| Sl. No. | Item Description |
| 1 | B/R PORTION: Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for and M & L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregates for filleting, benching, slightly rounding or chamfering on edges, filling undulations / depressions in roof surface, providing concrete platform for tanks wherever required complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Taking down / removing existing water proofing treatment from RCC roof slab including removal of plaster bed below felt / membrane and disposal of the same to distance exceeding 50m but not exceeding 100m as and where directed and M & L for 10 mm thick screeding / rendering in cement mortar 1:3 on concrete roof surface, using Water Proofing Compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note: Water Proofing Compound shall be measured and paid separately. |
| 3 | Supply only intergral water proofing compound complete all as specified and as directed by Engineer-in-Charge. |
| 4 | M&L for Cutting out cracks to \\"V\\" section in existing roofs or terracing, cleaning out wetting grouting with cement and sand slurry 1:3 complete all as specified and as directed by Engineer-in-Charge. |
| 5 | M & L for cleaning the plastered /concrete surface with wire brush and applying water proofing treatment as under:-(a) Apply a uniform coat of primer at 0.70 kg/sqm over cement plaster. (b) 3 mm thick and weighing not less than 3.6 kg/sqm Atactic Polypropylene Polymer (APP) modified bitumen - based prefabricated five layer water proofing membrane reinforced with non woven polyester matt black finished over compatible primer at 0.40 Ltr/sqm of density at 25 degree centigrade 0.87 - 0.89 kg/litre and viscosity 70-160 cps or cold sticker and torch application of membrane with 10 cm overlap both ways after necessary preparation of surface complete as per manufacturers instructions. (c) Apply two coats of bitumastic - aluminium paint over the membrane. |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level ) complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M & L for 25 mm thick PCC 1 :2 : 4 type B0 ( Using 12.5 graded stone aggregate ) as in base of floors complete all as specified and as directed by Engineer-in-Charge. |
| 8 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick in CM (1:6) Screed bed or bedding layer of mortar for laying floor finishes complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L Coloured Glazed ceramic tiles 450x300X7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M&L Coloured Vitrified tiles 10mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile laid over and including 15 mm thick screed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 11 | All as per item No 10 above but as in skirting over 10 mm thick rendering in cm 1:4 |
| 12 | Demolition of brick work or stone masonry or block masonry built in cement or cement/lime mortar. |
| 13 | M&L for PCC solid block masonry of blocks of type C1 (20mm graded stone aggregate) (1:3:6) wall exceeding 10cm in width & built in CM (1:6) complete complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Demolition of Stone slabs and tiles of any description or thickness laided bedded and pointed in cement mortar in floors, aprons etc. |
| 15 | M & L for 20mm thick Granite slab machine cut in laid over cement screed and jointed with grey cement slurry and pointed with whiteor colour cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete including screed bed 15mm thick in CM 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 16 | M & L for 20mm thick Granite slab machine cut in dado/skirting over cement screed and jointed with grey cement slurry and pointed with whiteor colour cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete including rendering of 10mm thick in CM 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 17 | M&L for 20-25mm thk machine cut cuddappah stone as in slab flooring over cement screed bed laid and jointed with grey cment slurry mixed with pigment to match the shade of the slab incl grinding polishing laid over 15 mm thick screed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Taking down cement or cement lime plaster on brick or stone walls,ceilings etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-Charge. |
| 20 | M & L for 15 mm thick plastering in cement mortar 1:4 on external plaster finished the surfaces using 3% of WPC of weight of cement used or as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge. |
| 21 | M&L for preparation to new surface and applying finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L for complete removal of existing treatment, preparing the surfaces and applying finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed by Engineer-in-Charge. |
| 23 | ditto all as in item No. 22 above 5 mm thick in CM 1:4 finished even & smooth but as in ceiling complete all as specified and as directed by Engineer-in-Charge. |
