| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. |
| 2 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and directed. |
| 3 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 4 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 flat of size 300mm x 180mm x 40mm complete all as specified and directed.. |
| 5 | Material and labour for Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed. |
| 6 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. |
| 7 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. |
| 8 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 240 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. |
| 9 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 150 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. |
| 10 | Material and labour for fault finding of HT 11 KV 3 core, XLPE cable of size 95/120/185 sqmm by thumping and echo instrument/ computer aided fault finding kit, and finding out exact location of the fault complete all as specified and directed .Note :(i) Necessary excavavation, reterning refilling and removal of soil shall be measured and paid separately under relevant items of the schedule. |
| 11 | Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV XLPE earthed UG cable of size 3 core 50 to 95 Sqmm aluminum conductor and testing complete all as directed |
| 12 | Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV earthed XLPE earthed UG cable of size 3 core 120 to 185 Sqmm aluminum conductor and testing complete all as directed |
| 13 | Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV earthed XLPE earthed UG cable of size 3 core 240 to 400 Sqmm aluminum conductor and testing complete all as directed |
| 14 | Supply and fix in repair Indoor type cable terminations (heat shrinkable) with all accessories suitable for 3 core 11KV HT U/G XLPE earthed cable of size 50 to 95 sqmm Sq.mm including testing complete all as specified and as directed . |
| 15 | Supply and fix in repair Indoor type cable end terminations (heat shrinkable) with all accessories suitable for 3 core 11KV U/G XLPE earthed cable of size 120 to 185 sqmm Sq.mm including testing complete all as specified and as directed . |
| 16 | Supply and fix in repair outdoor type cable terminations (heat shrinkable) with all accessories suitable for 3 core 11KV U/G XLPE earthed cable of size 50 to 95 Sq.mm including testing complete all as specified and as directed. |
| 17 | Supply and fix in repair outdoor type cable end terminations (heat shrinkable) suitable for 3 core 11KV U/G XLPE earthed cable of size 120 to 185 Sq.mm including testing complete all as specified and as directed . |
| 18 | Material and labour for Preparing to old painted steel/metal surface of any description over 10 CM in width or girth of HT VCB panel indoor/Outdoor of various locations and applying two coats of synthetic enamel paint with fine quality with suitable spray gun including writing of panel details all as specified and as direted. Note:-(i) Writing includes SL No, details of Incoming and outgoing, area indication as directed by Engineer- in-Charge |
| 19 | Online Centrifuging (filteration/dehydration) of transformer oil including checking initial and after filteration Dielectric Strength of oil for transformers, Isolation transformers and voltage stabilizers located in various places of technical and domestic area with suitable machine having filteration, heating and pumping facility to improve the dielectric strength/insulation value of oil.Note :- (i) Di electric strength of oil after filteration/dehydration shall not be less than 60 KV at 2.5 mm gap.(ii) Oil for toping up shall be measured and paid separately under relevant item of this schedule(iii) The contractor will take shut down orders in writing atleast two days before from Engr-in-charge before commencement of work.(iv) The dielectric strength of oil shall be tested before and after filtration and necessary test certificates shall be submitted to the Engr-in-charge. |
| 20 | Online Centrifuging (filteration/dehydration) of transformer oil including checking initial and after filteration Dielectric Strength of oil for transformers, Isolation transformers and voltage stabilizers located in various places of technical and domestic area with suitable machine having filteration, heating and pumping facility to improve the dielectric strength/insulation value of oil.Note :- (i) Di electric strength of oil after filteration/dehydration shall not be less than 60 KV at 2.5 mm gap.(ii) Oil for toping up shall be measured and paid separately under relevant item of this schedule(iii) The contractor will take shut down orders in writing atleast two days before from Engr-in-charge before commencement of work.(iv) The dielectric strength of oil shall be tested before and after filtration and necessary test certificates shall be submitted to the Engr-in-charge. |