| 1 | Taking down exsiting water proofing treatment incl PCC padding, plaster, etc complete necessary removal of debries from site outside MoD Land at Contarctor's own arrangement complete all as specified and directed. |
| 2 | M&L for cement concrete type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in foundation, filling, PCC padding in sunken floors/ roofs (for slope correction) and mass concrete complete all as specified and directed. |
| 3 | M&L 10mm thick cement plaster on fair face of concrete surface including repair of doubing roof surfaces in CM 1:3 finished even land smooth without using extra cement over complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately |
| 4 | M&L Preparing RCC roof slab top by wire brushing and cleaning the dust and forign materail etc complete and applying a coat of hot blown bitumen 85/25 grade @ 1.20kg/Sqm over a coat of bitumen primer @ 0.40 ltrs/Sqm and there after laying of a layer of APP based polymeric membrane (five layered with centre core as 100 microns high molecular high density polyethylene film) weighing 3kg/Sqm by propane torch application and will be laid as per MES SSR Pt-I para 11.43.2.2 with minium side lap 75 mm and end Lap of 150 mm bonded with hot blown bitumen 85/25 gde penetration @ 1.20 kg/sqm and blinded with fine sand in dry condition (pleable free) @ 0.50 kg/sqm dusted over the bitumen coat complete all as specified and directed. |
| 5 | M&L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished complete all as specified and directed. |
| 6 | M&L Providing PCC 1:2:4 type B1(using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clea span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throatin complete all as specified and directed. |
| 7 | M&L 20 mm thick cement plaster on fair face of concrete surface including repair of doubing roof/chajja/facia surfaces in CM 1:3 finished even land smooth without using extra cement over and applying two coat of cement base paint over a coat of primer after prepration of newly plastered surfaces up to Six story buildings of walls including scaffolding and all necessary items complete all as specified and directed.Note: WPC shall be measured and paid for seprately as supply only under respective item of sch A. |
| 8 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 9 | Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15cm thickness (above or below ground floors) complete all as specified and directed |
| 10 | M&L for 75mm thick PCC (Cement concrete) 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection finished even and fair and making 50mm deep joints at every 3 metre interval and at every corner and filling the joints with bitumen of grade 85/25 and sand mixture 1:3 complete all as specified and directed. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 12 | M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 13 | S&F Joist,channel,angle, or tee sections, fixed independently,without connecting plates, etc. (cut to ordinary lengths i.e within 20 mm of the length indicated, conforming to gde Fe 410-W (Gde E-250) Quality complete all as specified and directed. |
| 14 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness complete all as specified and directed. |
| 15 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and directed. |
| 16 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed. |
| 17 | S&F for framed work such as grills, gratings, etc.. With ends of bars shouldered and riveted, or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con-forming to Fe. 290. Gde-E-165. Note (ii) :- Work will be carried out upto 6 story in necessary scafolding and safety measures and labour insurance etc complete all as specified and directed. |
| 18 | M&L for Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 19 | Disconnecting & taking down existing water tank of capacity exc 250 liter and not exc. 500 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 500 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed. |
| 20 | Disconnecting & taking down existing water tank of capacity exc 500 liter and not exc. 1000 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 1000 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed. |
| 21 | Dismantling of cast iron, SGSW, PVC or reinforced concrete drain pipes (100 mm dia) jointed in neat cement mortar and taking out of trenches or floor or wall if required complete all as specified and directed. |
| 22 | S&F in PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in floor or fixed to wall complete all as specified and directed. |
| 23 | S&F in PVC (SWR) bend 110mm dia , any radius as required and jointed with approved adhesive complete all as specified and directed. |
| 24 | S&F in PVC (SWR) junction single (Single T) equal or un equal 110mm dia , any radius as required and jointed with approved adhesive complete all as specified and directed. |
| 25 | Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys , scrubing down with water etc, complete all as specified and directed. |
| 26 | M&L for Rendering 15 mm thick on fair faces of concrete /brick surface in cement mortar 1:6 finished fair and even as in wall complete all as specified and directed. |
| 27 | M&L for Rendering 10 mm thick on fair faces of concrete /brick surface in cement mortar 1:3 finished even and smooth without using extra cement as in ceiling and similar other work complete all as specified and directed. |
| 28 | M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for separately as supply only under respective item of sch A. |
| 29 | M&L two coats of oil bound distemper of required tint on newly plastered surfaces of wall and ceiling after prepration of surface and over a coat of 3 mm thick wall care puttty complete all as specified and directed. |
| 30 | M&L for preparation of newly plastered surface and applying two coats of cement base paint over a coat of suitable primer on walls complete all as specified and directed. |
| 31 | Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed |
| 32 | M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed. |
| 33 | Taking up or down steel tubing and connections 15mm bore complete all as specified and directed. |
| 34 | Taking up or down steel tubing and connections 20mm bore complete all as specified and directed. |
| 35 | S&F Steel water tubes, medium grade, ISI marked, galvanised, 15mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 36 | Description all as per item Srl No. 35.00 hefre in before but 20mm bore complete all as specified and directed. |
| 37 | S&F in repairs Stop Valve 20 mm, cast copper alloy, screwed down high pressure with crutch or butterfly handle etc complete all as specified and directed. |
| 38 | M&L for Dismantling of wall and ceiling boards any thickness including cover fillets complete all as specified and directed. |
| 39 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 40 | S&F Solid 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 41 | S&F in repair 18 to 20 mm thick solid PVC Board for cupboard/cabinet shutters with one side 1 mm thick printed PVC sheet other side plain PVC sheet of approved pattern as per specification and drawing and incl necessary beading in matching colour, magnetic ball catcher, 1 brass 2 lever lock of 50 mm complete all as specified and directed. |
| 42 | S&F in repair 18 to 20 mm thick solid PVC Board for cupboard/cabinet partitions/frame both side plain as per specification and drawing and necessary beading in matching colour complete all as specified and directed. |
| 43 | S&F brass handles, cast type, polished bright 100 mm size complete all as specified and directed. |
| 44 | S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flap (when open) 30 mm complete all as specified and directed. |
| 45 | S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting for cabinets fixed with screws complete all as specified and directed. |
| 46 | M&L for preparing old surfaces of walls plastered plastered by complete removal of existing treatment by electric grinder brooming down with steel or wire brush and scraping down smoke soot, moulds moss & efflorescent salt and trading oil and greasy spots , washing rubbing down and stopping of distempered and painted surface & removing all vegetation growth, nails and making good holes,cracks etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 5489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required hade (Company Depot Tinted) with silicon additive @ 1.43 litre/ 10 sqm over and complete all as specified and directed. |
| 47 | M&L for preparing old surfaces of walls plastered plastered by complete removal of existing treatment by electric grinder brooming down with steel or wire brush and scraping down smoke soot, moulds moss & efflorescent salt and trading oil and greasy spots , washing rubbing down and stopping of distempered and painted surface & removing all vegetation growth, nails and making good holes,cracks etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying two coat of approved shade of oil emulsion distemper, complete all as specified and directed |
| 48 | M&L for preparing of old painted wooden surfaces over 10cm width or girth and making good including knotting and stopping,cleaning etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying one coat of synthetic enamel paint on old prepared surfaces of wooden complete all as specified and directed. |
| 49 | M&L for preparing of old painted steel surfaces over 10cm width or girth and making good with & including by necessary red lead putty and make the surface smooth by rubbing with sand papers etc and applying one coat of synthetic enamel paint on old prepared surfaces of steel complete all as specified and directed. Please Enable Macros to View BoQ information |