| 1 | Excavation in any type soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth (for cable, pole, stay etc) and getting out complete all as specified and directed. |
| 2 | Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed. |
| 3 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 4 | M&L for providing dry river sand as in sand cushioning to UG cable including punning gently complete all as specified and directed. Note : Depth after punning shall be measured and paid. |
| 5 | Supply and laying reinforced precast concrete cable cover, class LHV, type 2 flat of size 300mm x 180mm x 40mm for cable protection under trenches complete all as specified and directed. |
| 6 | S&F, in repair, GI pipe, 80 mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping, etc complete all as specified and directed. |
| 7 | S&F, in repair, GI pipe, 50 mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping, etc complete all as specified and directed. |
| 8 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and directed. |
| 9 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed. |
| 10 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed. |
| 11 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed. |
| 12 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed. |
| 13 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed. |
| 14 | Supply and fixing of LT switch gear Panel Made out of CRCA sheet 3.15mm thick sheet steel ,outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection Class IP 54), (front opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall duly powder coated with colour shade RAL 7035 Siemens grey Pure Polyester adopting 8 tank pre-treatment of fabricated job before powder coating, the panel shall consisting of TPN main aluminium bus bar of 600 Amp rating covered with heat sleeves with colour coding and the complete panel shall be mounted on frame work made out from 50x50x6 mm angle iron duly painted with black pain comprising with the followings complete all as specified and directed:- (a) MCCB TPN 400 Amps, 36 KA breaking capacity with adjustable thermal and fixed magnetic (Ics = % Icu) 100% - 01 No (Main Incomer)(b) MCCB TPN 63-100 Amps, 27 KA breaking capacity with adjustable thermal and fixed magnetic with Ics = % Icu at 415V - 06 No (o/g)(c) MCB TPN 63 Amps 10 KA breaking capacity, 415 Volt - 02 Nos (d) One spare space for fixing of MCCB(e) Volt meter 0-500 Volt (Digital type)(f) Ampere meter 0-600 Amps (Digital type)(g) Suitable rating ampere of CT/PT for metering system. |
| 15 | Supply and fixing of LT switch gear Panel Made out of CRCA sheet 3.15mm thick sheet steel ,outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection Class IP 54), (front opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall duly powder coated with colour shade RAL 7035 Siemens grey Pure Polyester adopting 8 tank pre-treatment of fabricated job before powder coating, the panel shall consisting of TPN main aluminium bus bar of 500 Amp rating covered with heat sleeves with colour coding and the complete panel shall be mounted on frame work made out from 50x50x6 mm angle iron duly painted with black pain comprising with the followings complete all as specified and directed:- (a) MCCB TPN 250 Amps, 36 KA breaking capacity with adjustable thermal and fixed magnetic (Ics = % Icu) 100% - 01 No (Main Incomer)(b) On load change over switch 250 Amps, 4 Pole 36 KA (b) MCCB TPN 40 Amps, 16 KA breaking capacity with adjustable thermal and fixed magnetic with Ics = % Icu at 415V - 07 No (o/g)(c) MCB SPN 63 Amps 10 KA breaking capacity, 230 Volt - 06 Nos (d) One spare space for fixing of MCCB(e) Volt meter 0-500 Volt (Digital type)(f) Ampere meter 0-500 Amps (Digital type)(g) Suitable rating ampere of CT/PT for metering system. |
| 16 | Supply and fixing of LT switch gear Panel Made out of CRCA sheet 3.15mm thick sheet steel ,outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection Class IP 54), (front opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall duly powder coated with colour shade RAL 7035 Siemens grey Pure Polyester adopting 8 tank pre-treatment of fabricated job before powder coating, the panel shall consisting of TPN main aluminium bus bar of 400 Amp rating covered with heat sleeves with colour coding and the complete panel shall be mounted on frame work made out from 50x50x6 mm angle iron duly painted with black pain comprising with the followings complete all as specified and directed:- (a) MCCB TPN 160 Amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic with Ics 100% - 01 No (Main Incomer)(b) On load change over switch 160 Amps, 4 Pole 415 Volt (c) MCCB TPN 40 Amps, 16 KA breaking capacity with adjustable thermal and fixed magnetic with Ics = % Icu at 415V - 04 No (o/g)(d) MCB SPN 63 Amps 10 KA breaking capacity, 230 Volt - 03 Nos (e) One spare space for fixing of MCCB(f) Volt meter 0-500 Volt (Digital type)(g) Ampere meter 0-500 Amps (Digital type)(h) Suitable rating ampere of CT/PT for metering system. Please Enable Macros to View BoQ information |
| 17 | Supply and fixing of LT switch gear Panel Made out of CRCA sheet 3.15mm thick sheet steel ,outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection Class IP 54), (front opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall duly powder coated with colour shade RAL 7035 Siemens grey Pure Polyester adopting 8 tank pre-treatment of fabricated job before powder coating, the panel shall consisting of TPN main aluminium bus bar of 400 Amp rating covered with heat sleeves with colour coding and the complete panel shall be mounted on frame work made out from 50x50x6 mm angle iron duly painted with black pain comprising with the followings complete all as specified and directed:- (a) MCCB TPN 160 Amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic with Ics 100% - 01 No (Main Incomer)(b) On load change over switch 160 Amps, 4 Pole 415 Volt (c) MCCB TPN 40 Amps, 16 KA breaking capacity with adjustable thermal and fixed magnetic with Ics = % Icu at 415V - 04 No (o/g)(d) MCB SPN 63 Amps 10 KA breaking capacity, 230 Volt - 03 Nos (e) One spare space for fixing of MCCB(f) Volt meter 0-500 Volt (Digital type)(g) Ampere meter 0-500 Amps (Digital type)(h) Suitable rating ampere of CT/PT for metering system. Please Enable Macros to View BoQ information |