| 24 | M & L for applying three coat of white wash on ceiling including preparation of new surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 25 | M & L for applying one coat of white wash on celing on old surfaces including preparation of old surfaces including cleaning smoke efflorocense of any type or spot of nail filled with putty complete match to old surface complete all as specified and as directed by Engineer-in-Charge. |
| 26 | M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing the surface with a thin layer of sagolcomplete all as specified and as directed by Engineer-in-Charge. |
| 27 | M & L preperation of new plastered surfaces & applying two coats of oil bound distember over a coat of alkali resistant primer complete all as specified and as directed by Engineer-in-Charge. |
| 28 | .M&L for complete removal of existing finishes and applying two coats of oil bound distemper on walls over a coat of alkali resistant primer including alkali resistance primer, preparation of old surfaces , on plastered surfaces prepratary to distempering complete all as specified and as directed by Engineer-in-Charge. |
| 29 | M& L for preparation of new surfaces of wall and applying three coats of white wash on walls complete all as specified and as directed by Engineer-in-Charge. |
| 30 | M& L for complete removal of existing finishes and applying three coats of white wash on walls including preparation of old surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50m but n. exc 4.00 sqm complete all as specified and as directed by Engineer-in-Charge. |
| 32 | S & F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, size of frame 105x60mm complete all as specified and as directed by Engineer-in-Charge. |
| 33 | M&L For PCC cement concrete type B0, 1:2:4 (12.5 mm graded aggregate) in door and windows frames, any size, single or double rebated, including arrangement for fixing of hinges and fixtures as required complete all as specified and as directed by Engineer-in-Charge. |
| 34 | M & L for flush shutters 30mm thick solid core constructions with block board core , ply wood face panels commercial type on both side complete all as specified and as directed by Engineer-in-Charge. |
| 35 | S & F Aluminium, anodised, barrel tower bolts of extruded section 200 mm long. |
| 36 | S & F Aluminium handles, cast type, anodised size 150 mm long. |
| 37 | S & F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed by Engineer-in-Charge. |
| 38 | S & F Mild steel Butt hinges100 mm long, medium weight, cold rolled steel complete all as specified and as directed by Engineer-in-Charge. |
| 39 | S&F Solid PVC door frame of size 50mm X47 mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube suppling and fixing in opening complete all as specified and as directed by Engineer-in-Charge. |
| 40 | S & F MS Butt hinges 75 mm long, medium weight, cold rolled steel. |
| 41 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip if 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bootom rail on either side & as gap insert for top rail and bottom rail ; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles. & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling and fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer-in-Charge. |
| 42 | S & F Aluminium, anodised, barrel tower bolts of extruded section 125mm long complete all as specified and as directed by Engineer-in-Charge. |
| 43 | S & F Aluminium handles, cast type, anodised size 125 mm long complete all as specified and as directed by Engineer-in-Charge. |
| 44 | Taking down chowkat without taking off shutter from frame n.exc 1.5 sqm each complete all as specified and as directed by Engineer-in-Charge. |
| 45 | S&F Powder coated aluminium powder coated window sliding type (3 track) with frame size100x35x1.2mm and shutter 39.40x17.70x1.2mm with two glass shutter & one mesh shutter incl necessary jointing cleats cleats, glazing clips, rubber packing, powder coated aluminium snap beading screws with 4mm plain float glass & 0.56 mm dia SS wire mesh, fittings etc of complete all as specified. |
| 46 | S&F coloured UPVC door having thickness 2.3 mm with frame size 67 x 64and shutter size 67 x 110 and glazing 5 mm thick tinted glass or ACP sheet 4mm in panels, uPVC extruded glazing beads of appropriate dimension,EPDM gasket, zinc alloy hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, necessary stainless steel screws etc complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Making good of wall surface with matching to existing surface complete all as specified and directed.(ii) PCC shall be measured and paid seperatelly. |
| 47 | S&F Powder coated aluminium louvered ventilators of section size 100mmx25mmx1.50mm including frosted glass fixed in half portion & adjustable type louvers in another half and stainless steel wire mesh fixed type on outside frame etc. complete all as specified and as directed by Engineer-in-Charge. |
| 48 | S&F in repairs powder coated aluminuium pipe 20 mm dia as in curtain rod fixed to brackets complete all as specified and as directed by Engineer-in-Charge. Note : brakets shall be measured and paid separately. |
