| 1 | M&L for applying one coat of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 6 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 m the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying Apex/equivalent, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. Note: Work to be executed upto 15 m height or any situation. |
| 2 | M&L for applying two coat of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 6 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 m the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying Apex/equivalent should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. Note: Work to be executed upto 15 m height. |
| 3 | M&L for two coats of distemper oil emulsion white or tinted on walls over a coat of primer, including preperation of surfaces by washing, rubbing down, stopping and complete removal of old distempered surface etc. |
| 4 | M&L for 3mm thick wall care putty on wall. |
| 5 | M&L for one coat of distemper oil emulsion white or tinted on walls including preperation of surfaces by washing, rubbing down and stopping of distempered and painted surface. Note: Work to be executed upto 15 m height. |
| 6 | One coat of distemper oil emulsion white or tinted on ceilings, including preperation of surfaces by washing, rubbing down and stopping of distempered and painted surface, etc. Note: Work to be executed upto 15 m height |
| 7 | Taking down carefully (copper/aluminium) point wiring in ceiling and refixing the same in any position including replacing damaged material and lowering/rising the rod of ceiling fan if required complete and all as specified and directed. |
| 8 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified. |
| 9 | S&F hollow PVC Wall lining consisting of 5 to 7 mm thick Plain wood grain printed PVC sheet inclusive of solvent cement and fixing with 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall as per specifications includng taking down carefully (copper/aluminium) point wiring/ switch board in wall and ceiling and refixing the same in any position, complete as speified and directed. Note : Work to be executed upto 15 m height. |
| 10 | S&F suspended false ceiling system using T-grid. The size of grid shall be 600x600mm with GI frame work main runner 38x24x3600mm, cross tee 25x24x600mm/25x24x1200mm and wall angle 24x24x2540mm (thickness of the materail of 0.30mm) using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in the drop texture as per IS-2095, Part-I 1996, fixed in the T-grid suspended ceiling system duly susupended by 4mm dia GI bar hanged from the purlins of the roof with butter fly clips complete all as specified and directed. Note Work to be executed upto 15 m height or any situation. |
| 11 | Dismantling AC corrugated or semi corrugated sheets in wall cladding complete all as specified and directed. |
| 12 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mPa as in roof covering / cladding to wall, fixed with self tapping screws (at any height / any location ) complete all as specified and directed. |
| 13 | S&F for 2 mm fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof, wall (at any height / any location ) complete all as specified and directed. |
| 14 | S&F for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mPa as in roof covering / cladding to wall, ridges fixed with self tapping screws as specified.Note item 12 to 14: Work to be executed upto a ht of 15 m. |
| 15 | M&L for preparing old steel surfaces of any description over 10 cm in width or girth and applying two coats sythetic enamel paint with one coat of 'H' primer with necessary scaffolding and other safety arrangement to work at 15 m ht. |
| 16 | Dismantling PVC (SWR) pipe any size and in any position complete all as directed. |
| 17 | S&F for 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls |
| 18 | S&F for 110mm PVC (SWR) bends any radius |
| 19 | S&F for 110mm PVC (SWR) branch piece, single (single Y) equal or unequal |
| 20 | Excavation in post holes (or similar holes) each in n exc 0.5 cum getting out and removing surplus soil to a distance in n exc 50 m and making good surface in soft/loose soil complete all as specified and as directed. |
| 21 | Dismantling wrought iron or mild steel work of any description and in any position complete all as directed. |
| 22 | S&F rolled MS sections in roof trusses (framed), trussed, purlins, rafters, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc steel Fe-410-W (Gde E-250) Quality -A all as specified and directed. Note: Work to be executed upto 15 m height or any situation. |
| 23 | S&F steel work as in tabular trusses/supproting pipes etc complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St-240. |
| 24 | S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment. |
| 25 | M&L for pre-cast RCC 1:2:4 type B1 using 20mm graded stone aggregates as in cover slab/MH cover complete all as specified and directed. |
| 26 | M&L for TMT bars 5mm dia and over upto and including 10mm dia used in cover slab/MH cover, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. |
| 27 | Demolition of brick work or stone/boulder masonry, built in CM including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles. |
| 28 | M&L for brick work with fly ash bricks, straight or curved or plain exc 6m mean radius built in cement mortar 1:6. |
| 29 | M&L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate in foundation mass concrete and filling complete. |
| 30 | M&L for formwork using 40mm graded crushed stone aggregate, as in surface channels and drains etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 31 | Taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints,hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 32 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement on walls complete all as specified and as directed |
| 33 | M&L for Moorum / Red Bajri filling in floor or pavings, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering complete. |
| 34 | M&L for broken stone hard core of gauge n. exc. 63 mm deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rolled / rammed to a true surfaces complete. |
| 35 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) |
| 36 | M&L for PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base over rammed earth complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 37 | M&L for PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base over rammed earth complete all as specified and as directed. Please Enable Macros to View BoQ information |