| 1 | Dismentalling of existing of plaster and raking out joints of brick work in cement mortar to a depth of 1 cm. including disposal of refuse as directed by E/I within a distance 60 meters (200 feet). SI No 706+707 |
| 2 | Excavation in foundation in ordinary soil (loamclay or sand) including lift up to 1.5m and lead up to 30m. and including filling watering and ramming of excavated earth into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth ad directed by the Engineer in charge up to a distance of 30m. from the foundation trenches including all T&P phowarah and basket etc. complete.. (SI No. 251) |
| 3 | Concrete with 4cm. gauge approved stone ballast, approved coarse sand and cement in the proportion of 6:3:1 including supply of all materials labour and tools and plants etc. required for proper completion for the work. (SI.No.280) |
| 4 | M-150 brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all material, labour and tools and plants. ect. required for proper completion of work. (SI.No.333a) |
| 5 | M-150 brick work in 1:4 cement and coarse sand mortar in foundation and plinth including supply of all material, labour and tools and plants. ect. required for proper completion of work. (SI.No.307) |
| 6 | R.C.C. work with cement approved coarse sand and 2cm Gauge approved stone ballast in the proportion of 1:2:4 in lintels of doors and windows, excluding its fixing and binding the same with 24B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including S/o all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost.. (SI.No.288) |
| 7 | Mild steel or iron work of small size and sections such as holding down bolts, hold fast tie roads, gatings etc. (When not included in an overall rates) wrought to required form including supply of steel and its wastage including cost of bolts, nuts if required and welding, grinding and making holes as required for proper completion of work fabrication of holes, Doors chaukhats and nosing. (SI.No.502) |
| 8 | 12mm thick plaster with cement mortar consisting of 1 part cement and 3 part of approved coarse sand. Minimum thickness not be less than 10mm including supply of all materials, labour and T&P etc. required for proper completion of the work.. (SI No. 584) |
| 9 | Scraping of old white or colour wash including disposal of refuse as directed by E/I within a distance of 60 meters (200 feet) SI No. 708 |
| 10 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicon additives of required shade New work (Two or more coats applied @ 1.43 Ltr/10sqm over and including base).CPWD 13.47.1 |
| 11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR13.80) |
| 12 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. (DSR 13.43.1) |
| 13 | Wall painting with two coat on interior wall surface with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, to achieve even shade and colour. (DSR 13.83.2) |
| 14 | Painting or varnishing of two coat on old wood work including its sand preparing, rubbing and cleaning as required and supply of all materials, labours,T&Ps etc for proper completion of the work. (SI 642+643) |
| 15 | Dismantling cement concrete or brick or granolithic floors and including stacking of dismantled materials as directed by Engineer - in - charge within a distance of 60 meters (200 feet). (SI No. 697) |
| 16 | Providing and Laying vitrified floor tiles of approve make and Brand in difference size (thickness specified by manufacturer) with water absorption less than 0.8% and confirming to IS 15622 of approved make in all colors and shade laid on 20mm thick cement mortar 1:4 (Icement 4 coarse sand) including grouting the joints with white cement and matching pigments etc complete size of tiles 600x600mm. As per SoR CPWD 11:41:1 |
| 17 | Providing and fixing White Vitreous China Wash basin size 550x400 mm with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required. (DSR 17.7A) |
| 18 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required . (DSR 17.3.1) |
| 19 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (DSR 17.16A) |
| 20 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes including jointing with seal ring, leaving 10 mm gap for thermal expansion. (DSR 12.41.2) |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge .Concealed work, including cutting chases and making good the walls etc. (20 mm dia) (DSR 18.8.2) |
| 22 | Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer’s specification, with all 4 side tapered and backed by ac |
| 23 | Providing and fixing of PVC SHEET WALL PANELLING as per direction of Engineer incharge. Please Enable Macros to View BoQ information |