| 49 | S & F in repairs powder coated aluminium brackets fancy type for curtain rods of 20mm dia complete all as specified and as directed by Engineer-in-Charge. . |
| 50 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and as directed by Engineer-in-Charge. |
| 51 | Taking up or down 15 mm bore steel tubing and connections including disconnection of fittings and cleaning for refixing where required complete all as specified and as directed by Engineer-in-Charge. |
| 52 | all as per Item No. 51 above but 20 mm dia pipe etc. |
| 53 | S & F 15 mm bore of pipe medium grade steel tubes, galvanised with & including all fittings and fixed complete to concealed walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge. |
| 54 | All as per serial item No. 53 above but except steel tubing. |
| 55 | S & F 20 mm bore of pipe medium grade steel tubes, galvanised with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-Charge. |
| 56 | S&F in repair rotational moulded polyethylene water storage tanks of capacity 500 ltr hoisted and fixed in position including 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed including taking down existing tank complete all as specified and as directed by Engineer-in-Charge. |
| 57 | S&F in repair Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe and fixed in repair complete all as specified and as directed by Engineer-in-Charge. |
| 58 | S & F in repairs 20mm dia bore Gun metal, globe or gate valves with Iron wheel head, screwed both ends for Iron pipes and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 59 | S & F in repair 15mm bore angle stop valves, fancy type CP, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed complete all as specified and as directed by Engineer-in-Charge. |
| 60 | S & F in repair stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed - bore dia of pipe 15 mm but fancy type with long shank and cup ( concealed type) complete all as specified and directed by Engineer in Charge. |
| 61 | S&F in repairs 15mm dia fancy type Bib taps, cast copper alloy CP with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 62 | S & F in repair,Chromium plated shower roses with or without swivel joints, 125mm size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-Charge. |
| 63 | S & F in repair PVC connections 15 mm size with PTMT nuts of 600 mm long complete all as specified and as directed by Engineer-in-Charge. |
| 64 | S&F in repair PVC (SWR) pipes 110mm dia ,single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and as directed by Engineer-in-Charge. |
| 65 | S&F in repairPVC (SWR) pipes 110mm dia ,single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-Charge. |
| 66 | S&F in repair,PVC (SWR) pipes 75 mm dia ,single socketed in any length with rubber ring joints fixed and laid in trenches or floor complete all as specified and as directed by Engineer-in-Charge. |
| 67 | S&F in repair,PVC (SWR) pipes 75 mm dia ,single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-Charge. |
| 68 | S&F in repair,PVC (SWR) bends any radius,for 110mm dia pipe complete all as specified and as directed by Engineer-in-Charge. |
| 69 | S&F in repair,PVC (SWR) bends any radius, 75mm dia pipe complete all as specified and as directed by Engineer-in-Charge. |
| 70 | S&F in repair,PVC (SWR) branch piece, single (single Y) equal or unequal,for 110mm dia pipe. |
| 71 | S&F in repair,PVC (SWR) branch piece, single (single Y) equal or unequal,for 75mm dia pipe complete all as specified and as directed by Engineer-in-Charge. |
| 72 | S&Fin repair,PVC (SWR), junction single, (Single T) equal or unequal,for 110mm dia pipe complete all as specified and as directed by Engineer-in-Charge. |
| 73 | S&F in repair,PVC (SWR), junction single, (Single T) equal or unequal,75mm dia pipe complete all as specified and as directed by Engineer-in-Charge. |
| 74 | S & F in repairs wash down water closet ( European type) excluding fixing bolts, flushing cistern, & flush pipe but including connecting to existing out let pipe etc complete all as specified and as directed by Engineer-in-Charge. |
| 75 | S & F in repair PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and as directed by Engineer-in-Charge. |
| 76 | S&F in repairs vitreous china wash basin white, flat back of size 450 x 300mm, excluding taps, waste chain & plug & porcelein stopper but including brackets, cutting for and pinning in ends of bracketscomplete all as specified and as directed by Engineer-in-Charge. |
| 77 | S & F in repairs 15mm dia brass CP Wall mixer for mixing hot & cold water screwed down for iron pipe and fixed of make CERA cat par No F 2010403 or techno commercially equivalent models in makes complete all as specified and as directed by Engineer-in-Charge. |
| 78 | S&F in repairs 15mm bore Brass CP basin mixer for mixing hot & Cold water screwed down for iron pipe complete all as directed by Engineer in charge. |
