mm thick in CM 1:4, two coats using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd/, Fosroc or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnIcal mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 15 mm thick and finishing coat of 5 mm thick final rendering,including using richer mix for making corners if necessary, including water proffing powder at 3 % of cement at all floors and level, including making grooves of existing size wherever required, including providing Galvanized hexagonal chicken wiremesh 19 to 22 guage at RCC & brick in joints , including cleaning the surfaces, curing etc. complete all as per specifications & as directed by the EIC note: water proofing powder will be measured and paid seperately. |
| 13 | M&L for rendering 10 mm thick using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Soundp last PMC-1 of M/s Sound buildcare Pvt Ltd/ , Fosroc or other approved equivalent make, having minimum composition of C:S : 1:6 using fully treated dry, well graded natural sand confirming to IS 383 suitable for internal wall plastering, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over masonry and concrete surfaces, etc. complete all as specified & directed by Engineer-in-Charge. |
| 14 | M&L for rendering 5 mm thick on ceiling using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Soundp last PMC-1 of M/s Sound build care Pvt Ltd/ ., Fosroc or other approved equivalent make, having minimum composition of C:S : 1:3 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering in ceiling, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over concrete surfaces, etc. complete all as specified & directed by Engineer-in-Charge . |
| 15 | M&L for preparation of new plastered surfaces of internal walls and applying two coat of oil bound distemper including application of 3mm thick wall care putty and one coat of primer for smooth finishs all as specified and directed. |
| 16 | M&L for preparation of new plastered surfaces of ceiling and applying two coat of oil bound distemper including application of 3mm thick wall care putty and one coat of primer for smooth finishs all as specified and directed. |
| 17 | M&L for complete removal of Old internal wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying with roller two coat of oil emulsion distemper including application of wall care putty as per requirement for smooth finish all as specified and directed. |
| 18 | M&L for complete removal of Old surface of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying two coat of oil emulsion distemper all as specified and directed. |
| 19 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Note:- The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE. |
| 20 | Material & Labour for old undecorated surfaces of external walls,soffits & fascias of chajjas etc and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Note:- The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE. |
| 21 | Note :- (a) Rate quoted against BOQ sr item No 15 to 20 shall deemed to include scaffolding, trestles, ladders, cradles and protective measures etc, wherever required for execution of work of height upto 04 storey building, Contractor shall quote their tender keeping this aspect in mind.b) The work pertaining to periodical services shall be executed as per MoU between tenderer and manufacturer of paints and their authorised applicator after approval by the GE as per MoU Performa attached at Serial page No. 107 & 108. (c) The Contractor shall upload with the documents under cover I \\"Memorandum of Understanding\\" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall not be opened and shall be liable to rejected. |
| 22 | d) Scaffolding, trestles, ladders, cradles and protective measures etc, as necessary for execution of work shall be arranged by the contractor without any extra cost to the department. (e) Authorised applicator of the company with trained painters will only be allowed to execute the work and the applicator will submit the experience certificate from the company.f) The entire quantity of material will be calculated and brought in a maximum 3 phases and will be accepted only post verification of PVs and Challan from the company through Mail.(g) The entire of material will be kept in the custody of MES rep and will be issued to the authorised applicator as per requirement. (h) Packing material/ empty Buckets will not be handed over to the contractor and will be destroyed after completion of work through a BOO. Buildings will be handed over to the contractor in a phased manner and subsequently to the authorised applicator only after completion of civil work like plastering/ repairing as required. |
| 23 | j) Entire work will be divided into four stages as under and will be certified by a company technical rep whether the stages completed are as per manufacturer's instruction and passed by Engineer-in-Charge/GE:- (i) Stage: 1 Preliminary Inspection (ii) Stage 2: Preparation of surface (iii) Stage 3: Priming/ Base Coat (iv) Stage 4: Final coat of painting.(k) Stage passing register will be properly maintained duly signed by all Concerned.(l) Preparation of plastered or un plastered surface or removal of existing treatment by scrapping of walls, chajjas, ceilings, fins, facials etc. shall be done using mechanical sander with internal dust extraction system for clean environment. (m) All priming/ painting work will be done by mechanical sprayer only. |
| 24 | (n) All rates quoted will be inclusive of all scaffolding as and when required as per the schedule attached and no work will be allowed without proper scaffolding, height of each building are as indicated in the list of buildings. (o) The contractor shall submit manufacturer generated 05 years warranty card for each building during submission of RAR and Final Bill. (p) A warranty amount @ 10% will be kept as reserve till completion of warranty period and will be released thereafter.(q) Any deterioration during the warranty period will be rectified by the contractor from the manufacturer with whom the MoU is signed, without any financial effect. |
