| 1 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for Roof kerb,roof padding concrete etc all as specified and directed. |
| 2 | Taking down existing water proofing treatment on the roof, cleaning with wire brush etc., and removing debris outside MD land complete all as specified and as directed. |
| 3 | Demolition for brickwork or stone/PCC block masonry laid with cement mortar mortar complete all as specified and directed. |
| 4 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 6 | Taking down steel tubing and connections of 20 mm bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 7 | Taking down steel tubing and connections of 25 mm bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 8 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings all as directed |
| 9 | Taking down PVC SWR pipe of any pattern and any size including fittings like bend(Y/T),cowl, etc all as specified and directed. |
| 10 | M & L for PCC (1:2:4 type B-0 (using 12.5mm graded stone aggregate) lintels upto 1.5m clear span, cills, steps; seismic and other similar bands plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throati as in roof padding, coping,kerbs, bed plates, hold fast blocks, etc., including formwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 11 | M&L for screed bed or bedding layer of mortar 20mm thick in Cement Mortar 1:4 mixed with liquid water proofing compound as per manufacturer's instructions on on fair faces of concrete surfaces over roof slab complete all as specified and as directed.Note: Liquid water proofing compound shall be measured and paid separately.Make : Fosroc/Dr Fixit/Asian Paint |
| 12 | M&L for laying 3mm thick APP modified water proofing membrane weighing not less than 3.6 Kg/Sqm, reinforced with non woven polyster matt black finished weighing not less than 100 gm/Sqm having softening point not less than 140 degree celsius longitudinal tensile strength not less than 300 N/Sqm, side lap & end lap 15cm over a coat of bitumen primer @ 0.20 Kg/Sqm and finished with aluminum paint @ 0.10 Ltr/Sqm all as per manufactures instruction and all as specified and directed.Note : The work shall be carried out by authorised applicators of manufactures. |
| 13 | M&L for cleaning the surface to remove all dust, dirt etc including Priming the surface with one coat of Smartcare Bituminous primer of make -Asian Paints/ equivalent to enhance the bonding properties. Providing and laying of protective Geotextile fabric 45GSM with proper overlaps. Supplying and applying two coat of single component, elastomeric,pitch modified PU coating Smartcare Flexiseal PU or approved equivalent with minimum elongation of 300% and tensile strength of 2 N/mm2 as per ASTM D412 and Shore A Hardness of 90 as per ASTM D 2240. The PU Coating shall have crack bridging ability of 2mm. The system consists of applying the water proofing treatment @ 1.2 Kg/ Sqm and shall have crack bridging ability of 2mm etc complete as per manufacturer's instruction and all as specified and directed.Note: The treatment should be carried out by the authorised applicator of the company |
| 14 | M&L for heavy duty vitrified unpolished porcelain floor tiles of size 300 x 300mm, 10mm thick of make Neo Deccan Natural of somany or Endura of Johnson or equivalent of other specified makes suitable for heavy vehicle movement, laid in floors /skerting of parepet etc of pattern as approved, pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specifiedset and jointed with Ezy Grout with spacers of somany to match complete all as specified and directed. |
| 15 | M&L for Precast cement concrete block Type C1(1:3:6)(using 20 mm graded aggregate) masonry with solid solid blocks exc 10cm width and setting in mortar(1:6) complete all as specified and directed. |
| 16 | M&L for providing precast cement concrete solid building blocks or slabs 10cm thick in type C-1(1:3:6) using 20mm graded stone aggregate (with plain or interlocking joints as directed) setting in cement mortar(1:4) complete, in walls,partion,platform support etc complete all as specified and directed |
| 17 | Material and labour for Rendering in Cement Mortar (1:6) 15mm thick on block masonry surface or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.. |
| 18 | Material and labour for rendering 15mm thick in Cement Mortar 1:3 mixed with liquid water proofing compound as per manufacturers' instructions on PCC block masonry surface or concrete surface of any description finished even and smooth without using extra cement complete all as specified and as directed. Note: Liquid water proofing compound shall be measured and paid separately. |
| 19 | Excavation in post holes (or similar holes) each not exc 0.5 Cum and getting out, returning filling in and ramming earth or borken rubble mixed with earth around in layers not exc 25cm watering and removing surplus spoil to a distance not exc 50m and making good surface in soft/loose soil all as specified and directed. |
| 20 | M&L for providing cement concrete 1:3:6, type C2, using 40mm aggregate, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts bases etc complete all as specified and directed. |
| 21 | M & L for mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat, square tube etc sections) including distance pieces, cleats etc. Fe 410-W (Gde-E- 250) quality- A complete all as specified and as directed. |
| 22 | M&L for MS Framed work such as grills, gratings,FI support for barge board,Fascia,water tank staging ladders; framed balusters; walk ways; railings; and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 23 | S&F Welded steel wire fabric supplied and fixed complete to wood or steel members n exc 4 kg complete all as specified and as directed. |
| 24 | S&F prepainted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strenth of 550MPA as in roof covering /cladding to wall,crimp curved where necessary fixed with self tapping screws complete all as specified and directed. |
| 25 | S & F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 26 | M/L preparing new surface of steel and appling two coats of synthetic enamel paint over a coat of primer red oxide complete. |
| 27 | M&L Complete removal of existing treatment on wall by scrapping, washing, rubbing down and stopping of distempered and applying two coats of oil bound distemper over a coat of primer on walls all as specified and directed . |
| 28 | Complete removal of existing treatment on external walls (Plastered or RRM surface) by wire brushing, crack filling & Bio-wash to fight microbial growth one coat of exterior wall primer and two coats of Exterior Emulsion anti fungal weather proof paint APEX ULTIMA OF Asian Paint or WEATHER COAT SMOOTH of Berger complete all as per manufacturer instruction and all as specified and directed . |
| 29 | M&L Preparing newly plastered surfaces of external walls and applying one coat of exterior wall primer and two coats of Exterior Emulsion anti fungal weather proof paint APEX ULTIMA OF Asian Paint or WEATHER COAT SMOOTH of Berger complete all as per manufacturer instruction and all as specified and directed . |
| 30 | M&L for preparation of new surfaces of walls a applying two coats of Oil bound distermper over a coat of primer complete all as specified and directed . |
| 31 | Material and labour for one coat of putty average thickness 1.5mm thick) on wall surface of any description complete all as specified and directed . |
| 32 | S&F 20 mm bore Galvanised iron tubing, medium grade, with all fittings laid to walls, ceiling, floors, etc complete all as specified and as directed. |
| 33 | S&F 25 mm bore Galvanised iron tubing, medium grade, with all fittings laid to walls, ceiling, floors, etc complete all as specified and as directed. |
| 34 | Refixing of old GI steel tubes and connections after cleaning of 20 mm bore in new or old position, any grade, to walls, ceiling, floors, etc complete all as specified and as directed. |
| 35 | Refixing of old GI steel tubes and connections after cleaning of 25 mm bore in new or old position, any grade, to walls, ceiling, floors, etc complete all as specified and as directed. |
| 36 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position of capacity exc 250 Ltr but n.exc 500 litres complete all as specified and as directed. |
| 37 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position of capacity exc 500 litres & n.exc 1000 litres complete all as specified and directed. |
| 38 | Supply and Fix 1000 litres capacity triple layered Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks, (Cylindrical vertical with closed top) screwed lid type conforming to IS 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed including dismantling old un serviceable tank |
| 39 | Supply only liquid water proofing compoundof approve make all as specified and directed . |
| 40 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 41 | S & F PVC (SWR) bends any radious 75mm bore provided with acess doorall as specified and directed . Please Enable Macros to View BoQ information |