| 79 | S&F in repair ,stainless steel sink with drainage board, 1mm thick, kitchen or laboratory with plugs, washers and waste; including PVC waste pipe, bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed by Engineer-in-Charge. |
| 80 | S&F in repairs for 600mm x 450mm bevelled edge mirror of selected quality glass,mounted on 6mm thich AC Building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified and as directed by Engineer-in-Charge. |
| 81 | S&F in repairs tubular towel rail 20mm dia, D type 60cm long between flanges brass chromium plated complete all as specified and as directed by Engineer-in-Charge. |
| 82 | M&L in repair 100 mm dia cast iron floors trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4), complete all as specified and as directed by Engineer-in-Charge. |
| 83 | S&F in repairs 32 mm bore waste fittings, brass, chromium plated for sinks, basins etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge. |
| 84 | S&F in repairs grating square or circular 125mm dia of PTMT (minimum weight 100 gms, complete all as specified and as directed by Engineer-in-Charge. |
| 85 | Excavation in trenches not exceeding 1.50m wide and 1.50m depth for foundation, etc., for Shaft wells, Manholes etc not exceeding 10sqm on plan and not exceeding 1.50m in depth and getting out in soft / loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 86 | All as per Item No 85 above, but for depth exceeding 1.5m and not exceeding 3.0 m in soft/loose soil. |
| 87 | Returning filling in including spreading leveling watering well ramming in layers not exceeding 25cm thick with soil obtained from excavation complete all as specified and as directed by Engineer-in-Charge. |
| 88 | Removing excavated surplus soil not exceeding 50m and depositing where directed at a level exceeding 1.5m above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 89 | Demolition and breaking up drain pipes of 150 mm bore RCC/SGSW set in cement mortar including removing the debries to a distance n exc 100m,complete all as specified and as directed by Engineer-in-Charge. |
| 90 | All as per item No. 89 above but dia of pipe 200mm. |
| 91 | M&L for PCC C2 1;3:6 grade nominal mix using 40 mm graded stone aggregate as in concrete bed to drain pipes including packing under and haunching against sides of pipes with concrete after they are laid and bedded dia of pipe 150mm complete all as specified and as directed by Engineer-in-Charge. |
| 92 | All as per item No. 91 above but dia of pipe 200mm. |
| 93 | M&L in repair for 150mm dia RCC drain pipes class NP2 laid in trenches and jointed with in cement mortar complete all as specified and as directed by Engineer-in-Charge. |
| 94 | All as per item No. 93 above but dia of pipe 200mm. |
| 95 | M&L cutting to existing manholes 150mm dia for connecting new drain, making good to pipe and rendering, cutting out existing benchings for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for internal dia of pipe 150mm all as directed. |
| 96 | S&F in repair RCC precast Sewage manhole cover MD grade of size 450x900mm thickness 25-30 mm and set the same at the site including removing old from site in any position complete all as specified and directed by EIC |
| 97 | S&F in repair RCC Precast round Sewage manhole cover MD Grade of size 560-600mm dia thickness 50-60 mm heavy duty and set the same at the site including removing old from site in any position complete all as specified and directed by EIC |
| 98 | M&L for PCC 1:3:6 type C-2 , 75 mm thick as in plinth protection complete all as specified and as directed by Engineer-in-Charge. |
| 99 | M & L for 75mm PCC 1:4:8 type D2 ( 40 mm graded aggregates) as in sub base of floor complete all as specified and as directed by Engineer-in-Charge. |
| 100 | M&L in repair for Prepolished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in near cement slurry in floors with grey cement and pigment including 20mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 101 | S&F in repairs bathroom cabinet mirror (of approved pattern) of size 450mmx 350mm regular size with mirror and PVC shelves complete all as specified and directed by Engineer-in-Charge. |
| 102 | Dismantling structural steel work incl door ,gates but excluding framed truss complete all as specified and as directed by Engineer-in-Charge. |
| 103 | M&L for framed work as in doors or gates of angle Gde-Fe-290( Gde-E-165) or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed by Engineer-in-Charge. |
| 104 | S &F mild steel work in framed work such as grills framed guard bars, gratings, ladders etc with ends of bars shouldered and / or riveted or forged into spikes and similar work complete all as specified and as directed by Engineer-in-Charge. |
| 105 | S & F in repairs Plastic seat cover to EWC with aluminium hinging device complete all as specified and as directed by Engineer-in-Charge. |
| 106 | S&F in repairs fancy type heavy duty health faucet chromium plated (ABS Body) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook fixing to 15 mm bore of pipe complete all as specified and as directed by Engineer-in-Charge. |