| 25 | M&L for fixing factory made 100% solid WPC ( Wood Polymer Composite)- Door Frame 125 mm x 65 mm double rebated, made from wood polymer composite (single Extruded Process) material comparising of virgin PVC polymer of K Value 57-60 (Suspension Grade), calcium carbonate and natural Fibers (Wood Powdwe/ Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter joint after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/cbm, having good screw holding capacity (Screw Withdrawal strenght of (min. 990 N0, minimum compressive strength of 58 N/mm2, modulus of elasticity 900N/mm2 and resistance to spread of frame of class A category with property of being termite / borer proof, water / moisture proof & fore retardent & Fixed in position with SS Dash Fasteners / Hold fast of reuired dia and lenght , all as per specification drawing as directed by the Engineer-in-Charge. material test certificate and authentication should be compulsory provided by the manufacturing company complete all as specified and directed. |
| 26 | M&L for fixing factory made 100% solid WPC (Wood Polymer Composite)- Door Frame 100 mm x 50 mm single rebated, made from wood polymer composite (single Extruded Process) material comparising of virgin PVC polymer of K Value 57-60 (Suspension Grade), calcium carbonate and natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter joint after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/cbm, having good screw holding capacity (Screw Withdrawal strenght of (min. 990 N0, minimum compressive strength of 58 N/mm2, modulus of elasticity 900N/mm2 and resistance to spread of frame of class A category with property of being termite / borer proof , water / moisture proof & fore retardent & Fixed in position with SS Dash Fasteners / Hold fast of reuired dia and lenght , all as per specification drawing as directed by the Engineer-in-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company complete all as specified and directed. |
| 27 | S&F Providing factory made 28-30mm thick 100% solid WPC (Wood Polymer Composite)- Laminated Flush Door Shutter of required size comparising of virgin PVC resin of K Value 57-60 (Suspension Grade), calcium carbonate and natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) and Non toxic additives, made from Extrusion process WPC foam sheet single Extruded ( inner) with having minimum density not less than 650 kg/cbm, having good screw holding capacity ( screw withdrawal strenght of 50 N (Face) & 1100 N (Edge), minimum compressive strength of 50 N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of frame of class A category with property of being termite / borer proof , water / moisture proof & fore retardent. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of vshutter and fixing stainless steel butt hinges (will be paid seperately ) of required size with necessary full body threaded star headed counter sunk SS screw. all as per specification drawing as directed by the Engineer-in-Charge. material test certificate and authentication should be compulsory provided by the manufacturing company complete all as specified and directed. |
| 28 | S&F Providing factory made 28-30mm thick 100% solid WPC ( Wood Polymer Composite)- JALI Door Shutter of required size comparising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), calcium carbonate and natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives, made from Extrusion process WPC foam sheet single Extruded ( inner) with having minimum density not less than 650 kg/cbm, having good screw holding capacity ( screw withdrawal strenght of 2000 N (Face) & 1100 N (Edge), minimum compressive strength of 50 N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of frame of class A category with property of being termite / borer proof , water / moisture proof & fore retardent. WPC JALI Door to be fixed with stainless steel wire cloth .36 mm nominal dia of wire and average width of aperature 1.10mm and fixed with stainless steel wire staples stainless steel butt hinges ( will be paid seperately) of required size with necessary full body threaded star headed counter sunk SS screws.all as per direction of Engineer-in-Charge. material test certificate and authentication should be compulsory provided by the manufacturing company complete : For Kitchen shutterd / Balcony & main door shutter,completed all as specified and directed. |
| 29 | S & F factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and shown in drg for SI No. 8095 on ser page No. 160 in SSR-2010 (Pt-II), complete all as specified and directed. |
| 30 | S&F factory Made solid Panel PVC Door Shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet with Free EPS shall be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, as per specification & drawing for SI No.8080 on ser page No.156 in SSR-2020 (Pt-II), complete all as specified and directed. |
| 31 | M&L for factory made 18mm thick WPC sheet of minimum density 600kg/cbm manufactured by an ISO-900-2008 certified company, One side prelaminated and other side plain 18mm thick WPC sheet Ply for cupboard shutter and also manufacturer's test report and test certificate is mandatory with each and every supply of the material, complete all as specified and directed. |
| 32 | M&L for factory made 18mm thick WPC sheet ply of minimum density 600kg/cbm manufactured by an ISO-900-2008 certified company, Both sides plain 18mm thick WPC sheet Ply for cupboard shelf/partition/drawer and also manufacturer's test report and test certificate is mandatory with each and every supply of the material, complete all as specified and directed. |
| 33 | S&F bands, straps, supports or stays for rainwater, hold fasts etc and similar small articles made out of mild steel Flat etc of grade Fe-290 Gde - E-165 etc complete all as specified and directed. |
| 34 | M & L for PCC 1:2:4 type B1 cement concrete as in bed blocks etc for hold fasts etc including provision of necessary form work, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 35 | M & L for PCC 1:2:4 type B1 cement concrete as in bed blocks etc for hold fasts etc including provision of necessary form work, complete all as specified and directed. Please Enable Macros to View BoQ information |