| 107 | S&F in repairs fency type two way Bib cock 15mm dia , fancy type, chromium plated with capstan or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and suitable for 15 bore of pipe fixed complete all as specified and as directed by Engineer-in-Charge. |
| 108 | E/ M PORTION : Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed by Engineer-in-Charge. |
| 109 | M&L for point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through non metallic rigid PVC conduit and accessories concealed in walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes to provision of Modular switches to house switch/regulators etc including Modular Plate and Covers for one fan/light /bell point controlled by one switch/bell push complete all as specified and as directed by Engineer-in-Charge. |
| 110 | All as per item No.109 above for one 3 pin 5 Amps socket on same board controll with other switches on same board |
| 111 | All as per item No.109 above for one 3 pin 5 Amps socket on independent board |
| 112 | All as per Item No .109 above but with 2.5 Sqmm PVC insulated multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for Power Socket on independent board on the Concealed conduit complete all as specified and as directed by Engineer-in-Charge. |
| 113 | All as per Item No.109 above but with 4 Sqmm PVC insulated multistranded copper conductor with 4 sqmm cable as earth continuity conductor for Power Socket/AC/Geysers on independent board on the Concealed conduit complete all as specified and as directed by Engineer-in-Charge. |
| 114 | S&F for modular switch 1 way 6A 1 module complete all as specified and as directed by Engineer-in-Charge. |
| 115 | S&F for modular bell push 6A 1 module complete all as specified and as directed by Engineer-in-Charge. |
| 116 | S&F for modular socket 6A 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge. |
| 117 | S&F for modular socket 16A 2/3 pin combined 2 module complete all as specified and directed. |
| 118 | S&F for modular switch 1way 16A 1 module complete all as specified and as directed by Engineer-in-Charge. |
| 119 | S&F for Modular fan regulator, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 120 | S&F for electric bell Ding Dong, AC 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 121 | S&F for ceiling rose surface bakelite with three terminals complete all as specified and as directed by Engineer-in-Charge. |
| 122 | S&F for LED fitting for Bldg security, 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 / 66 protection complete. including conncting with 1.5 sq mm copper condector 3 core flexible cable from fitting connector to ceiling rose and fix on wall with clamps & nut bolts and necessary GI bracket made of 32 mm light grade GI pipe of 1 mtr lenth with necessary bendingcomplete all as specified and as directed by Engineer-in-Charge. |
| 123 | Taking down old unserviceable fitting and S & F wall mounted extruded aluminium housing high quality indoor batten LED tube 20 watt colour temperature 6500 K (4 feets long) lumen 2000 -3000, PF> 0.95, THD less 10% diffused connecting with suitable size of flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. |
| 124 | Taking down old unserviceable Recess mounting fitting of any type from any height and S & F high quality Recess/Surface mounting/POP ceilings mounted LED Flat panel 36 Watts size 2'x2' made of die cast aluminium housing with high efficient LEDs glare free opal diffiuser, with IP 20 protection complete as per site requirement connecting with suitable size of flexible copper wire complete all as specified and as directed by Engineer-in-Charge. Make : Hanolex/Jaquar/Havells.Note :- (i) The rates are inclusive of civil work (minor plastering, painting, false ceiling repair etc) wherever required for fixing the fittings to the roofs/POP celings/False ceilings. |
| 125 | Supply and fixing LED Light fitting mirror type with high output diffuser 2 feet , 1 X 10 watt 220 V AC decorative type with driver holder and LED lamp, Alluminium housing, including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. |
| 126 | Taking down old unserviceable wall bracket light fitting of any type & S & F wall mounted high quality indoor wall bracket light cylinderical/oval shape aesthetically designed fitting in wooden housing , glass and B22/E27 holder complete including inverter LED bulb B-22 cap with opal diffuser, IP-20 and inbuilt battery backup (LED INVERTER LIGHT 10W B22 CW IP) 10 watts including necessary eletric connection with PVC insulated multistranded copper cable of suitable size from ceiling rose to fitting terminal complete all as specified and as directed by Engineer-in-Charge. |
| 127 | Taking down unserviceable submain wiring andM&L for sub main wiring in repair but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 2.5 sqmm 1100 volt grade drawn into medium grade PVC Conduit concealed in walls of suitable size including 2.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface complete all as specified and as directed by Engineer-in-Charge. Make:- Polycab /Finolex/ RR Note: (For item 127, 128 & 129) Two run of single core PVC insulated multstranded copper conductor cable & one run of PVC insulated copper conductor cable green in colour with one run of PVC pipe medium grade shall be measure and paid one unit (RM) length. |
| 128 | All as above item no - 127 but of Cable size 4 sqmm 1100 volt grade drawn into PVC Conduit complete all as specified and as directed by Engineer-in-Charge. |
| 129 | Taking down unserviceable submain wiring and M&L for submain wiring in PVC conduit concealed in walls/ceilings with two runs of 10 sq mm and one runs of 10 sqmm for earth continuity 1100 v grade PVC insulated unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS 694) drawn through and including 25 mm dia PVC rigid connduit heavy grade ISI marked (IS 9537 Part III) includung accessories such as bends, supports etc complete all as specified and as directed by Engineer-in-Charge. Note: Two runs of 6 sq mm and one runs of 6 sqmm cable along with conduit shall be measured as one length. |
| 130 | S & F TPN distribution boards 100 Amps MCCB as incomer IP 43 Double door DB 04 way connect earth terminal with earthing complete all as specified and as directed by Engineer-in-Charge. |
| 131 | M & L For new MCCB 4 pole of capacity 100 Amps, 16 KA, 415 Volts complete all as specified and as directed by Engineer-in-Charge. |
| 132 | S & F MCB DB SPN 12 way of any size and capacity double door type horizontal with 200A busbar including disconnecting from mains and making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 133 | S & F MCB SP of capacity 5A - 32A \\"B' curve complete all as specified and as directed by Engineer-in-Charge. |
| 134 | S&F MCB, SPN (Double Pole) 32 amps, 240 Volts, 10 KA ‘’C” curve complete all as specified and as directed by Engineer-in-Charge. |
| 135 | Taking down unservicable earthing , M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt & charcoal including , excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board complete all as specified and as directed by Engineer-in-Charge. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. |
| 136 | Taking down old unsv exhaust fan and depositing it to MES store and Supply and fix Exhaust fan steel body AC single phase , 230 volts of size 300 mm sweep with blades and frame and louverscomplete all as specified and as directed by Engineer-in-Charge. Note : (i) To be Fixed in Kitchen/Toilet window (ii) The rates are inclusive of any civil work required to fix the exhaust fan. |
| 137 | Taking down old unsv ceiling fan and depositing it to MES store and Supply and fixing new ceiling fans complete with blades, down rods, electronic regulator/remote and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). complete all as specified and as directed by Engineer-in-Charge. |
| 138 | Taking down old unsv Wall fan and depositing it to MES store and Supply and fix Wall mounting fan of capacity 400mm sweep, double string, copper wounded, AC single Phase. 230V heavy duty with air delivery 65CMM, silent operation complete all as specified and as directed by Engineer-in-Charge. |
| 139 | S&F for single pole and neutral enclosure with a two pin and earth plug and socket complete with 20 Amp DP MCB complete all as specified and as directed by Engineer-in-Charge. |
| 140 | Taking down the existing serviceable kwh meter from site without any damage cleaning it properly and refixing the same with proper fixing arrangements near SPN DB of each guest room as directed by Engr-in-charge after complete all as specified and as directed by Engineer-in-Charge. |
| 141 | Taking down old unsv Geysers and depositing it to MES store and Supply and fix (Geyser) Water heater storage type of capacity 25 Liters vertical type wall mounted including 15/16 Amps plug top with suitable wall supports and for manual operation, digital temperature display, feather touch buttons, built in thermostat, auto shut off, powder coated single line weld container with PUF insulation, heating element capacity of 2 KW, voltage rating 230 Volt, frequency 50 Hz, 5 star rated with and including steel braided connecting hoses of required length for Hot and cold water pipe, connecting to CPVC and GI pipe complete all as specified and as directed by Engineer-in-Charge. Make: Havells/Jaquar/Crompton/Bajaj.Note :- (i) The rates are inclusive of all the minor spares (Fasteners, Nut bolts washers etc) required for making the geyser fully functional. |
| 142 | S&F for Hot water pillar taps 15 mm bore cast copper alloy with capstan heads, chromium plated, screwed down high pressure with lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by Engineer-in-Charge. |
| 143 | S&F for Stop Valves , cast copper alloy, screwed down , high pressure with crutch or butter fly handle , screwed both ends for iron pipe or for unions and fixed of size 15 mm complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail